{"product_id":"qj71c24nr4","title":"Mitsubishi QJ71C24NR4 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QJ71C24N-R4\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QJ71C24N-R4\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInterface - CH1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-422\/485-compliance (2-piece plug-in connector socket block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInterface - CH2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-422\/485-compliance (2-piece plug-in connector socket block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method - Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex\/half-duplex communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method - MC protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf-duplex communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method - Predefined protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex\/half-duplex communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method - Nonprocedural protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex\/half-duplex communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method - Bidirectional protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex\/half-duplex communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSynchronization method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStart-stop synchronization method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400 bps • Transmission speed 230400 bps is available for only CH1. (Not available for CH2) • Total transmission speed of two interfaces is available up to 230400 bps. • Total transmission speed of two interfaces is a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission distance - RS-422\/485\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1200 m (overall distance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eData format - Start bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eData format - Data bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eData format - Parity bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (vertical parity) or none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eData format - Stop bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccess cycle - MC protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcesses one request during the END processing of the CPU module of the station. Number of scans that must be processed\/number of link scans depends on the contents of the request.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccess cycle - Predefined protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSends or receives data when requested with the dedicated instruction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccess cycle - Nonprocedural protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSends each time a send request is issued. Can receive at any time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccess cycle - Bidirectional protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSends each time a send request is issued. Can receive at any time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eError detection - Parity check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelected for all protocols and when this check is enabled, ODD or EVEN is selected by a parameter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eError detection - Sum check code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor the MC or bidirectional protocol, selected by a parameter. For the predefined protocol, whether or not a sum check code is needed depends on the selected protocol. For the nonprocedural protocol, selected in the user frame.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission control - RS-422\/485 - DTR\/DSR control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission control - RS-422\/485 - RS\/CS control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission control - RS-422\/485 - CD (DCD) signal control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission control - RS-422\/485 - DC1\/DC3 (Xon\/Xoff) control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission control - RS-422\/485 - DC2\/DC4 control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLine configuration for connection (Target device side : CPU module side) - RS-422\/485\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1，1:n，n:1，m:n (The total number of 'n' or 'm+n' is up to 32.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLine configuration for data communication (Target device side : CPU module side) - RS-422\/485 - MC protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1，1:n，m:n (The total number of 'n' or 'm+n' is up to 32.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLine configuration for data communication (Target device side : CPU module side) - RS-422\/485 - Predefined protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1，n:1 (The total number of 'n' is up to 32.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLine configuration for data communication (Target device side : CPU module side) - RS-422\/485 - Nonprocedural protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1, 1:n, n:1 (The total number of 'n' is up to 32.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLine configuration for data communication (Target device side : CPU module side) - RS-422\/485 - Bidirectional protocol communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137215680765,"sku":"QJ71C24NR4","price":95.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/DrZGqeunqIoAAuHQKoxNp3W0vbQLjHAeIC6xFzlYPHYU4GPmyybZyuvYhwue.jpg?v=1742538043","url":"https:\/\/shly-plc.com\/products\/qj71c24nr4","provider":"Lianyou PLC","version":"1.0","type":"link"}