{"product_id":"prosoft-technology-mvi69-adm-application-development-communication","title":"ProSoft Technology MVI69-ADM Communication Module","description":"\u003cdiv style=\"max-width:100%;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;font-size:15px;line-height:1.6;overflow-wrap:anywhere;\"\u003e\n\u003ch2 style=\"font-size:22px;line-height:1.3;margin:0 0 12px;color:#1a1a1a;\" class=\"desc-model-title\"\u003eMVI69-ADM ProSoft C Programmable Application Development Module for 1769 CompactLogix\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003eProSoft Technology MVI69-ADM\u003c\/strong\u003e is a single-slot programmable application development module for Rockwell CompactLogix PAC and MicroLogix 1500 LRP controllers. It supports ANSI C custom programming for proprietary protocol conversion, serial data parsing and custom gateway functions, without built-in Ethernet port. Technical data sourced directly from official ProSoft MVI69-ADM datasheet \u0026amp; developer guide. Supplied by SHLY-PLC, an independent industrial automation distributor.  Contact our team for compatibility verification.\u003c\/p\u003e\n\u003cp\u003eManufacturer status: discontinued.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eOrder Code:\u003c\/strong\u003e MVI69-ADM\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e MVI69 Series for 1769 CompactLogix\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e ANSI C programmable application development module, serial-only custom protocol gateway\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eBackplane:\u003c\/strong\u003e Single slot 1769 CompactLogix \/ MicroLogix 1500 LRP chassis mounting (Excludes 1769-L23E-QBFC1B, 1769-L16x, 1769-L18x)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eEthernet Interface:\u003c\/strong\u003e No onboard Ethernet port\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 2 configurable serial ports, RS232\/422\/485, fully controlled by user ANSI C application code\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e ANSI C development environment, user compiles custom firmware for serial protocol conversion and custom device interfaces\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eData Exchange:\u003c\/strong\u003e Large user-defined module database for high-volume backplane data transfer with CompactLogix controller\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Development Toolkit, Add-On Instruction (AOI) \u0026amp; sample ladder logic included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eLED Status:\u003c\/strong\u003e Power, Module Status (OK), Application (APP), Serial Port \u0026amp; fault LEDs\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e cULus UL508 \/ UL1604, Class I Div 2 Groups A,B,C,D T6; ATEX II 3G Ex nA IIC T6 X, CE RoHS compliant\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eLifecycle:\u003c\/strong\u003e Discontinued OEM production, aftermarket spare part only\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eTypical Use:\u003c\/strong\u003e Serial proprietary protocol gateway, legacy serial equipment retrofit, custom ASCII data acquisition \u0026amp; transformation for factory automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp style=\"font-size:13px;color:#666666;margin:0 0 4px;\"\u003eOfficial Datasheet \u0026amp; Developer Guide Technical Parameters\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed;margin:6px 0 18px;font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#D7282F;color:#ffffff;padding:7px 11px;text-align:left;vertical-align:top;word-break:break-word;font-weight:700;\"\u003eTechnical Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eMVI69-ADM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eHardware Type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e1769 Single-Slot Programmable C Application Module (Serial Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e800mA @ 5.1 VDC, 3mA @24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eNot equipped, no onboard RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eSerial Ports\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e2 ports, jumper selectable RS232\/RS422\/RS485, fully controlled by custom C code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eProgramming Language\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eANSI C, compiled user application firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eEnvironmental Ratings\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e0°C ~ +60°C (32°F ~ +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e-40°C ~ +85°C (-40°F ~ +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e5% ~ 95% RH, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eAgency Certifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ecULus\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eUL508, UL1604, Class I Div 2 Groups A,B,C,D T6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eATEX\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eII 3 G Ex nA IIC T6 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eCompatibility \u0026amp; Cross-References\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003eMVI69-ADM\u003c\/strong\u003e is legacy programmable application module for Rockwell 1769 CompactLogix \/ MicroLogix 1500 LRP rack. It appears as standard 1769 I\/O module to PLC processor, AOI instructions handle data mapping between custom module application and CompactLogix controller tags. Not compatible with 1769-L23E-QBFC1B, 1769-L16x, 1769-L18x processors. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for product identification only.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eCustom serial protocol gateway and conversion for non-standard \/ proprietary serial industrial devices\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eLegacy serial machine integration, custom ASCII data parsing, serial data acquisition\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eSerial device alarm handling and custom serial data transformation\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eRetrofit and spare replacement of serial-only custom programmed CompactLogix interface modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eWarranty\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e MVI69-ADM discontinued OEM production, supply as aftermarket spare; contact us for real-time stock status.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e orders are processed within 2-4 business days after payment confirmation; standard worldwide delivery is about 5-8 business days, express shipping available, orders over $500 ship free.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003cdiv style=\"font-size:13px;line-height:1.5;color:#555555;background:#f7f7f8;border-left:3px solid #D7282F;padding:9px 12px 0 12px;margin:12px 0;\"\u003eIndependent supplier: ProSoft Technology part MVI69-ADM is supplied by SHLY-PLC, an independent industrial automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/div\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What is MVI69-ADM?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: MVI69-ADM is ProSoft programmable ANSI C application development module (serial only) for 1769 CompactLogix \/ MicroLogix1500 LRP, designed for custom serial protocol gateways.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What interfaces does MVI69-ADM include?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: Two configurable RS232\/422\/485 serial ports, no built-in Ethernet port.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What is the difference between MVI69-ADM and MVI69-ADMNET?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: MVI69-ADM is serial-only with dual serial ports, no Ethernet. MVI69-ADMNET is the upgraded variant with onboard 10\/100 Ethernet RJ45 port.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: Which CPUs are incompatible?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: 1769-L23E-QBFC1B, 1769-L16x and 1769-L18x controllers cannot be used with MVI69-ADM.\u003c\/p\u003e\n\u003cp style=\"font-size:12px;color:#888888;text-align:center;margin:18px 0 4px;\"\u003eMVI69-ADM · Technical reference data · Independently supplied by SHLY-PLC\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"ProSoft Technology","offers":[{"title":"New","offer_id":46160830365949,"sku":"MVI69-ADM","price":1250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MVI69-ADM.jpg?v=1791872691","url":"https:\/\/shly-plc.com\/products\/prosoft-technology-mvi69-adm-application-development-communication","provider":"SHLY-PLC","version":"1.0","type":"link"}