{"product_id":"x20dc1396","title":"B\u0026R X20DC1396 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Counter functions\u003c\/p\u003e\n\u003cp\u003e1 ABR incremental encoder 24 V 1 additional input e.g.\u003c\/p\u003e\n\u003cp\u003efor home enable switch 24 VDC and GND for encoder supply The module is equipped with 1 input for an ABR incremental encoder with 24 V encoder signal.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 1 ABR incremental encoder 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.01 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.4 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1BAC\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003cli\u003eType of signal lines = Shielded lines must be used for all signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤2 µs\u003c\/li\u003e\n\u003cli\u003eSoftware = -\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Approx. 3.3 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eConnection type = 3-wire connections\u003c\/li\u003e\n\u003cli\u003eInput resistance = 7.19 kΩ\u003c\/li\u003e\n\u003cli\u003eAdditional functions = Home enable switch\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eABR incremental encoder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤2 µs\u003c\/li\u003e\n\u003cli\u003eSoftware = -\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eEncoder inputs = 24 V, asymmetrical\u003c\/li\u003e\n\u003cli\u003eCounter size = 16\/32-bit\u003c\/li\u003e\n\u003cli\u003eInput frequency = Max. 100 kHz\u003c\/li\u003e\n\u003cli\u003eEvaluation = 4x\u003c\/li\u003e\n\u003cli\u003eEncoder power supply = Module-internal, max. 600 mA\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Approx. 1.3 mA\u003c\/li\u003e\n\u003cli\u003eInput resistance = 18.4 kΩ\u003c\/li\u003e\n\u003cli\u003eOverload characteristics of encoder power supply = Short-circuit proof, overload-proof\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between encoder and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Bus isolated from encoder and reference enable switch Encoder not isolated from reference enable switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160981000445,"sku":"X20DC1396","price":406.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DC1396.jpg?v=1785723890","url":"https:\/\/shly-plc.com\/products\/x20dc1396","provider":"Lianyou PLC","version":"1.0","type":"link"}