{"product_id":"x20di2377","title":"B\u0026R X20DI2377 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital inputs\u003c\/p\u003e\n\u003cp\u003e2 digital inputs Sink connection 3-wire connections 2 counter inputs with 50 kHz counter frequency Gate measurement 24 VDC and GND for sensor supply Software input filter can be configured for entire module The module is equipped with two inputs for 3-wire connections.\u003c\/p\u003e\n\u003cp\u003eBoth inputs can be configured as event counters. Gate measurement is only ever possible on one channel.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 6-pin terminal blocks. If needed (e.g.\u003c\/p\u003e\n\u003cp\u003efor logistical reasons), the 12-pin terminal block can also be used.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 digital inputs 24 VDC for 3-wire connections, special functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.15 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.82 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1B8E\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤10 μs\u003c\/li\u003e\n\u003cli\u003eSoftware = Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Typ. 10.5 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eConnection type = 3-wire connections\u003c\/li\u003e\n\u003cli\u003eInput resistance = Typ. 2.23 kΩ\u003c\/li\u003e\n\u003cli\u003eAdditional functions = 50 kHz event counting, gate measurement\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEvent counters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eSignal form = Square wave pulse\u003c\/li\u003e\n\u003cli\u003eEvaluation = Each positive edge, cyclic counter\u003c\/li\u003e\n\u003cli\u003eInput frequency = Max. 50 kHz\u003c\/li\u003e\n\u003cli\u003eCounter 1 = Input 1\u003c\/li\u003e\n\u003cli\u003eCounter 2 = Input 2\u003c\/li\u003e\n\u003cli\u003eCounter frequency = Max. 50 kHz\u003c\/li\u003e\n\u003cli\u003eCounter size = 16-bit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGate time measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCounter frequency\u003c\/li\u003e\n\u003cli\u003eInternal = 48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz\u003c\/li\u003e\n\u003cli\u003eNumber of gate time measurements = 1\u003c\/li\u003e\n\u003cli\u003eSignal form = Square wave pulse\u003c\/li\u003e\n\u003cli\u003eEvaluation = Positive edge - Negative edge\u003c\/li\u003e\n\u003cli\u003eCounter size = 16-bit\u003c\/li\u003e\n\u003cli\u003eLength of pause between pulses = ≥100 µs\u003c\/li\u003e\n\u003cli\u003ePulse length = ≥20 µs\u003c\/li\u003e\n\u003cli\u003eSupported inputs = Input 1 or input 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSensor power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption = Max. 12 W\u003c\/li\u003e\n\u003cli\u003eVoltage = Module power supply minus voltage drop for short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVoltage drop for short-circuit protection at 500 mA = Max. 2 VDC\u003c\/li\u003e\n\u003cli\u003eSummation current = 0.5 A\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160980803837,"sku":"X20DI2377","price":460.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DI2377.jpg?v=1785723913","url":"https:\/\/shly-plc.com\/products\/x20di2377","provider":"Lianyou PLC","version":"1.0","type":"link"}