{"product_id":"x20ao2437","title":"B\u0026R X20AO2437 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Analog outputs\u003c\/p\u003e\n\u003cp\u003e2 analog current outputs Electrically isolated analog channels 16-bit digital converter resolution The module is equipped with 2 current outputs with 16-bit digital converter resolution.\u003c\/p\u003e\n\u003cp\u003eThe 2 channels are electrically isolated from each other.\u003c\/p\u003e\n\u003cp\u003eThe user can select between the 3 output ranges 4 to 20 mA , 0 to 20 mA and 0 to 24 mA .\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 analog outputs 4 to 20 mA, 0 to 20 mA or 0 to 24 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.05 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.6 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xB785\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. error\u003c\/li\u003e\n\u003cli\u003eGain\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA = ±0.025%\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA = ±0.022%\u003c\/li\u003e\n\u003cli\u003e0 to 24 mA = ±0.02%\u003c\/li\u003e\n\u003cli\u003eOffset\u003c\/li\u003e\n\u003cli\u003eOutput format\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA = INT 0x0000 to 0x7FFF \/ 1 LSB = 0x0001 = 488.281 nA\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA = INT 0x0000 to 0x7FFF \/ 1 LSB = 0x0001 = 610.352 nA UINT 0x0000 to 0xFFFF \/ 1 LSB = 0x0001 = 305.176 nA\u003c\/li\u003e\n\u003cli\u003e0 to 24 mA = INT 0x0000 to 0x5DC0 \/ 1 LSB = 0x0001 = 1000 nA\u003c\/li\u003e\n\u003cli\u003eMax. gain drift\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA = ±0.0055%\/°C\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA = ±0.005%\/°C\u003c\/li\u003e\n\u003cli\u003e0 to 24 mA = ±0.005%\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA = ±0.0035%\/°C\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA = ±0.002%\/°C\u003c\/li\u003e\n\u003cli\u003e0 to 24 mA = ±0.002%\/°C\u003c\/li\u003e\n\u003cli\u003eError caused by load change\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA = 0.14%\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA = 0.1%\u003c\/li\u003e\n\u003cli\u003e0 to 24 mA = 0.1%\u003c\/li\u003e\n\u003cli\u003eTest voltage\u003c\/li\u003e\n\u003cli\u003eChannel - Channel = 1000 VAC\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = 1000 VAC\u003c\/li\u003e\n\u003cli\u003eChannel - Ground = 1000 VAC\u003c\/li\u003e\n\u003cli\u003eOutput = 4 to 20 mA, 0 to 20 mA or 0 to 24 mA configurable using software\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 16-bit\u003c\/li\u003e\n\u003cli\u003eSettling time on output change over entire range = 2 ms to 20 s, configurable using software\u003c\/li\u003e\n\u003cli\u003eData output rate = 1 ms without ramp\u003c\/li\u003e\n\u003cli\u003eOutput protection = Short-circuit proof, overvoltage protection (up to 30 VDC)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit detection = Yes, using hardware and software\u003c\/li\u003e\n\u003cli\u003eData format = INT\u003c\/li\u003e\n\u003cli\u003eLoad per channel = Max. 600 Ω\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes, continuous\u003c\/li\u003e\n\u003cli\u003eOutput filter = Active second-order low-pass filter \/ Cutoff frequency 4 kHz Configurable slew rate\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.003%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from channel and bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160986636541,"sku":"X20AO2437","price":1663.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20AO2437.jpg?v=1785723430","url":"https:\/\/shly-plc.com\/products\/x20ao2437","provider":"Lianyou PLC","version":"1.0","type":"link"}