{"product_id":"x20at2311","title":"B\u0026R X20AT2311 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Temperature measurement\u003c\/p\u003e\n\u003cp\u003e2 inputs for resistance temperature measurement PT100 sensor Direct resistance measurement 4-wire measurement Configurable filter time The module is equipped with 2 inputs for PT100 4-line resistance temperature measurement.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 inputs for PT100 resistance temperature measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.35 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.85 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA4AA\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResistance measurement temperature inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion time\u003c\/li\u003e\n\u003cli\u003e1000 Hz filter = 1 ms for all inputs\u003c\/li\u003e\n\u003cli\u003e50 Hz filter = 20 ms for all inputs\u003c\/li\u003e\n\u003cli\u003eMax. error at 25°C\u003c\/li\u003e\n\u003cli\u003eGain = ±0.0059%\u003c\/li\u003e\n\u003cli\u003eOffset = ±0.0015%\u003c\/li\u003e\n\u003cli\u003eTemperature measurement monitoring\u003c\/li\u003e\n\u003cli\u003eRange undershoot = 0x80000001\u003c\/li\u003e\n\u003cli\u003eRange overshoot = 0x7FFFFFFF\u003c\/li\u003e\n\u003cli\u003eOpen circuit = 0x7FFFFFFF\u003c\/li\u003e\n\u003cli\u003eGeneral fault = 0x80000000\u003c\/li\u003e\n\u003cli\u003eOpen inputs = 0x7FFFFFFF\u003c\/li\u003e\n\u003cli\u003eResistance measurement monitoring\u003c\/li\u003e\n\u003cli\u003eRange overshoot = 0xFFFFFFFF\u003c\/li\u003e\n\u003cli\u003eOpen circuit = 0xFFFFFFFF\u003c\/li\u003e\n\u003cli\u003eInput = Resistance measurement with constant current supply for 4-wire connections\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 24-bit\u003c\/li\u003e\n\u003cli\u003eFilter time = Configurable between 1 ms and 400 ms\u003c\/li\u003e\n\u003cli\u003eConversion procedure = Sigma-delta\u003c\/li\u003e\n\u003cli\u003eOutput format = DINT or UDINT for resistance measurement\u003c\/li\u003e\n\u003cli\u003eTemperature measurement range = -200 to 850°C\u003c\/li\u003e\n\u003cli\u003eResistance measurement range = 0.5 to 390 Ω\u003c\/li\u003e\n\u003cli\u003eTemperature sensor resolution = 1 LSB = 0.001°C\u003c\/li\u003e\n\u003cli\u003eResistance measurement resolution = 0.001 Ω\u003c\/li\u003e\n\u003cli\u003eInput filter = First-order low-pass filter \/ cutoff frequency 1050 Hz\u003c\/li\u003e\n\u003cli\u003eSensor standard = EN 60751\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and channel = 500 V eff\u003c\/li\u003e\n\u003cli\u003eLinearization method = Internal\u003c\/li\u003e\n\u003cli\u003eMeasuring current = 1 mA\u003c\/li\u003e\n\u003cli\u003eTemperature sensor normalization = -200.0 to 850.0°C\u003c\/li\u003e\n\u003cli\u003eReference = 1568 Ω ±0.1%\u003c\/li\u003e\n\u003cli\u003ePermissible input signal = Short-term max. 28.8 V\u003c\/li\u003e\n\u003cli\u003eMax. gain drift = ±0.00065%\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift = ±0.000025%\/°C\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.001%\u003c\/li\u003e\n\u003cli\u003eStandardized range of values for resistance measurement = 0.5 Ω to 390 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from channel and bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160986046717,"sku":"X20AT2311","price":380.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20AT2311.jpg?v=1785723469","url":"https:\/\/shly-plc.com\/products\/x20at2311","provider":"Lianyou PLC","version":"1.0","type":"link"}