{"product_id":"pilz-773732-safety-relay","title":"Pilz 773732 Safety Relay","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003cmeta name=\"google\" content=\"notranslate\"\u003e\n\u003ctitle\u003e773732 — 773732 - PNOZ mc3p PROFIBUS DP Module\u003c\/title\u003e\n\u003cstyle\u003e\n.desc-model-title{display:block;border:none;outline:none;text-transform:none;padding:0;background:none;margin:inherit;}\n.desc-model-title {font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}\n\n :root{\n --abb-red:#E2001A; --abb-dark:#1A1A1A; --ink:#222; --muted:#5f6368;\n --line:#e3e5e8; --bg:#f5f6f8; --card:#fff; --accent-soft:#fdecec;\n --blue:#4a6cf7; --info-bg:#eef3ff; --info-line:#4a6cf7; --info-ink:#22345e;\n }\n *{box-sizing:border-box;}\n body{margin:0;font-family:\"Segoe UI\",Arial,Helvetica,sans-serif;color:var(--ink);background:var(--bg);line-height:1.55;font-size:15px;}\n .wrap{max-width:1080px;margin:0 auto;padding:0 0 64px;}\n header.hero{background:linear-gradient(120deg,#1a1a1a,#333);color:#fff;padding:38px 0 30px;margin-bottom:24px;border-bottom:6px solid var(--abb-red);}\n header.hero .wrap{padding:0 24px;}\n .brand{display:flex;align-items:center;gap:12px;margin-bottom:18px;}\n .brand .logo{background:var(--abb-red);color:#fff;font-weight:800;letter-spacing:1px;padding:4px 10px;border-radius:3px;font-size:20px;}\n .brand .fam{font-size:14px;color:#cfcfcf;text-transform:uppercase;letter-spacing:2px;}\n h1{font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}\n .subtitle{color:#bdbdbd;font-size:15px;margin:0 0 18px;}\n .chips{display:flex;flex-wrap:wrap;gap:8px;}\n .chip{background:rgba(255,255,255,.1);border:1px solid rgba(255,255,255,.25);border-radius:20px;padding:4px 14px;font-size:13px;color:#f1f1f1;}\n .chip b{color:#fff;}\n section{background:var(--card);border:1px solid var(--line);border-radius:10px;padding:22px 26px;margin:18px 0;}\n h2{font-size:19px;margin:0 0 14px;padding-bottom:10px;border-bottom:2px solid var(--abb-red);display:inline-block;}\n h3{font-size:15px;margin:18px 0 8px;color:var(--abb-dark);}\n table{border-collapse:collapse;width:100%;margin:8px 0 6px;font-size:14px;}\n th,td{text-align:left;padding:9px 12px;border-bottom:1px solid var(--line);vertical-align:top;}\n th{background:#f0f1f3;font-weight:600;color:#333;}\n tr:last-child td,tr:last-child th{border-bottom:none;}\n td.val{font-weight:500;}\n .unit{color:var(--muted);font-weight:400;}\n .grid2{display:grid;grid-template-columns:1fr 1fr;gap:0 28px;}\n .cards{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:6px 0 4px;}\n .stat{border:1px solid var(--line);border-radius:8px;padding:14px;background:#fafbfc;}\n .stat .k{font-size:12px;color:var(--muted);text-transform:uppercase;letter-spacing:.6px;margin-bottom:6px;}\n .stat .v{font-size:20px;font-weight:700;color:var(--abb-dark);}\n .stat .v small{font-size:12px;font-weight:500;color:var(--muted);}\n .infonote{background:var(--info-bg);border-left:4px solid var(--info-line);padding:12px 16px;border-radius:0 6px 6px 0;font-size:14px;color:var(--info-ink);margin:0;}\n .infonote b{color:#16264d;}\n .rednote{background:var(--accent-soft);border-left:4px solid var(--abb-red);padding:10px 14px;border-radius:0 6px 6px 0;font-size:13.5px;margin:12px 0 0;color:#5a2020;}\n .iomap{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:8px 0 4px;}\n .iocard{border:1px solid var(--line);border-radius:8px;padding:14px;background:#fafbfc;text-align:center;}\n .iocard .num{font-size:28px;font-weight:800;color:var(--abb-red);line-height:1.1;}\n .iocard .lbl{font-size:12px;color:var(--muted);text-transform:uppercase;letter-spacing:.6px;margin-top:6px;}\n .iocard .sub{font-size:12.5px;color:#444;margin-top:4px;}\n .code-flow{display:flex;flex-wrap:wrap;gap:8px;margin:8px 0 14px;}\n .seg{border:1px solid var(--line);border-radius:8px;padding:8px 12px;background:#fafbfc;font-size:13px;}\n .seg b{display:block;font-family:Consolas,monospace;font-size:14.5px;color:var(--abb-red);}\n .seg span{color:var(--muted);font-size:12px;}\n footer{text-align:center;color:var(--muted);font-size:12px;margin-top:26px;}\n @media (max-width:820px){.grid2{grid-template-columns:1fr;}.cards{grid-template-columns:repeat(2,1fr);}.iomap{grid-template-columns:1fr 1fr;}}\n @media print{body{background:#fff;font-size:12px;}section{break-inside:avoid;border:none;border-top:1px solid #ccc;border-radius:0;}header.hero{print-color-adjust:exact;-webkit-print-color-adjust:exact;}}\n\u003c\/style\u003e\n\n\n\n\u003cheader class=\"hero\"\u003e\n \u003cdiv class=\"wrap\"\u003e\n \u003cdiv class=\"brand\"\u003e\n \u003cspan class=\"logo\"\u003ePILZ\u003c\/span\u003e\n \u003cspan class=\"fam\"\u003ePNOZmulti classic | configurable safety system | fieldbus communication module\u003c\/span\u003e\n \u003c\/div\u003e\n \u003ch2 class=\"desc-model-title\"\u003e773732 — PNOZ mc3p PROFIBUS DP Module\u003c\/h2\u003e\n \u003cp class=\"subtitle\"\u003ePROFIBUS-DP fieldbus communication expansion module for PNOZmulti classic · 24 V DC · diagnostics \u0026amp; standard process data\u003c\/p\u003e\n \u003cdiv class=\"chips\"\u003e\n \u003cspan class=\"chip\"\u003eType: \u003cb\u003efieldbus\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eProtocol: \u003cb\u003ePROFIBUS-DP\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eSupply: \u003cb\u003e24 V DC\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eUse: \u003cb\u003ediagnostics \/ control\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eWidth: \u003cb\u003e22.5 mm\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eConnection: \u003cb\u003eD-sub 9\u003c\/b\u003e\u003c\/span\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/header\u003e\n\n\u003cdiv class=\"wrap\"\u003e\n\n \u003csection\u003e\n \u003ch2\u003eOverview \u0026amp; Function\u003c\/h2\u003e\n \u003cp\u003eThe \u003cstrong\u003ePilz 773732 (PNOZ mc3p Profibus 2)\u003c\/strong\u003e is a PROFIBUS-DP fieldbus communication expansion module for the PNOZmulti classic configurable safety system. It connects the safety controller to a PROFIBUS network, exchanging non-safe diagnostics and standard process data with a higher-level PLC for visualisation and control. The safety logic itself remains internal to the PNOZmulti system.\u003c\/p\u003e\n \u003cp\u003eSupplied by \u003cstrong\u003eSHLY-PLC, an independent industrial-automation distributor\u003c\/strong\u003e. Brand and model are used for identification only; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/p\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eKey Ratings at a Glance\u003c\/h2\u003e\n \u003cdiv class=\"cards\"\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eModule type\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003efieldbus \u003csmall\u003ecomm\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eProtocol\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003ePROFIBUS \u003csmall\u003eDP\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eSupply voltage\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e24 \u003csmall\u003eV DC\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eWidth\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e22.5 \u003csmall\u003emm\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n\u003cdiv class=\"cards\" style=\"margin-top:12px;\"\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eDimensions HxWxD\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e94x22.5x119 \u003csmall\u003emm\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eNet weight\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e0.119 \u003csmall\u003ekg\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eConnection\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003eD-sub 9 \u003csmall\u003efemale\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003ePosition\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e1 fieldbus \u003csmall\u003eper base\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eI\/O Channel Map \u0026amp; Safety Function\u003c\/h2\u003e\n \u003cdiv class=\"iomap\"\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e1\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003ePROFIBUS-DP\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eD-sub 9 female, to the higher-level PLC \/ fieldbus master\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e1\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eBase bus\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eInternal expansion bus to the PNOZmulti base unit\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003eN\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eVirtual I\/O\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eDiagnostics and standard process data mapped in the Configurator\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e1\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eStatus\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eLEDs for bus state, supply and faults\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"rednote\"\u003eThe PNOZ mc3p transfers \u003cstrong\u003enon-safety-related diagnostics and process data\u003c\/strong\u003e over PROFIBUS-DP. The safety functions continue to be performed by the PNOZmulti base unit and its safe I\/O (up to \u003cstrong\u003ePL e \/ Cat. 4 \/ SIL CL 3\u003c\/strong\u003e). Max. one fieldbus module per base unit.\u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eOrder Number Breakdown\u003c\/h2\u003e\n \u003cp style=\"font-family:Consolas,monospace;font-size:16.5px;margin:4px 0 12px;\"\u003e773732\u003c\/p\u003e\n \u003cdiv class=\"code-flow\"\u003e\n \u003cdiv class=\"seg\"\u003e\n\u003cb\u003e773\u003c\/b\u003e\u003cspan\u003ePNOZmulti classic communication family\u003c\/span\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"seg\"\u003e\n\u003cb\u003e732\u003c\/b\u003e\u003cspan\u003ePNOZ mc3p Profibus 2 - PROFIBUS-DP fieldbus module\u003c\/span\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eConnects PNOZmulti classic to a PROFIBUS-DP network for diagnostics and standard data\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eFieldbus connection\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eD-sub 9 female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eScope of delivery\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eCommunication module; PROFIBUS bus cable \/ terminator ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003ePower Supply \u0026amp; I\/O Data\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\u003cth colspan=\"2\" style=\"background:var(--accent-soft);\"\u003ePower supply\u003c\/th\u003e\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSupply type\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eNominal supply voltage\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eModule supply\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eVia the base unit expansion bus\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eLED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\u003cth colspan=\"2\" style=\"background:var(--accent-soft);\"\u003eInputs \u0026amp; outputs\u003c\/th\u003e\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePROFIBUS-DP (D-sub 9), non-safe data exchange\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eProcess data\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eStandard \/ diagnostic data to a higher-level PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSafety role\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eNo direct safe I\/O; safety logic stays in the base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePNOZmulti Configurator\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eSafety Characteristics\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003ePerformance level (PL)\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eUp to PL e (EN ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eUp to Category 4\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSIL \/ SIL CL\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eUp to SIL CL 3 (IEC 62061) \/ SIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003ePFH\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eConfiguration-dependent; see Configurator report\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eConfigured via PNOZmulti Configurator; mounted on base unit bus\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eConfiguration position\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eSet in the Configurator; terminator fitted to last module\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSensor \/ load connection\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePer module I\/O channel map\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eLEDs for supply, input and output states\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eMechanical \u0026amp; Environmental Data\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eDimensions W x H x D\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e\u003cb\u003e22.5 x 94 x 121 mm\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eNet weight\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eapprox. 0.15 ... 0.25 kg (model-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eDIN rail (35 mm), snapped onto the base unit \/ rail\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eTerminal type\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePlug-in; screw or spring-loaded terminal set ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eIP20 (installed in cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eAmbient temperature, operation\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eAmbient temperature, storage \/ transport\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e-20 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e≤ 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eVibration \/ shock\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePer IEC 60068-2-6 \/ IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePPO \/ ABS, UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eCompliance, Approvals \u0026amp; Standards\u003c\/h2\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eApprovals \/ certifications\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eCE · cULus Listed · TÜV · BG \/ BG-PRÜF · EAC (Eurasian) · KOSHA · KCC · UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eFunctional safety standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN ISO 13849-1 (PL e \/ Cat. 4) · IEC 62061 (SIL CL 3) · IEC 61508 (SIL 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eEMC standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN 61000-6-2 (immunity) · EN 61000-6-4 (emission) · EN 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eGeneral standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN 60204-1 · EN ISO 12100 · IEC 60364\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cfooter\u003e\n 773732 · PNOZ mc3p Profibus 2 · PNOZmulti classic · PROFIBUS-DP fieldbus communication module · 24 V DC · D-sub 9 · 22.5 mm · Independently supplied by SHLY-PLC\n \u003c\/footer\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/body\u003e","brand":"Pilz","offers":[{"title":"New","offer_id":46157546193149,"sku":"773732","price":548.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/773732-F1-515Wx515H.jpg?v=1745823294","url":"https:\/\/shly-plc.com\/products\/pilz-773732-safety-relay","provider":"SHLY-PLC","version":"1.0","type":"link"}