{"product_id":"pilz-772101-pnoz-m-b1-pnozmulti-2-base-unit","title":"Pilz PNOZ m B1 PNOZmulti 2 Configurable Safety Controller Base Unit","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePilz · PNOZmulti 2\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e772101\u003c\/b\u003e is the Pilz \u003cb\u003ePNOZ m B1\u003c\/b\u003e — a base unit of the PNOZmulti 2 configurable safety system, expandable and fitted with an Ethernet interface with switch and USB 20 memory. Supply voltage U1 24 V DC, power consumption DC 18.5 W, 4 test pulse outputs, 2 Ethernet interfaces (RJ45) at 10 MBit\/s and 100 MBit\/s.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage U1\u003c\/span\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ePower consumption DC\u003c\/span\u003e\u003cstrong\u003e18.5 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEthernet interface\u003c\/span\u003e\u003cstrong\u003e2 × RJ45, 10\/100 MBit\/s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProtection type\u003c\/span\u003e\u003cstrong\u003eIP54 mounting \/ IP20 housing \/ IP20 terminals\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProduct identification and specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOfficial product name\u003c\/th\u003e\n\u003ctd\u003ePNOZ m B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer reference (order no.)\u003c\/th\u003e\n\u003ctd\u003e772101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGTIN\u003c\/th\u003e\n\u003ctd\u003e4046548069419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct series\u003c\/th\u003e\n\u003ctd\u003ePNOZmulti 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePurpose of U1\u003c\/th\u003e\n\u003ctd\u003eSupply of the system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage U1\u003c\/th\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption DC\u003c\/th\u003e\n\u003ctd\u003e18.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of test pulse outputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet IP address\u003c\/th\u003e\n\u003ctd\u003e169.254.60.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector type\u003c\/th\u003e\n\u003ctd\u003eETHERNET int. RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet transmission rate\u003c\/th\u003e\n\u003ctd\u003e10 MBit\/s, 100 MBit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Ethernet interfaces\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB memory\u003c\/th\u003e\n\u003ctd\u003eUSB 20 memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironmental data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature standard\u003c\/th\u003e\n\u003ctd\u003eEN 60068-2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 - 60 °C (forced convection in control cabinet off: 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature standard\u003c\/th\u003e\n\u003ctd\u003eEN 60068-2-1\/-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic suitability\u003c\/th\u003e\n\u003ctd\u003eEN 60068-2-30, EN 60068-2-78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity rating\u003c\/th\u003e\n\u003ctd\u003e93 % r. h. at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondensation permitted?\u003c\/th\u003e\n\u003ctd\u003eNot permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerm. operating height\u003c\/th\u003e\n\u003ctd\u003eASL 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration to standard\u003c\/th\u003e\n\u003ctd\u003eEN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcc. shock\u003c\/th\u003e\n\u003ctd\u003e15 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance \u0026amp; creepage dist. to\u003c\/th\u003e\n\u003ctd\u003eEN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type standard\u003c\/th\u003e\n\u003ctd\u003eEN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type, mounting\u003c\/th\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type, housing\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal protection type\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eHorizontal on top hat rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDIN-rail dimensions\u003c\/th\u003e\n\u003ctd\u003eTop hat rail 35 x 7,5 EN 50022, recess width 27 mm (35 x 7,5 and 35 x 15 EN\/IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eLower section PC, front plate PC, upper part PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection terminal\u003c\/th\u003e\n\u003ctd\u003eScrew terminal, cage clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal style\u003c\/th\u003e\n\u003ctd\u003eplug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlex. cond. c\/s AWG\u003c\/th\u003e\n\u003ctd\u003e24 - 12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eHeight 101.4 mm \/ Width 45 mm \/ Depth 120.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNet 209 g \/ Gross 219 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eCompliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eCE, UKCA, cULus Listed, TÜV, EAC (Eurasian)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication range\u003c\/th\u003e\n\u003ctd\u003eFail-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues are taken from the official Pilz product page for this order number and from the Pilz PNOZmulti 2 technical catalogue (document 1006421-EN-01). Parameters not published for this order number are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eManufacturer documents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pilz.com\/en-INT\/eshop\/product\/772101\"\u003eOfficial product page (Pilz eShop)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pilz.com\/download\/open\/OM_PNOZ_m_B1_1003790-EN-12.pdf\"\u003eOperating Manual PNOZ m B1 (1003790-EN-12)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pilz.com\/download\/open\/PNOZmulti_2_Techn_Catalogue_1006421-EN-01.pdf\"\u003eTechnical Catalogue PNOZmulti 2 (1006421-EN-01)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pilz.com\/download\/open\/EU-EC-Declaration_of_Conformity_1006264-CE-13.pdf\"\u003eEU\/EC-Declaration of Conformity (1006264-CE-13)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pilz.com\/download\/open\/UK-Declaration_of_Conformity_1006264-UK-12.pdf\"\u003eUK Declaration of Conformity UKCA (1006264-UK-12)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe PNOZmulti 2 base unit is the device-level element of a configurable safety system: it takes the field signals and the 24 V DC control supply, evaluates the safety logic and drives the safe outputs listed above. It is installed horizontally on a top hat mounting rail inside the control cabinet, where the mounting area is rated IP54 while the housing and terminals are rated IP20.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in control panels and machine builds where a documented, compact replacement is required. Record the catalog number and the firmware version from the nameplate of the installed unit before specifying a like-for-like spare — for 772101 the manufacturer explicitly flags the firmware compatibility note above.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Pilz 772101\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupply voltage U1: \u003cstrong\u003e24 V DC\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eProtection type, mounting: \u003cstrong\u003eIP54\u003c\/strong\u003e — The housing and terminals are rated IP20.\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: \u003cstrong\u003e0 - 60 °C\u003c\/strong\u003e — Forced convection in the control cabinet must be off for the full range.\u003c\/li\u003e\n\u003cli\u003eStorage temperature: \u003cstrong\u003e-25 - 70 °C\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDatasheets and compliance documents are available on request; quote the full catalog number 772101 when enquiring.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about 772101\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat is the official product name for catalog number 772101?\u003c\/p\u003e\n\u003cp\u003eIt is the Pilz PNOZ m B1, a base unit of the PNOZmulti 2 configurable safety system (GTIN 4046548069419).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat ambient and storage temperature ranges does the manufacturer list for 772101?\u003c\/p\u003e\n\u003cp\u003eThe ambient temperature range is 0 - 60 °C (forced convection in the control cabinet off: 55 °C) and the storage temperature range is -25 - 70 °C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat protection types are listed for 772101?\u003c\/p\u003e\n\u003cp\u003eIP54 for the mounting area, IP20 for the housing and IP20 for the terminals, in accordance with EN 60529.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat supply voltage does 772101 need?\u003c\/p\u003e\n\u003cp\u003eU1 is 24 V DC for the system supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for 772101?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number 772101, the required quantity and a readable photo of the nameplate including the firmware version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Pilz","offers":[{"title":"New","offer_id":46157541835005,"sku":"772101","price":210.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1200Wx1200H-F-PNOZ-m-B1-772101-F1-3c-800.jpg?v=1790125658","url":"https:\/\/shly-plc.com\/products\/pilz-772101-pnoz-m-b1-pnozmulti-2-base-unit","provider":"SHLY-PLC","version":"1.0","type":"link"}