{"product_id":"x20dm9324","title":"B\u0026R X20DM9324 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital inputs\/outputs\u003c\/p\u003e\n\u003cp\u003e8 digital inputs, sink connections 4 digital outputs, source connections 1-wire connections Configurable software input filter for entire module Integrated output protection This module is equipped with 8 inputs and 4 outputs for 1-wire connections.\u003c\/p\u003e\n\u003cp\u003eThe inputs are designed for sink connections, the outputs for source connections.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 8 digital inputs 24 VDC for 1-wire connections, 4 digital outputs 24 VDC for 1-wire connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator and software (output error status)\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.21 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.5 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x20B9\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = +0.21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤100 µs\u003c\/li\u003e\n\u003cli\u003eSoftware = Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Typ. 3.75 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eConnection type = 1-wire connections\u003c\/li\u003e\n\u003cli\u003eInput resistance = Typ. 6.4 kΩ\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003e0 → 1 = \u0026lt;300 µs\u003c\/li\u003e\n\u003cli\u003e1 → 0 = \u0026lt;300 µs\u003c\/li\u003e\n\u003cli\u003eSwitching frequency\u003c\/li\u003e\n\u003cli\u003eResistive load = Max. 500 Hz\u003c\/li\u003e\n\u003cli\u003eInductive load = See section \"Switching inductive loads\".\u003c\/li\u003e\n\u003cli\u003eVariant = Current-sourcing FET\u003c\/li\u003e\n\u003cli\u003eSwitching voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eNominal output current = 0.5 A\u003c\/li\u003e\n\u003cli\u003eTotal nominal current = 2 A\u003c\/li\u003e\n\u003cli\u003eConnection type = 1-wire connections\u003c\/li\u003e\n\u003cli\u003eOutput circuit = Source\u003c\/li\u003e\n\u003cli\u003eOutput protection = Thermal shutdown in the event of overcurrent or short circuit (see value \"Short-circuit peak current\") Internal freewheeling diode for switching inductive loads (see section \"Switching inductive loads\")\u003c\/li\u003e\n\u003cli\u003eDiagnostic status = Output monitoring with 10 ms delay\u003c\/li\u003e\n\u003cli\u003eLeakage current when the output is switched off = 5 µA\u003c\/li\u003e\n\u003cli\u003eR DS(on) = 210 mΩ\u003c\/li\u003e\n\u003cli\u003ePeak short-circuit current = \u0026lt;12 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on in the event of overload shutdown or short-circuit shutdown = Approx. 10 ms (depends on the module temperature)\u003c\/li\u003e\n\u003cli\u003eBraking voltage when switching off inductive loads = Typ. 50 VDC\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160980246781,"sku":"X20DM9324","price":332.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DM9324.jpg?v=1785730812","url":"https:\/\/shly-plc.com\/products\/x20dm9324","provider":"Lianyou PLC","version":"1.0","type":"link"}