{"product_id":"x20cm4810","title":"B\u0026R X20CM4810 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Other functions\u003c\/p\u003e\n\u003cp\u003e4-channel vibration measurement and analysis module 24-bit resolution at 51.562 kHz IEPE supply Internal calculation of an extensive range of condition parameters Data buffer upload This compact module provides a system for measuring and analyzing vibrations for use in applications such as condition monitoring for machinery and equipment.\u003c\/p\u003e\n\u003cp\u003eThe measurement unit consists of 4 vibration inputs with 24-bit converter resolution and a sampling frequency of 51.562 kHz.\u003c\/p\u003e\n\u003cp\u003eEach of the inputs has a separately activated constant current source to supply IEPE sensors.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning algorithms integrated in the module include configurable high and low-pass filters, an envelope curve generator and a Fourier transform, among many others.\u003c\/p\u003e\n\u003cp\u003eVarious characteristic values and configurable frequency bands are available to ensure seamless signal evaluation.\u003c\/p\u003e\n\u003cp\u003eThe module-internal calculation minimizes the load on the bus and PLC.\u003c\/p\u003e\n\u003cp\u003eWhether used for traditional condition monitoring or as a means of process optimization, the maximum evaluable frequency of 10 kHz and maximum frequency resolution of under 63 mHz make it suitable for almost any application.\u003c\/p\u003e\n\u003cp\u003eIf desired, it can also be used as a standard input module.\u003c\/p\u003e\n\u003cp\u003eThe ability to upload all values in the time and frequency domain also allow measurements to be evaluated externally or archived.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = X20 4-channel analog input module for vibration measurement and analysis of condition monitoring tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.01 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 2.5 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC ±20%\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xC8F9\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Run, error, vibration inputs 1 to 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOpen-circuit detection\u003c\/li\u003e\n\u003cli\u003ePer channel = Yes\u003c\/li\u003e\n\u003cli\u003eAt minimum supply voltage = Starting at 17 V (or greater) for more than 1 ms\u003c\/li\u003e\n\u003cli\u003eAt nominal supply voltage = Starting at 21.3 V (or greater) for more than 1 ms\u003c\/li\u003e\n\u003cli\u003eAt maximum supply voltage = Starting at 25.5 V (or greater) for more than 1 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 4\u003c\/li\u003e\n\u003cli\u003eInput type = IEPE sensor: Acceleration\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 24-bit\u003c\/li\u003e\n\u003cli\u003ePermissible input signal = ±10 VAC\u003c\/li\u003e\n\u003cli\u003eConversion procedure = Sigma-delta\u003c\/li\u003e\n\u003cli\u003eType = Vibration input\u003c\/li\u003e\n\u003cli\u003eSampling frequency = 51.5625 kHz\u003c\/li\u003e\n\u003cli\u003eInput high pass cutoff frequency = 34 mHz\u003c\/li\u003e\n\u003cli\u003eInput low pass cutoff frequency = 19.75 kHz\u003c\/li\u003e\n\u003cli\u003eDownsampling = 200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz (configurable)\u003c\/li\u003e\n\u003cli\u003eFrequency resolution of spectra = 0.0629 Hz, 0.1574 Hz, 0.3147 Hz, 0.6294 Hz, 1.5736 Hz, 3.1471 Hz\u003c\/li\u003e\n\u003cli\u003eSensor power supply = IEPE, 5 mA constant current source (4.9 - 5.5 mA), can be switched off for each channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 45°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM31 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 25 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160982671613,"sku":"X20CM4810","price":1298.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CM4810.jpg?v=1785723662","url":"https:\/\/shly-plc.com\/products\/x20cm4810","provider":"Lianyou PLC","version":"1.0","type":"link"}