{"product_id":"siemens-6es7711-2ba11-2fb3-field-pg-programming-device","title":"Siemens 6ES7711-2BA11-2FB3 SIMATIC Field PG Programming Device","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eSiemens · SIMATIC Field PG\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e6ES7711-2BA11-2FB3\u003c\/b\u003e is a Siemens SIMATIC Field PG portable programming device built on the Pentium 4 platform. It combines a rugged notebook form factor with the display, drives and interfaces required to program, commission and service SIMATIC S5 \/ S7 automation systems. The exact processor speed, memory, drives and preinstalled engineering software depend on the catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eDevice type\u003c\/span\u003e\u003cstrong\u003ePortable programming device (Field PG)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003e14.1\" TFT XGA (1024 × 768)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ePower supply\u003c\/span\u003e\u003cstrong\u003eExternal 100–240 VAC, 50\/60 Hz + Li-Ion battery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDimensions \/ weight\u003c\/span\u003e\u003cstrong\u003e328 × 294 × 52 mm · approx. 4 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice type\u003c\/th\u003e\n\u003ctd\u003eSIMATIC Field PG portable programming device, Pentium 4 platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating system\u003c\/th\u003e\n\u003ctd\u003eWindows 2000 \/ XP Professional (configuration varies by catalog number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering software\u003c\/th\u003e\n\u003ctd\u003eSIEMENS STEP engineering software (STEP 7 \/ STEP 5 \/ STEP 7 Micro\/WIN depending on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eDisplay\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePanel\u003c\/th\u003e\n\u003ctd\u003e14.1\" TFT, resolution 1024 × 768 (XGA), up to 256k colors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMass storage and drives\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptical drive\u003c\/th\u003e\n\u003ctd\u003eInternal CD-ROM \/ DVD-ROM \/ DVD-ROM\/CD-RW (depends on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFloppy drive\u003c\/th\u003e\n\u003ctd\u003e3.5\" floppy or SuperDisk (LS-120\/LS-240) depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eInterfaces\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003eOnboard Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSerial \/ parallel\u003c\/th\u003e\n\u003ctd\u003eCOM1 (RS-232) and parallel port (LPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB \/ expansion\u003c\/th\u003e\n\u003ctd\u003eUSB ports; PC-Card slot (CardBus, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming interface\u003c\/th\u003e\n\u003ctd\u003eMPI\/DP interface support (status LED and interface cards via PC-Card slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003ePower\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine voltage\u003c\/th\u003e\n\u003ctd\u003eExternal power supply 100 VAC to 240 VAC (+10 % \/ −15 %), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power consumption\u003c\/th\u003e\n\u003ctd\u003e90 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eLithium-Ion rechargeable battery pack (9 cells), charge-status monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical and environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (w × h × d)\u003c\/th\u003e\n\u003ctd\u003e328 × 294 × 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP30 (covers closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eCompliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN 55022 class B, EN 61000-4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eProtection class I per IEC 60950 \/ EN 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Siemens SIMATIC Field PG equipment manual (A5E00075760-04) for this device family; configuration details not confirmed for this catalog number are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eSiemens Field PG variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eProduct family\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e6ES7711-2BA11-2FB3\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003eSIMATIC Field PG (Pentium 4 platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/siemens-6es7711-2ba25-3fb4-field-pg-programming-device\"\u003e6ES7711-2BA25-3FB4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC Field PG (Pentium 4 platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/siemens-6es7711-2ba31-2lg3-field-pg-programming-device\"\u003e6ES7711-2BA31-2LG3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC Field PG (Pentium 4 platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/siemens-6es7711-2ca22-2lb2-field-pg-programming-device\"\u003e6ES7711-2CA22-2LB2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC Field PG (Pentium 4 platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eAll variants share the same Field PG chassis and interface layout; processor speed, memory, drives, display option, keyboard layout and preinstalled engineering software differ by catalog number. Selecting a different catalog number changes the delivered configuration, not the device family.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the workflow\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7711-2BA11-2FB3 is the field engineering and service terminal for SIMATIC S5 \/ S7 automation systems. It is used to write and transfer PLC programs over the MPI\/DP programming interface or onboard Ethernet, to commission and diagnose controllers on site, and to run the SIEMENS STEP engineering tools carried on its internal drives.\u003c\/p\u003e\n\u003cp\u003eTypical deployments are commissioning, maintenance and breakdown service of SIMATIC S5 \/ S7 installations, where the unit travels with the service engineer. Record the full catalog number and revision from the nameplate of the unit being replaced before ordering a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eBefore you specify\u003c\/h3\u003e\n\u003cul class=\"shly-list\"\u003e\n\u003cli\u003e\n\u003cb\u003eConfiguration.\u003c\/b\u003e Match processor speed, memory, drive configuration and preinstalled STEP software to the unit being replaced; these differ between catalog numbers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInterfaces.\u003c\/b\u003e Confirm the programming interfaces you need (Ethernet, MPI\/DP, COM1) are provided by the variant you order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMarking.\u003c\/b\u003e Record the catalog number and revision from the nameplate of the installed unit for a like-for-like spare.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat kind of device is this?\u003c\/p\u003e\n\u003cp\u003eIt is a SIMATIC Field PG portable programming device — a rugged notebook-class engineering terminal for SIMATIC S5 \/ S7 PLC systems, not a PLC module itself.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat display does it have?\u003c\/p\u003e\n\u003cp\u003eA 14.1\" TFT panel with XGA resolution of 1024 × 768 pixels and up to 256k colors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow is the device powered?\u003c\/p\u003e\n\u003cp\u003eIt runs from the external 100–240 VAC power supply or from its internal Lithium-Ion battery pack; the battery status is shown by the system LEDs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat replaces a unit that is no longer in production?\u003c\/p\u003e\n\u003cp\u003eRecord the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function, interfaces and the installed engineering software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":46179959341309,"sku":"6ES7711-2BA11-2FB3","price":278.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/5bc90234244e38b9f0ec2a9ec80bee30_944b503c-9682-43c7-b20f-f63b83544458.png?v=1793621782","url":"https:\/\/shly-plc.com\/products\/siemens-6es7711-2ba11-2fb3-field-pg-programming-device","provider":"SHLY-PLC","version":"1.0","type":"link"}