{"product_id":"proface-gp4104w1d-gp-series-hmi-operator-terminal","title":"Pro-face GP4104W1D HMI Panel","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePro-face · HMI Panel\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eGP4104W1D\u003c\/b\u003e is a Pro-face HMI panel with Screen size 3.4 inch; Resolution 200 x 80 pixels; Supply voltage 24 V DC (IEC 60950-1). It is used in machine operator panels, control cabinets, local HMI stations where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eScreen size\u003c\/span\u003e\u003cstrong\u003e3.4 inch\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eResolution\u003c\/span\u003e\u003cstrong\u003e200 x 80 pixels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 60950-1)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCutout dimensions\u003c\/span\u003e\u003cstrong\u003e105 x 66 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e~3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e200 x 80 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScreen size\u003c\/th\u003e\n\u003ctd\u003e3.4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003ctd\u003ecompact GP4100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e~0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mount (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP65 (IEC 60529) front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCutout dimensions\u003c\/th\u003e\n\u003ctd\u003e105 x 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTouch type\u003c\/th\u003e\n\u003ctd\u003eResistive film (analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+50 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Pro-face HMI Panel specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003ePro-face HMI Panel variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eCutout dimensions\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eScreen size\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eSupply voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eGP4104W1D\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e105 x 66 mm\u003c\/td\u003e\n\u003ctd\u003e3.4 inch\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-gp4104g1d-gp-series-hmi-operator-terminal\"\u003eGP4104G1D\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 66 mm\u003c\/td\u003e\n\u003ctd\u003e3.4 inch\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-gp4104-main-hmi-panel\"\u003eGP4104-MAIN\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/proface-gp4100-hmi-panel\"\u003eGP4100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe GP4104W1D is the device-level element in a Pro-face HMI panel installation. It receives the field signals and control supply listed above — 24 V DC (IEC 60950-1) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in machine operator panels, control cabinets, local HMI stations, where the unit is matched to the original catalog number and the enclosure provides Panel mount (IEC 60529) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Industrial GP4104W1D\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial GP4104W1D\u003c\/strong\u003e — Operator panel for visualisation, parameter setting and alarm handling on a control cabinet door or console. The figures below are taken from the specification table on this page for catalog number GP4104W1D; verify the catalog number against your bill of materials before requesting a quotation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption: \u003cstrong\u003e~3 W\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eWeight: \u003cstrong\u003e~0.2 kg\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eCutout dimensions: \u003cstrong\u003e105 x 66 mm\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0...+50 °C (IEC 60068-2-1)\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about GP4104W1D\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the power consumption data for GP4104W1D?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Industrial GP4104W1D as ~3 W. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor GP4104W1D, what does the specification table state about weight?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists weight = ~0.2 kg for Industrial GP4104W1D. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under dimensions (H x W x D) for catalog number GP4104W1D?\u003c\/p\u003e\n\u003cp\u003eFor GP4104W1D, dimensions (H x W x D) is given as compact GP4100. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the GP4104W1D replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number GP4104W1D and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for GP4104W1D?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number GP4104W1D, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial GP4104W1D.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pro-face","offers":[{"title":"Default Title","offer_id":71124901953789,"sku":"GP4104W1D","price":1833.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/5fe1c36e31dca1da46423a31f9365c41_1e39706d-e6f7-447f-aba5-08a62ce8fafd.png?v=1789047414","url":"https:\/\/shly-plc.com\/products\/proface-gp4104w1d-gp-series-hmi-operator-terminal","provider":"SHLY-PLC","version":"1.0","type":"link"}