{"product_id":"x20ai2622","title":"B\u0026R X20AI2622 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Analog inputs\u003c\/p\u003e\n\u003cp\u003e2 analog inputs Either current or voltage signal possible 13-bit digital converter resolution The module is equipped with 2 inputs with 13-bit (including sign) digital converter resolution.\u003c\/p\u003e\n\u003cp\u003eIt is possible to select between the current and voltage signal using different terminals.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 6-pin terminal blocks. If needed (e.g.\u003c\/p\u003e\n\u003cp\u003efor logistical reasons), the 12-pin terminal block can also be used.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 analog inputs ±10 V or 0 to 20 mA \/ 4 to 20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eChannel type = Yes, using software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.01 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.8 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1B9E\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital converter resolution\u003c\/li\u003e\n\u003cli\u003eVoltage = ±12-bit\u003c\/li\u003e\n\u003cli\u003eCurrent = 12-bit\u003c\/li\u003e\n\u003cli\u003eOutput format\u003c\/li\u003e\n\u003cli\u003eData type = INT\u003c\/li\u003e\n\u003cli\u003eVoltage = INT 0x8001 - 0x7FFF \/ 1 LSB = 0x0008 = 2.441 mV\u003c\/li\u003e\n\u003cli\u003eCurrent = INT 0x0000 - 0x7FFF \/ 1 LSB = 0x0008 = 4.883 µA\u003c\/li\u003e\n\u003cli\u003eInput impedance in signal range\u003c\/li\u003e\n\u003cli\u003eVoltage = 20 MΩ\u003c\/li\u003e\n\u003cli\u003eCurrent = -\u003c\/li\u003e\n\u003cli\u003eLoad\u003c\/li\u003e\n\u003cli\u003eVoltage = -\u003c\/li\u003e\n\u003cli\u003eCurrent = \u0026lt;400 Ω\u003c\/li\u003e\n\u003cli\u003ePermissible input signal\u003c\/li\u003e\n\u003cli\u003eVoltage = Max. ±30 V\u003c\/li\u003e\n\u003cli\u003eCurrent = Max. ±50 mA\u003c\/li\u003e\n\u003cli\u003eMax. error\u003c\/li\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eGain = 0.08%\u003c\/li\u003e\n\u003cli\u003eOffset = 0.015%\u003c\/li\u003e\n\u003cli\u003eCurrent\u003c\/li\u003e\n\u003cli\u003eGain = 0 to 20 mA = 0.08% \/ 4 to 20 mA = 0.1%\u003c\/li\u003e\n\u003cli\u003eOffset = 0 to 20 mA = 0.03% \/ 4 to 20 mA = 0.16%\u003c\/li\u003e\n\u003cli\u003eMax. gain drift\u003c\/li\u003e\n\u003cli\u003eVoltage = 0.006%\/°C\u003c\/li\u003e\n\u003cli\u003eCurrent = 0 to 20 mA = 0.009 %\/°C 4 to 20 mA = 0.0113 %\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift\u003c\/li\u003e\n\u003cli\u003eVoltage = 0.002%\/°C\u003c\/li\u003e\n\u003cli\u003eCurrent = 0 to 20 mA = 0.004 %\/°C 4 to 20 mA = 0.005 %\/°C\u003c\/li\u003e\n\u003cli\u003eCommon-mode rejection\u003c\/li\u003e\n\u003cli\u003eDC = 70 dB\u003c\/li\u003e\n\u003cli\u003e50 Hz = 70 dB\u003c\/li\u003e\n\u003cli\u003eNonlinearity\u003c\/li\u003e\n\u003cli\u003eVoltage = \u0026lt;0.025%\u003c\/li\u003e\n\u003cli\u003eCurrent = \u0026lt;0.05%\u003c\/li\u003e\n\u003cli\u003eInput = ±10 V or 0 to 20 mA \/ 4 to 20 mA, via different terminal connections\u003c\/li\u003e\n\u003cli\u003eInput type = Differential input\u003c\/li\u003e\n\u003cli\u003eConversion time = 300 μs for all inputs\u003c\/li\u003e\n\u003cli\u003eInput protection = Protection against wiring with supply voltage\u003c\/li\u003e\n\u003cli\u003eOutput of digital value during overload = Configurable\u003c\/li\u003e\n\u003cli\u003eConversion procedure = SAR\u003c\/li\u003e\n\u003cli\u003eInput filter = Third-order low-pass filter \/ Cutoff frequency 1 kHz\u003c\/li\u003e\n\u003cli\u003eCommon-mode range = ±12 V\u003c\/li\u003e\n\u003cli\u003eCrosstalk between channels = \u0026lt;-70 dB\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160986931453,"sku":"X20AI2622","price":531.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20AI2622.jpg?v=1785730967","url":"https:\/\/shly-plc.com\/products\/x20ai2622","provider":"Lianyou PLC","version":"1.0","type":"link"}