{"product_id":"x20bt9100","title":"B\u0026R X20BT9100 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Bus receivers and transmitters\u003c\/p\u003e\n\u003cp\u003eX2X Link bus transmitter For seamless expansion of the system Up to 100 m segment length Supply for internal I\/O power supply Operation only on the rightmost slot The bus transmitter is used for seamless expansion of the X20 system.\u003c\/p\u003e\n\u003cp\u003eStations can be up to 100 m apart.\u003c\/p\u003e\n\u003cp\u003eThe bus transmitter module is only permitted to be operated with a bus module where the internal I\/O power supply is connected through (e.g.\u003c\/p\u003e\n\u003cp\u003eX20BM11).\u003c\/p\u003e\n\u003cp\u003eIf the supply is used for the internal I\/O power supply, this potential group is not permitted to be supplied by any other module.\u003c\/p\u003e\n\u003cp\u003eAn I\/O module with bus module X20BM01 must be used to isolate the potential group.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBus transmitter = X2X Link bus transmitter with supply for I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eX2X bus function = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O\u003c\/li\u003e\n\u003cli\u003eAs bus transmitter = 0.1 W\u003c\/li\u003e\n\u003cli\u003eAdditionally as supply module = 0.6 W\u003c\/li\u003e\n\u003cli\u003eBus = 0.5 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1BC2\u003c\/li\u003e\n\u003cli\u003eStatus indicators = X2X bus function, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eBehavior on short circuit = Required line fuse\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 or X20BM15 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160983490813,"sku":"X20BT9100","price":357.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BT9100.jpg?v=1785730871","url":"https:\/\/shly-plc.com\/products\/x20bt9100","provider":"Lianyou PLC","version":"1.0","type":"link"}