{"product_id":"x20cp1382","title":"B\u0026R X20CP1382 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eIntel x86 400 MHz compatible with integrated I\/O processor Ethernet, POWERLINK with poll-response chaining and onboard USB 1 slot for modular interface expansion 30 digital inputs\/outputs and 2 analog inputs integrated in the device 2 GB onboard flash drive 256 MB DDR3 SDRAM Fanless No battery Backed-up real-time clock The X20 Compact controller series is characterized by 3 integrated I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe device is equipped with 30 different digital inputs\/outputs and 2 analog inputs .\u003c\/p\u003e\n\u003cp\u003e1 analog input can be used for Pt1000 resistance temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe X20CP1382 is equipped with an Intel x86 400 MHz compatible processor, 256 MB RAM and 2 GB built-in flash drive.\u003c\/p\u003e\n\u003cp\u003eThe FRAM for storing remanent variables has 32 kB available.\u003c\/p\u003e\n\u003cp\u003eA fanless and battery-free design ensures maintenance-free operation.\u003c\/p\u003e\n\u003cp\u003eThe controller is equipped with Ethernet, 2x USB and an RS232 interface.\u003c\/p\u003e\n\u003cp\u003eIn addition, POWERLINK and CAN bus are available as integrated interfaces.\u003c\/p\u003e\n\u003cp\u003eFor additional fieldbus connections, each controller can be expanded with an interface module from the X20 standard portfolio.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces = 1x RS232, 1x Ethernet, 1x POWERLINK, 2x USB, 1x X2X Link, 1x CAN bus\u003c\/li\u003e\n\u003cli\u003eSystem module = Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eOutputs = Digital outputs: Yes, using LED status indicator and software (output error status)\u003c\/li\u003e\n\u003cli\u003eCPU function = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eCAN bus data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eInputs = Analog inputs: Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eEthernet = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eI\/O power supply = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePOWERLINK = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eSupply voltage monitoring = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eTemperature = Yes, using software register\u003c\/li\u003e\n\u003cli\u003eTerminating resistor = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eController redundancy = No\u003c\/li\u003e\n\u003cli\u003eACOPOS support = Yes\u003c\/li\u003e\n\u003cli\u003ereACTION-capable I\/O channels = No\u003c\/li\u003e\n\u003cli\u003eVisual Components support = Yes\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 2.3 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xDABB\u003c\/li\u003e\n\u003cli\u003eCooling = Fanless\u003c\/li\u003e\n\u003cli\u003eStatus indicators = CPU function, Ethernet, POWERLINK, RS232, CAN bus, CAN bus terminating resistor, PLC power supply, I\/O power supply, I\/O function per channel\u003c\/li\u003e\n\u003cli\u003ePower consumption without interface module and USB = 5.5 W\u003c\/li\u003e\n\u003cli\u003ePower consumption for X2X Link power supply = 0.8 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003cli\u003eType of signal lines = Shielded lines must be used for all high-speed digital inputs\/outputs, line length: Max. 20 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU and X2X Link power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 1 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eX2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 2 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProcessor\u003c\/li\u003e\n\u003cli\u003eL1 cache\u003c\/li\u003e\n\u003cli\u003eData code = 16 kB\u003c\/li\u003e\n\u003cli\u003eProgram code = 16 kB\u003c\/li\u003e\n\u003cli\u003eType = Vx86EX\u003c\/li\u003e\n\u003cli\u003eClock frequency = 400 MHz\u003c\/li\u003e\n\u003cli\u003eL2 cache = 128 kB\u003c\/li\u003e\n\u003cli\u003eStandard memory\u003c\/li\u003e\n\u003cli\u003eRAM = 256 MB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eApplication memory\u003c\/li\u003e\n\u003cli\u003eWritable data amount\u003c\/li\u003e\n\u003cli\u003eGuaranteed = 40 TB\u003c\/li\u003e\n\u003cli\u003eResults for 5 years = 21.9 GB\/day\u003c\/li\u003e\n\u003cli\u003eType = 2 GB eMMC flash memory\u003c\/li\u003e\n\u003cli\u003eData retention = 10 years\u003c\/li\u003e\n\u003cli\u003eGuaranteed erase\/write cycles = 20,000\u003c\/li\u003e\n\u003cli\u003eError-correcting code (ECC) = Yes\u003c\/li\u003e\n\u003cli\u003eReal-time clock = Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, -18 to 28 ppm accuracy at 25°C\u003c\/li\u003e\n\u003cli\u003eFloating point unit (FPU) = Yes\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O processor = Processes I\/O data points in the background\u003c\/li\u003e\n\u003cli\u003eModular interface slots = 1\u003c\/li\u003e\n\u003cli\u003eRemanent variables = 32 kB FRAM, retention \u0026gt;10 years\u003c\/li\u003e\n\u003cli\u003eShortest task class cycle time = 1 ms\u003c\/li\u003e\n\u003cli\u003eTypical instruction cycle time = 0.0199 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface IF1\u003c\/li\u003e\n\u003cli\u003eSignal = RS232\u003c\/li\u003e\n\u003cli\u003eVariant = Connection via 16-pin terminal block X20TB1F\u003c\/li\u003e\n\u003cli\u003eMax. distance = 900 m\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 115.2 kbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF2\u003c\/li\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 10BASE-T\/100BASE-TX\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eSignal = Ethernet\u003c\/li\u003e\n\u003cli\u003eVariant = 1x RJ45 shielded\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 10\/100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF3\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eFull-duplex = POWERLINK mode: No \/ Ethernet mode: Yes\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK managing or controlled node\u003c\/li\u003e\n\u003cli\u003eType = Type 4\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF4\u003c\/li\u003e\n\u003cli\u003eType = USB 1.1\/2.0\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160998695165,"sku":"X20CP1382","price":2046.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CP1382.jpg?v=1785723712","url":"https:\/\/shly-plc.com\/products\/x20cp1382","provider":"Lianyou PLC","version":"1.0","type":"link"}