{"product_id":"rj71gf11t2","title":"Mitsubishi RJ71GF11-T2 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi RJ71GF11-T2\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series RJ71GF11-T2\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1814 connections For the system with the SIL2 Process CPU: 120 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per the same communication destination station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 connection For the system with the SIL2 Process CPU: 32 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of link points per safety connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003einput: 8 words output: 8 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransient transmission capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1920 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet cable which satisfies 1000BASE-T standard: Category 5e or higher, straight cable (double shielded, STP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum station-to-station distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m (conforms to ANSI\/TIA\/EIA-568-B (Category 5e))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOverall cable distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology: 12000 m (when 121 stations are connected) Star topology: Depends on the system configuration Ring topology: 12100 m (when 121 stations are connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of cascade connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 levels maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of connectable stations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121 stations (manager station: 1, device station: 120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToken passing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm (base unit mounting side: 98 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178751229,"sku":"RJ71GF11-T2","price":167.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMjcvY2UyY2FlZGMtZGRjYS00OGZiLWIwZDUtYmNjMDczNTAyNjZkL3JqNzFnZjExLXQyLmpwZyJdLFsicCIsInRodW1iIiwiNDAweDQwMFx1MDAzZSJdXQ_2d36250f-66ea-4a5a-88ac-31434798.jpg?v=1742537153","url":"https:\/\/shly-plc.com\/products\/rj71gf11t2","provider":"Lianyou PLC","version":"1.0","type":"link"}