{"product_id":"x20bc00g3","title":"B\u0026R X20BC00G3 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Bus controllers\u003c\/p\u003e\n\u003cp\u003eFieldbus: EtherCAT Auto-configuration of I\/O modules I\/O configuration and firmware update via the fieldbus (FoE) Full support of the modular slice concept via CoE (CANopen over EtherCAT) Configurable I\/O cycle (0.2 to 4 ms) Synchronization between the fieldbus and X2X Link EtherCAT is an Ethernet-based fieldbus developed by Beckhoff.\u003c\/p\u003e\n\u003cp\u003eThis protocol is suitable for both hard and soft real-time requirements in automation technology.\u003c\/p\u003e\n\u003cp\u003eIn addition to a ring structure, which becomes logically necessary because of the summation frame telegram used, the EtherCAT technology also physically supports topologies such as line, tree, star (limited) and combinations of these topologies.\u003c\/p\u003e\n\u003cp\u003eB\u0026amp;R's X20BC80G3 (expandable bus controller module) and X20HB88G0 (standalone junction base module) are available for implementing these topologies.\u003c\/p\u003e\n\u003cp\u003eEtherCAT slave devices take the data designated for them from a telegram as it is passing through the device.\u003c\/p\u003e\n\u003cp\u003eInput data is also added to the telegram as it is passing through.\u003c\/p\u003e\n\u003cp\u003eThe bus controller allows X2X Link I\/O modules to be coupled to EtherCAT and operated on any EtherCAT master system.\u003c\/p\u003e\n\u003cp\u003eA transition between IP20 and IP67 protection outside of the control cabinet is possible by arranging X20, X67 or XV modules one after the other as needed at distances up to 100 m.\u003c\/p\u003e\n\u003cp\u003eMaster systems without FoE (File access over EtherCAT) support require an appropriate configuration tool to transfer the configuration (optional).\u003c\/p\u003e\n\u003cp\u003eWith multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).\u003c\/p\u003e\n\u003cp\u003eAll other function models are supported when configured accordingly in Automation Studio V4.3 or later.\u003c\/p\u003e\n\u003cp\u003eAutomation Studio kann kostenlos von der B\u0026amp;R Webseite www.br-automation.com heruntergeladen werden.\u003c\/p\u003e\n\u003cp\u003eDie Evaluierungslizenz darf unentgeltlich zur Erstellung vollständiger Konfigurationen der Feldbus Bus Controller benützt werden.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBus controller = EtherCAT slave\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule status = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBus function = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 1.68 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xAC23\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Module status, bus function\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eMin. cycle time\u003c\/li\u003e\n\u003cli\u003eFieldbus = 200 μs\u003c\/li\u003e\n\u003cli\u003eX2X Link = 200 μs\u003c\/li\u003e\n\u003cli\u003eFieldbus = EtherCAT slave\u003c\/li\u003e\n\u003cli\u003eExecution = 2x shielded RJ45\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eHub propagation delay = 750 ns\u003c\/li\u003e\n\u003cli\u003eSynchronization between bus systems possible = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = EtherCAT isolated from bus and I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = 0 to 55°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = 0 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB80 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 37.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160984965373,"sku":"X20BC00G3","price":813.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BC00G3.jpg?v=1785723555","url":"https:\/\/shly-plc.com\/products\/x20bc00g3","provider":"Lianyou PLC","version":"1.0","type":"link"}