{"product_id":"wago-753-513-2-channel-relay-output","title":"WAGO 753-513 2-channel relay output","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eWAGO · 2-channel relay output\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e753-513\u003c\/b\u003e is a WAGO 2-channel relay output. Enclosure rating: IP20; Operating temperature: 0 … +55 °C; Mounting: DIN-35 rail; Conformity marking: CE. It is used in control panels, machine builds and spare-part replacements where the installed unit is matched to the original catalog number and a documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003cstrong\u003e0 … +55 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting\u003c\/span\u003e\u003cstrong\u003eDIN-35 rail\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eConformity marking\u003c\/span\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage (system)\u003c\/span\u003e\u003cstrong\u003e5 VDC; via data contacts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eTechnical data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage (system)\u003c\/th\u003e\n\u003ctd\u003e5 VDC; via data contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage (field)\u003c\/th\u003e\n\u003ctd\u003eTransmission of ground potential via power jumper contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption (system supply)\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent carrying capacity (power jumper contacts)\u003c\/th\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e1500 V (system\/field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching voltage (max.)\u003c\/th\u003e\n\u003ctd\u003e250 VAC, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching current (max.)\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching voltage (min.)\u003c\/th\u003e\n\u003ctd\u003e5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching current (min.)\u003c\/th\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching power\u003c\/th\u003e\n\u003ctd\u003e500 VA \/ 60 W; cos ϕ max. = 0.4; L\/R max. = 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Channels\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal type\u003c\/th\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput characteristic\u003c\/th\u003e\n\u003ctd\u003epotential-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of incoming power jumper contacts\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of outgoing power jumper contacts\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironmental requirements\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree\u003c\/th\u003e\n\u003ctd\u003e2 per IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eConnection Data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection technology: inputs \/ outputs\u003c\/th\u003e\n\u003ctd\u003e6 x CAGE CLAMP ® (outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection type\u003c\/th\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN-35 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the WAGO official technical data published for catalog number 753-513; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eWAGO 2-channel relay output variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eEnclosure rating\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eOperating temperature\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eMounting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/wago-750-513-relay-output-module\"\u003e750-513\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003ctd\u003e0 … +55 °C\u003c\/td\u003e\n\u003ctd\u003eDIN-35 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e753-513\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003ctd\u003e0 … +55 °C\u003c\/td\u003e\n\u003ctd\u003eDIN-35 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 753-513 is the device-level element in a WAGO 2-channel relay output installation. It receives the field signals and control supply listed above and switches or conditions the load within the ratings shown in the Specifications table. Wiring and protective devices are sized against enclosure rating IP20, operating temperature 0 … +55 °C, mounting DIN-35 rail — not against a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in control panels, machine builds and spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides the mounting support listed above. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for WAGO 753-513\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWAGO 753-513\u003c\/strong\u003e — WAGO industrial component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the WAGO official specification for catalog number 753-513; always cross-check the catalog number and hardware revision on the nameplate before placing an order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP20\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0 … +55 °C\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cstrong\u003eDIN-35 rail\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eConformity marking: \u003cstrong\u003eCE\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eSupply voltage (system): \u003cstrong\u003e5 VDC; via data contacts\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCross-check the ratings above with the installed device before confirming the order.\u003c\/p\u003e\n\u003ch3\u003eCommon questions about 753-513\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the supply voltage (system) data for 753-513?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for WAGO 753-513 as 5 VDC; via data contacts. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor 753-513, what does the specification table state about supply voltage (field)?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists Supply voltage (field) = Transmission of ground potential via power jumper contact for WAGO 753-513. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under current consumption (system supply) for catalog number 753-513?\u003c\/p\u003e\n\u003cp\u003eFor 753-513, current consumption (system supply) is given as 100 mA. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for 753-513?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number 753-513, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for WAGO 753-513.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 753-513 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 753-513 and the specification values listed above against the installed unit, then confirm the hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"WAGO","offers":[{"title":"New","offer_id":71341079888125,"sku":"753-513","price":47.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/unnamed_ee2356b6-61db-4060-8715-7a6a245064e1.jpg?v=1789961267","url":"https:\/\/shly-plc.com\/products\/wago-753-513-2-channel-relay-output","provider":"SHLY-PLC","version":"1.0","type":"link"}