{"product_id":"pilz-773603-sensor-distribution-box","title":"Pilz 773603 Sensor Distribution Box","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003cmeta name=\"google\" content=\"notranslate\"\u003e\n\u003ctitle\u003e773603 — 773603 - PDP67 F 4 Code Passive Junction Box\u003c\/title\u003e\n\u003cstyle\u003e\n.desc-model-title{display:block;border:none;outline:none;text-transform:none;padding:0;background:none;margin:inherit;}\n.desc-model-title {font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}\n\n :root{\n --abb-red:#E2001A; --abb-dark:#1A1A1A; --ink:#222; --muted:#5f6368;\n --line:#e3e5e8; --bg:#f5f6f8; --card:#fff; --accent-soft:#fdecec;\n --blue:#4a6cf7; --info-bg:#eef3ff; --info-line:#4a6cf7; --info-ink:#22345e;\n }\n *{box-sizing:border-box;}\n body{margin:0;font-family:\"Segoe UI\",Arial,Helvetica,sans-serif;color:var(--ink);background:var(--bg);line-height:1.55;font-size:15px;}\n .wrap{max-width:1080px;margin:0 auto;padding:0 0 64px;}\n header.hero{background:linear-gradient(120deg,#1a1a1a,#333);color:#fff;padding:38px 0 30px;margin-bottom:24px;border-bottom:6px solid var(--abb-red);}\n header.hero .wrap{padding:0 24px;}\n .brand{display:flex;align-items:center;gap:12px;margin-bottom:18px;}\n .brand .logo{background:var(--abb-red);color:#fff;font-weight:800;letter-spacing:1px;padding:4px 10px;border-radius:3px;font-size:20px;}\n .brand .fam{font-size:14px;color:#cfcfcf;text-transform:uppercase;letter-spacing:2px;}\n h1{font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}\n .subtitle{color:#bdbdbd;font-size:15px;margin:0 0 18px;}\n .chips{display:flex;flex-wrap:wrap;gap:8px;}\n .chip{background:rgba(255,255,255,.1);border:1px solid rgba(255,255,255,.25);border-radius:20px;padding:4px 14px;font-size:13px;color:#f1f1f1;}\n .chip b{color:#fff;}\n section{background:var(--card);border:1px solid var(--line);border-radius:10px;padding:22px 26px;margin:18px 0;}\n h2{font-size:19px;margin:0 0 14px;padding-bottom:10px;border-bottom:2px solid var(--abb-red);display:inline-block;}\n h3{font-size:15px;margin:18px 0 8px;color:var(--abb-dark);}\n table{border-collapse:collapse;width:100%;margin:8px 0 6px;font-size:14px;}\n th,td{text-align:left;padding:9px 12px;border-bottom:1px solid var(--line);vertical-align:top;}\n th{background:#f0f1f3;font-weight:600;color:#333;}\n tr:last-child td,tr:last-child th{border-bottom:none;}\n td.val{font-weight:500;}\n .unit{color:var(--muted);font-weight:400;}\n .grid2{display:grid;grid-template-columns:1fr 1fr;gap:0 28px;}\n .cards{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:6px 0 4px;}\n .stat{border:1px solid var(--line);border-radius:8px;padding:14px;background:#fafbfc;}\n .stat .k{font-size:12px;color:var(--muted);text-transform:uppercase;letter-spacing:.6px;margin-bottom:6px;}\n .stat .v{font-size:20px;font-weight:700;color:var(--abb-dark);}\n .stat .v small{font-size:12px;font-weight:500;color:var(--muted);}\n .infonote{background:var(--info-bg);border-left:4px solid var(--info-line);padding:12px 16px;border-radius:0 6px 6px 0;font-size:14px;color:var(--info-ink);margin:0;}\n .infonote b{color:#16264d;}\n .rednote{background:var(--accent-soft);border-left:4px solid var(--abb-red);padding:10px 14px;border-radius:0 6px 6px 0;font-size:13.5px;margin:12px 0 0;color:#5a2020;}\n .iomap{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:8px 0 4px;}\n .iocard{border:1px solid var(--line);border-radius:8px;padding:14px;background:#fafbfc;text-align:center;}\n .iocard .num{font-size:28px;font-weight:800;color:var(--abb-red);line-height:1.1;}\n .iocard .lbl{font-size:12px;color:var(--muted);text-transform:uppercase;letter-spacing:.6px;margin-top:6px;}\n .iocard .sub{font-size:12.5px;color:#444;margin-top:4px;}\n .code-flow{display:flex;flex-wrap:wrap;gap:8px;margin:8px 0 14px;}\n .seg{border:1px solid var(--line);border-radius:8px;padding:8px 12px;background:#fafbfc;font-size:13px;}\n .seg b{display:block;font-family:Consolas,monospace;font-size:14.5px;color:var(--abb-red);}\n .seg span{color:var(--muted);font-size:12px;}\n footer{text-align:center;color:var(--muted);font-size:12px;margin-top:26px;}\n @media (max-width:820px){.grid2{grid-template-columns:1fr;}.cards{grid-template-columns:repeat(2,1fr);}.iomap{grid-template-columns:1fr 1fr;}}\n @media print{body{background:#fff;font-size:12px;}section{break-inside:avoid;border:none;border-top:1px solid #ccc;border-radius:0;}header.hero{print-color-adjust:exact;-webkit-print-color-adjust:exact;}}\n\u003c\/style\u003e\n\n\n\n\u003cheader class=\"hero\"\u003e\n \u003cdiv class=\"wrap\"\u003e\n \u003cdiv class=\"brand\"\u003e\n \u003cspan class=\"logo\"\u003ePILZ\u003c\/span\u003e\n \u003cspan class=\"fam\"\u003ePDP67 | passive junction \/ distribution box | field wiring\u003c\/span\u003e\n \u003c\/div\u003e\n \u003ch2 class=\"desc-model-title\"\u003e773603 — PDP67 F 4 Code Passive Junction Box\u003c\/h2\u003e\n \u003cp class=\"subtitle\"\u003ePassive 4-way junction \/ distribution box for PSENcode, PSENslock and PSENini safety sensors · field-wiring IP67 box\u003c\/p\u003e\n \u003cdiv class=\"chips\"\u003e\n \u003cspan class=\"chip\"\u003eType: \u003cb\u003epassive junction\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eCircuits: \u003cb\u003e4 code\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eFor use with: \u003cb\u003ePSENcode \/ slock \/ ini\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eHousing: \u003cb\u003eIP67 field\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eFunction: \u003cb\u003epassive distributor\u003c\/b\u003e\u003c\/span\u003e\n \u003cspan class=\"chip\"\u003eSupply: \u003cb\u003epassive (24 V loop)\u003c\/b\u003e\u003c\/span\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/header\u003e\n\n\u003cdiv class=\"wrap\"\u003e\n\n \u003csection\u003e\n \u003ch2\u003eOverview \u0026amp; Function\u003c\/h2\u003e\n \u003cp\u003eThe \u003cstrong\u003ePilz 773603 (PDP67 F 4 code)\u003c\/strong\u003e is a passive junction \/ distribution box used to wire up to four Pilz coded safety sensors (PSENcode, PSENslock or PSENini) on the PDP67 field bus. As a passive junction it carries the sensor supply and signal wiring out to the safety switches and back to the decentralised PDP67 input station, simplifying field cabling on safety gates and guard doors.\u003c\/p\u003e\n \u003cp\u003eSupplied by \u003cstrong\u003eSHLY-PLC, an independent industrial-automation distributor\u003c\/strong\u003e. Brand and model are used for identification only; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/p\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eKey Ratings at a Glance\u003c\/h2\u003e\n \u003cdiv class=\"cards\"\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003epassive \u003csmall\u003ejunction\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eSensor circuits\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e4 \u003csmall\u003ecode\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eCompatible sensors\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003ePSENcode \u003csmall\u003e\/ slock \/ ini\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eHousing\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003eIP67 \u003csmall\u003efield\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n\u003cdiv class=\"cards\" style=\"margin-top:12px;\"\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eActive electronics\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003enone \u003csmall\u003e(passive)\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eMounting\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003efield \u003csmall\u003emount\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eFunction\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003edistribution \/ \u003csmall\u003ejunction\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eSystem\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003ePDP67 \/ PNOZmulti\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eI\/O Channel Map \u0026amp; Safety Function\u003c\/h2\u003e\n \u003cdiv class=\"iomap\"\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e4\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eSensor drops\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eConnects up to 4 coded safety sensors (PSENcode \/ slock \/ ini)\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e1\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eBus trunk\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eBack to the PDP67 decentralised input station\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003e0\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eActive I\/O\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003ePassive box - no electronics, no switching\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"iocard\"\u003e\n\u003cdiv class=\"num\"\u003eIP67\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eHousing\u003c\/div\u003e\n\u003cdiv class=\"sub\"\u003eRugged field distributor housing\u003c\/div\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"rednote\"\u003eThe PDP67 F 4 code is a \u003cstrong\u003epassive distribution box\u003c\/strong\u003e: it carries sensor wiring and supply only. The safe evaluation is performed by the connected PNOZmulti system via the PDP67 input station, rated up to \u003cstrong\u003ePL e \/ Cat. 4 \/ SIL CL 3\u003c\/strong\u003e.\u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eOrder Number Breakdown\u003c\/h2\u003e\n \u003cp style=\"font-family:Consolas,monospace;font-size:16.5px;margin:4px 0 12px;\"\u003e773603\u003c\/p\u003e\n \u003cdiv class=\"code-flow\"\u003e\n \u003cdiv class=\"seg\"\u003e\n\u003cb\u003e773\u003c\/b\u003e\u003cspan\u003ePDP67 field accessory family\u003c\/span\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"seg\"\u003e\n\u003cb\u003e603\u003c\/b\u003e\u003cspan\u003ePDP67 F 4 code - passive 4-way junction for coded safety sensors\u003c\/span\u003e\n\u003c\/div\u003e\n \u003c\/div\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eFor use with\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePSENcode, PSENslock and PSENini coded safety sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eRequires\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eA PDP67 decentralised input station on the PDP-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eScope of delivery\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePassive junction box; cables ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003ePower Supply \u0026amp; I\/O Data\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\u003cth colspan=\"2\" style=\"background:var(--accent-soft);\"\u003ePower supply\u003c\/th\u003e\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePassive junction \/ distribution box (no active electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePass-through of sensor supply from the PDP67 station\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSignals\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eCarries coded-sensor signal wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eNo active LEDs (passive device)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\u003cth colspan=\"2\" style=\"background:var(--accent-soft);\"\u003eInputs \u0026amp; outputs\u003c\/th\u003e\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSensor connections\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eUp to 4 coded safety sensor drops\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eOutputs\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eNone (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eSystem interface\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePDP67 field bus to input station\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eNone - passive wiring accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eSafety Characteristics\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eSafety rating\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEvaluated by the connected PNOZmulti (up to PL e \/ Cat. 4 \/ SIL CL 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eActive function\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eNone - passive distribution only\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePassive junction box\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003ePFH\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eDetermined by the safety circuit, not this passive device\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eSimplifies field cabling of multiple coded safety sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eCompatible sensors\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePSENcode, PSENslock, PSENini\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eField \/ guard-door mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eVia the connected PNOZmulti system\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eMechanical \u0026amp; Environmental Data\u003c\/h2\u003e\n \u003cdiv class=\"grid2\"\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eIP67 field distribution box\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eDirect on machine \/ guard\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePassive junction\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eAmbient temperature, operation\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eAmbient temperature, storage \/ transport\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e-20 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd class=\"val\"\u003e≤ 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eVibration \/ shock\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePer IEC 60068-2-6 \/ IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd class=\"val\"\u003ePPO \/ ABS, UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n \u003ch2\u003eCompliance, Approvals \u0026amp; Standards\u003c\/h2\u003e\n \u003ctable\u003e\n \u003ctr\u003e\n\u003cth\u003eApprovals \/ certifications\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eCE · cULus Listed · TÜV · BG \/ BG-PRÜF · EAC (Eurasian) · KOSHA · KCC · UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eFunctional safety standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN ISO 13849-1 (PL e \/ Cat. 4) · IEC 62061 (SIL CL 3) · IEC 61508 (SIL 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eEMC standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN 61000-6-2 (immunity) · EN 61000-6-4 (emission) · EN 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eGeneral standards\u003c\/th\u003e\n\u003ctd class=\"val\"\u003eEN 60204-1 · EN ISO 12100 · IEC 60364\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/table\u003e\n \u003c\/section\u003e\n\n \u003csection\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cfooter\u003e\n 773603 · PDP67 F 4 Code · passive 4-way junction for PSENcode \/ PSENslock \/ PSENini · IP67 field box · PDP67 \/ PNOZmulti · Independently supplied by SHLY-PLC\n \u003c\/footer\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/body\u003e","brand":"Pilz","offers":[{"title":"New","offer_id":46157545767165,"sku":"773603","price":139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/60ec5ad42b4cc4a628293596fad93d03.jpg?v=1790565196","url":"https:\/\/shly-plc.com\/products\/pilz-773603-sensor-distribution-box","provider":"SHLY-PLC","version":"1.0","type":"link"}