{"product_id":"phoenix-contact-1357840-router","title":"Phoenix Contact 1357840 Gateway","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePhoenix Contact · Gateway\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e1357840\u003c\/b\u003e is a Phoenix Contact circuit breaker with Breaking capacity Icu\/Ics Ethernet in RJ45 twisted pair; Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eBreaking capacity Icu\/Ics\u003c\/span\u003e\u003cstrong\u003eEthernet in RJ45 twisted pair\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 61131-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting\u003c\/span\u003e\u003cstrong\u003e35 mm DIN rail (IEC 60715)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\/Ics\u003c\/th\u003e\n\u003ctd\u003eEthernet in RJ45 twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e10\/100\/1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth\u003eProtocols\u003c\/th\u003e\n\u003ctd\u003eESP tunnel \/ ESP transport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e388 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal wire size\u003c\/th\u003e\n\u003ctd\u003e0.2 mm² ... 1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+55 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e5 % ... 95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Phoenix Contact Gateway specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003ePhoenix Contact Gateway variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eMounting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e1357840\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-2297620-data-interface\"\u003e2297620\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-2316364-protocol-converter\"\u003e2316364\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-2700197-security-router\"\u003e2700197\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 1357840 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Phoenix Contact 1357840\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePhoenix Contact 1357840\u003c\/strong\u003e — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1357840; record the nameplate data of the unit being replaced before selecting an equivalent.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0...+55 °C (IEC 60068-2-1)\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eCertifications: \u003cstrong\u003eCE, UL, cULus\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity Icu\/Ics: \u003cstrong\u003eEthernet in RJ45 twisted pair\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cstrong\u003e35 mm DIN rail (IEC 60715)\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a discontinued unit, match function and electrical ratings rather than the label alone.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about 1357840\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering 1357840, which rated speed entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe rated speed entry quoted above is 10\/100\/1000 Mbps. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the protocols data for 1357840?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Phoenix Contact 1357840 as ESP tunnel \/ ESP transport. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor 1357840, what does the specification table state about certifications?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists certifications = CE, UL, cULus for Phoenix Contact 1357840. Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 1357840 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 1357840 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the 1357840 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number 1357840 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":71130876543229,"sku":"1357840","price":2369.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1357840.webp?v=1794987261","url":"https:\/\/shly-plc.com\/products\/phoenix-contact-1357840-router","provider":"SHLY-PLC","version":"1.0","type":"link"}