{"product_id":"prosoft-technology-5205-dfnt-pdps-gateway","title":"ProSoft Technology 5205-DFNT-PDPS Gateway","description":"\u003cdiv style=\"max-width:100%;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;font-size:15px;line-height:1.6;overflow-wrap:anywhere;\"\u003e\n\u003ch2 style=\"font-size:22px;line-height:1.3;margin:0 0 12px;color:#1a1a1a;\" class=\"desc-model-title\"\u003e5205-DFNT-PDPS ProLinx EtherNet\/IP to PROFIBUS DP Slave Gateway | ProSoft Technology\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003eProSoft Technology 5205-DFNT-PDPS\u003c\/strong\u003e is a ProLinx DIN rail mounted protocol gateway bridging EtherNet\/IP and PROFIBUS DP networks. It operates as PROFIBUS DP V0 Slave for connection to PROFIBUS DP Master controllers, enabling bidirectional data mapping between EtherNet\/IP PACs and Siemens PROFIBUS master systems. Configured via ProSoft Configuration Builder (PCB) software, it includes GSD file for PROFIBUS integration, ideal for factory retrofit and cross-network data exchange. Technical data sourced from ProSoft 5205-DFNT-PDPS datasheet \u0026amp; user manual. Supplied by SHLY-PLC, an independent industrial automation distributor; each unit undergoes visual inspection and functional testing before shipment for legacy PROFIBUS and EtherNet\/IP integration and spare replacement projects. Contact our team for compatibility verification.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eOrder Code:\u003c\/strong\u003e 5205-DFNT-PDPS\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eModel:\u003c\/strong\u003e EtherNet\/IP to PROFIBUS DP Slave Gateway\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eFunction:\u003c\/strong\u003e PROFIBUS DP V0 Slave, bi-directional data exchange between EtherNet\/IP controllers and PROFIBUS DP Master\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003ePROFIBUS DP Interface:\u003c\/strong\u003e DB9 female connector, PDPS slave, supplied with GSD file\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eEthernet:\u003c\/strong\u003e 10\/100 Base-T RJ45, EtherNet\/IP adapter, supports implicit Class 1 cyclic I\/O messaging\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eEtherNet\/IP:\u003c\/strong\u003e Supports multiple EtherNet\/IP controller connections, configurable data mapping\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB) software, offline config download\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Power, Ethernet, PROFIBUS, Fault status LEDs\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN rail metal enclosure\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eLifecycle:\u003c\/strong\u003e Discontinued OEM production, available as aftermarket spare parts\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eApplication:\u003c\/strong\u003e Siemens PROFIBUS DP system upgrade, connect PROFIBUS DP master to Allen‑Bradley ControlLogix \/ CompactLogix PAC over EtherNet\/IP, plant modernization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp style=\"font-size:13px;color:#666666;margin:0 0 4px;\"\u003eTechnical parameters compiled from ProSoft official 5205-DFNT-PDPS datasheet and user manual.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed;margin:6px 0 18px;font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#D7282F;color:#ffffff;padding:7px 11px;text-align:left;vertical-align:top;word-break:break-word;font-weight:700;\"\u003eTechnical Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e5205-DFNT-PDPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eEtherNet\/IP to PROFIBUS DP Slave Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePorts\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e1×10\/100 RJ45 Ethernet;1×DB9-F PROFIBUS DP port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e10 ~ 32 VDC, nominal 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePROFIBUS Protocol\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePROFIBUS DP V0 Slave (PDPS), GSD file included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eEnvironmental Ratings\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e0 °C ~ +55 °C (32°F ~131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;word-break:break-word;\"\u003e-40 °C ~ +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;word-break:break-word;\"\u003e5% ~95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eCompatibility \u0026amp; Cross-References\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003e5205-DFNT-PDPS\u003c\/strong\u003e belongs to ProSoft ProLinx 5200 series gateway family. Compatible with Siemens S7 PROFIBUS DP Master PLC systems and Allen‑Bradley EtherNet\/IP PAC including ControlLogix and CompactLogix. It enables seamless cyclic data mapping between PROFIBUS DP master network and EtherNet\/IP controllers. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for product identification only.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eLegacy Siemens PROFIBUS DP system integration and retrofit\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eConnect PROFIBUS DP master PLC to Allen‑Bradley EtherNet\/IP PAC over Ethernet\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eCross protocol cyclic data mapping between PROFIBUS DP and EtherNet\/IP networks\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eFactory phased upgrade without replacing existing PROFIBUS DP field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eWarranty\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eAvailability:\u003c\/strong\u003e 5205-DFNT-PDPS discontinued OEM production, supply as aftermarket spare; contact us for real-time stock status.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eInspection \u0026amp; testing:\u003c\/strong\u003e each unit is visually inspected and functionally checked before packing.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e \u003cstrong\u003eDelivery:\u003c\/strong\u003e orders are processed within 2-4 business days after payment confirmation; standard worldwide delivery is about 5-8 business days, express shipping available, orders over $500 ship free.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003cdiv style=\"font-size:13px;line-height:1.5;color:#555555;background:#f7f7f8;border-left:3px solid #D7282F;padding:9px 12px;margin:12px 0;\"\u003eIndependent supplier: ProSoft Technology part 5205-DFNT-PDPS is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/div\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D7282F;color:#1a1a1a;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What is 5205-DFNT-PDPS?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: 5205-DFNT-PDPS is ProSoft ProLinx DIN rail protocol gateway for EtherNet\/IP to PROFIBUS DP Slave conversion, acts as DP V0 slave for Siemens PROFIBUS master controllers.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What software configures this gateway?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: ProSoft Configuration Builder (PCB) software for offline configuration download, GSD file included for PROFIBUS master project import.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What power supply is required?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: 10~32 VDC input, nominal 24VDC, maximum power consumption 5W.\u003c\/p\u003e\n\u003cp style=\"font-size:12px;color:#888888;text-align:center;margin:18px 0 4px;\"\u003e5205-DFNT-PDPS · Technical reference data · Independently supplied by SHLY-PLC\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"ProSoft Technology","offers":[{"title":"Default Title","offer_id":71124746600701,"sku":"5205-DFNT-PDPS","price":398.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/5205-DFNT-PDPS.jpg?v=1791853689","url":"https:\/\/shly-plc.com\/products\/prosoft-technology-5205-dfnt-pdps-gateway","provider":"SHLY-PLC","version":"1.0","type":"link"}