{"product_id":"wago-750-8212-controller-pfc200","title":"WAGO 750-8212 Controller PFC200","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eWAGO · Controller PFC200\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e750-8212\u003c\/b\u003e is a WAGO Controller PFC200. Enclosure rating: IP20; Operating temperature: 0 … +55 °C; Mounting: DIN-35 rail; Conformity marking: CE. It is used in control panels, machine builds and spare-part replacements where the installed unit is matched to the original catalog number and a documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003cstrong\u003e0 … +55 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting\u003c\/span\u003e\u003cstrong\u003eDIN-35 rail\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eConformity marking\u003c\/span\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage (system)\u003c\/span\u003e\u003cstrong\u003e24 VDC, SELV\/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eTechnical data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage (system)\u003c\/th\u003e\n\u003ctd\u003e24 VDC, SELV\/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage (field)\u003c\/th\u003e\n\u003ctd\u003e24 VDC, SELV\/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP ® connection; distribution via spring contact); External fuse required: 10 A slow-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTotal current (system supply)\u003c\/th\u003e\n\u003ctd\u003e1,700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent carrying capacity (power jumper contacts)\u003c\/th\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e500 V system\/field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of outgoing power jumper contacts\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunications\u003c\/th\u003e\n\u003ctd\u003eModbus TCP master\/client; Modbus (UDP); Modbus (RTU); ETHERNET; EtherNet\/IP Adapter; EtherNet\/IP Scanner; EtherCAT Master; OPC UA Server\/Client; OPC UA Pub\/Sub; MQTT; RS-232 serial interface; RS-485 interface; BACnet\/IP; Telecontrol protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eETHERNET protocols\u003c\/th\u003e\n\u003ctd\u003eDHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransmission rate\u003c\/th\u003e\n\u003ctd\u003eETHERNET: 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransmission medium (communication\/fieldbus)\u003c\/th\u003e\n\u003ctd\u003eETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTelecontrol protocols\u003c\/th\u003e\n\u003ctd\u003eIEC 60870 (additional license as client or master); IEC 61850 (additional license as client or server); DNP3 (additional license as client or master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eCortex A8; 1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003eCODESYS V2: 16 MB; CODESYS V3: 32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData memory\u003c\/th\u003e\n\u003ctd\u003eCODESYS V2: 64 MB; CODESYS V3: 128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironmental requirements\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree\u003c\/th\u003e\n\u003ctd\u003e2 per IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eConnection Data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection technology: system supply\u003c\/th\u003e\n\u003ctd\u003e2 x CAGE CLAMP ®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection technology: field supply\u003c\/th\u003e\n\u003ctd\u003e6 x CAGE CLAMP ®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection technology: communication\/fieldbus\u003c\/th\u003e\n\u003ctd\u003eModbus (TCP, UDP): 2 x RJ-45; Modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-485 interface: 1 x D-sub 9 socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection technology: device configuration\u003c\/th\u003e\n\u003ctd\u003e1 x Male connector; 4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection type\u003c\/th\u003e\n\u003ctd\u003eSystem\/field supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the WAGO official technical data published for catalog number 750-8212; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 750-8212 is the device-level element in a WAGO Controller PFC200 installation. It receives the field signals and control supply listed above and switches or conditions the load within the ratings shown in the Specifications table. Wiring and protective devices are sized against enclosure rating IP20, operating temperature 0 … +55 °C, mounting DIN-35 rail — not against a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in control panels, machine builds and spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides the mounting support listed above. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for WAGO 750-8212\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWAGO 750-8212\u003c\/strong\u003e — WAGO industrial component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the WAGO official specification for catalog number 750-8212; always cross-check the catalog number and hardware revision on the nameplate before placing an order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP20\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0 … +55 °C\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cstrong\u003eDIN-35 rail\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eConformity marking: \u003cstrong\u003eCE\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eSupply voltage (system): \u003cstrong\u003e24 VDC, SELV\/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCross-check the ratings above with the installed device before confirming the order.\u003c\/p\u003e\n\u003ch3\u003eCommon questions about 750-8212\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the supply voltage (system) data for 750-8212?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for WAGO 750-8212 as 24 VDC, SELV\/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor 750-8212, what does the specification table state about supply voltage (field)?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists Supply voltage (field) = 24 VDC, SELV\/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP ® connection; distribution via spring contact); External fuse required: 10 A slow-blow for WAGO 750-8212. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under total current (system supply) for catalog number 750-8212?\u003c\/p\u003e\n\u003cp\u003eFor 750-8212, total current (system supply) is given as 1,700 mA. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for 750-8212?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number 750-8212, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for WAGO 750-8212.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 750-8212 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 750-8212 and the specification values listed above against the installed unit, then confirm the hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"WAGO","offers":[{"title":"New","offer_id":71337215394045,"sku":"750-8212","price":812.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1024-0200002700033201000100b6-DE.jpg?v=1789970748","url":"https:\/\/shly-plc.com\/products\/wago-750-8212-controller-pfc200","provider":"SHLY-PLC","version":"1.0","type":"link"}