{"product_id":"x20cp1483","title":"B\u0026R X20CP1483 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC systems \u0026gt; X20 System \u0026gt; X20 PLC\u003c\/p\u003e\n\u003cp\u003eIntel x86-based, 100 MHz-compatible CPU with integrated I\/O processor Onboard Ethernet, POWERLINK and USB 1 slot for modular interface expansion CompactFlash as removable application memory Fanless The Intel x86-based, 100 MHz-compatible X20CP1483 represents the entry-level X20 controllers.\u003c\/p\u003e\n\u003cp\u003eWith an optimum price\/performance ratio, it has the same basic features as all of the larger controllers.\u003c\/p\u003e\n\u003cp\u003eOnboard Ethernet and USB are standard.\u003c\/p\u003e\n\u003cp\u003eIn addition, the controller has a POWERLINK connection for hard real-time communication.\u003c\/p\u003e\n\u003cp\u003eAnother slot is available for an additional interface module to increase flexibility.\u003c\/p\u003e\n\u003cp\u003eThe only difference between the two variants X20CP1483 and X20CP1483-1 is the size of the SDRAM.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces = 1x RS232, 1x Ethernet, 1x POWERLINK (V1\/V2), 2x USB, 1x X2X Link\u003c\/li\u003e\n\u003cli\u003eSystem module = Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eBattery = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eCPU function = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eCompactFlash = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eEthernet = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePOWERLINK = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eTemperature = Yes, using software register\u003c\/li\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eACOPOS support = Yes\u003c\/li\u003e\n\u003cli\u003eVisual Components support = Yes\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.6 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA239\u003c\/li\u003e\n\u003cli\u003eCooling = Fanless\u003c\/li\u003e\n\u003cli\u003eStatus indicators = CPU function, Ethernet, POWERLINK, CompactFlash, battery\u003c\/li\u003e\n\u003cli\u003ePower consumption without memory card, interface module and USB = 6 W\u003c\/li\u003e\n\u003cli\u003ePower consumption for X2X Link power supply = 1.42 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU and X2X Link power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 2.2 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eX2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 7 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply - General information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOverload = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eI\/O supply - I\/O power supply = No\u003c\/li\u003e\n\u003cli\u003eCPU\/X2X Link supply - CPU\/X2X Link power supply = Yes\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Overload, operating status, module status, RS232 data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProcessor\u003c\/li\u003e\n\u003cli\u003eType = x86 100 (compatible)\u003c\/li\u003e\n\u003cli\u003eClock frequency = 100 MHz\u003c\/li\u003e\n\u003cli\u003eL2 cache = -\u003c\/li\u003e\n\u003cli\u003eL1 cache for data and program code = 16 kB\u003c\/li\u003e\n\u003cli\u003eData buffering\u003c\/li\u003e\n\u003cli\u003eBattery monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eLithium battery = At least 3 years\u003c\/li\u003e\n\u003cli\u003eStandard memory\u003c\/li\u003e\n\u003cli\u003eRAM = 32 MB SDRAM\u003c\/li\u003e\n\u003cli\u003eUser RAM = 128 kB SRAM\u003c\/li\u003e\n\u003cli\u003eCompactFlash slot = 1\u003c\/li\u003e\n\u003cli\u003eReal-time clock = Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C\u003c\/li\u003e\n\u003cli\u003eFloating point unit (FPU) = Yes\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O processor = Processes I\/O data points in the background\u003c\/li\u003e\n\u003cli\u003eModular interface slots = 1\u003c\/li\u003e\n\u003cli\u003eRemanent variables = Max. 32 kB\u003c\/li\u003e\n\u003cli\u003eShortest task class cycle time = 1 ms\u003c\/li\u003e\n\u003cli\u003eTypical instruction cycle time = 0.09 μs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface IF1\u003c\/li\u003e\n\u003cli\u003eSignal = RS232\u003c\/li\u003e\n\u003cli\u003eVariant = Connection via 12-pin terminal block X20TB12\u003c\/li\u003e\n\u003cli\u003eMax. distance = 900 m\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 115.2 kbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF2\u003c\/li\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 10BASE-T\/100BASE-TX\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eSignal = Ethernet\u003c\/li\u003e\n\u003cli\u003eVariant = 1x RJ45 shielded\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 10\/100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF3\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eFull-duplex = POWERLINK mode: No \/ Ethernet mode: Yes\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK (V1\/V2) managing or controlled node\u003c\/li\u003e\n\u003cli\u003eType = Type 4\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF4\u003c\/li\u003e\n\u003cli\u003eType = USB 1.1\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003cli\u003eMax. output current = 0.5 A\u003c\/li\u003e\n\u003cli\u003eInterface IF5\u003c\/li\u003e\n\u003cli\u003eInterface IF6\u003c\/li\u003e\n\u003cli\u003eFieldbus = X2X Link master\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160998760701,"sku":"X20CP1483","price":3769.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CP1483.jpg?v=1785723720","url":"https:\/\/shly-plc.com\/products\/x20cp1483","provider":"Lianyou PLC","version":"1.0","type":"link"}