{"product_id":"proface-pfxsp5600tpdrb4ty2-sp5000-hmi-operator-terminal","title":"Pro-face PFXSP5600TPDRB4TY2 HMI Panel","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePro-face · SP5000 smart portal HMI\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003ePFXSP5600TPDRB4TY2\u003c\/b\u003e is a Pro-face HMI panel with Screen size 12.1 inch; Resolution 1024 x 768 XGA; Supply voltage 24 V DC (IEC 60950-1). It is used in machine operator panels, control cabinets, local HMI stations where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eScreen size\u003c\/span\u003e\u003cstrong\u003e12.1 inch\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eResolution\u003c\/span\u003e\u003cstrong\u003e1024 x 768 XGA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 60950-1)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCutout dimensions\u003c\/span\u003e\u003cstrong\u003e301.5 x 227.5 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e44.5 W \/ 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e1024 x 768 XGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScreen size\u003c\/th\u003e\n\u003ctd\u003e12.1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd\u003e315 x 241 x 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mount (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP65 (IEC 60529) front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCutout dimensions\u003c\/th\u003e\n\u003ctd\u003e301.5 x 227.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight life\u003c\/th\u003e\n\u003ctd\u003e50000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTouch type\u003c\/th\u003e\n\u003ctd\u003eResistive film (analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+50 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Pro-face SP5000 smart portal HMI specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003ePro-face SP5000 smart portal HMI variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eCutout dimensions\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eScreen size\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eSupply voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003ePFXSP5600TPDRB4TY2\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e301.5 x 227.5 mm\u003c\/td\u003e\n\u003ctd\u003e12.1 inch\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-pfxsp5600tad-sp5000-hmi-operator-terminal\"\u003ePFXSP5600TAD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e301.5 x 227.5 mm\u003c\/td\u003e\n\u003ctd\u003e12.1 inch\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-pfxsp5660tpd-sp5000-hmi-operator-terminal\"\u003ePFXSP5660TPD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e301.5 x 227.5 mm\u003c\/td\u003e\n\u003ctd\u003e12.1 inch\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-pfxsp5690wad-sp5000-hmi-operator-terminal\"\u003ePFXSP5690WAD\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e295 x 217 mm\u003c\/td\u003e\n\u003ctd\u003e12.1 inch wide, outdoor\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe PFXSP5600TPDRB4TY2 is the device-level element in a Pro-face HMI panel installation. It receives the field signals and control supply listed above — 24 V DC (IEC 60950-1) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in machine operator panels, control cabinets, local HMI stations, where the unit is matched to the original catalog number and the enclosure provides Panel mount (IEC 60529) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Industrial PFXSP5600TPDRB4TY2\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PFXSP5600TPDRB4TY2\u003c\/strong\u003e — Operator panel for visualisation, parameter setting and alarm handling on a control cabinet door or console. The figures below are taken from the specification table on this page for catalog number PFXSP5600TPDRB4TY2; verify the catalog number against your bill of materials before requesting a quotation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBacklight life: \u003cstrong\u003e50000 hours\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eScreen size: \u003cstrong\u003e12.1 inch\u003c\/strong\u003e — Check this value against the nameplate of the installed unit before ordering.\u003c\/li\u003e\n\u003cli\u003eCertifications: \u003cstrong\u003eCE, UL, cULus\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP65 (IEC 60529) front\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a discontinued unit, match function and electrical ratings rather than the label alone.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about PFXSP5600TPDRB4TY2\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the operating temperature data for PFXSP5600TPDRB4TY2?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Industrial PFXSP5600TPDRB4TY2 as 0...+50 °C (IEC 60068-2-1). Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor PFXSP5600TPDRB4TY2, what does the specification table state about weight?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists weight = 3.2 kg for Industrial PFXSP5600TPDRB4TY2. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under resolution for catalog number PFXSP5600TPDRB4TY2?\u003c\/p\u003e\n\u003cp\u003eFor PFXSP5600TPDRB4TY2, resolution is given as 1024 x 768 XGA. Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the PFXSP5600TPDRB4TY2 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number PFXSP5600TPDRB4TY2 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of PFXSP5600TPDRB4TY2 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number PFXSP5600TPDRB4TY2 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pro-face","offers":[{"title":"Default Title","offer_id":71124892221693,"sku":"PFXSP5600TPDRB4TY2","price":2188.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/5fe1c36e31dca1da46423a31f9365c41_b5965055-2350-4752-b667-3da0ec3f508d.png?v=1789047775","url":"https:\/\/shly-plc.com\/products\/proface-pfxsp5600tpdrb4ty2-sp5000-hmi-operator-terminal","provider":"SHLY-PLC","version":"1.0","type":"link"}