{"product_id":"phoenix-contact-1019990-miniature-circuit-breaker","title":"Phoenix Contact 1019990 Miniature Circuit Breaker","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePhoenix Contact · DIN-rail power supply\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e1019990\u003c\/b\u003e is a Phoenix Contact circuit breaker with Rated current Ie 50 A; Tripping characteristic B \/ C \/ D (IEC 60947-2); Number of poles 1 \/ 2 \/ 3 \/ 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current Ie\u003c\/span\u003e\u003cstrong\u003e50 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTripping characteristic\u003c\/span\u003e\u003cstrong\u003eB \/ C \/ D (IEC 60947-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003cstrong\u003e1 \/ 2 \/ 3 \/ 4 (IEC 60947-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eBreaking capacity Icu\/Ics\u003c\/span\u003e\u003cstrong\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current Ie\u003c\/th\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand Uimp\u003c\/th\u003e\n\u003ctd\u003e4 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\/Ics\u003c\/th\u003e\n\u003ctd\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTripping characteristic\u003c\/th\u003e\n\u003ctd\u003eB \/ C \/ D (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 3 \/ 4 (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e120,800 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal wire size\u003c\/th\u003e\n\u003ctd\u003e1 mm² ... 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25...+60 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e48 h, 95% RH, 40°C (IEC 60068-2-78)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Phoenix Contact DIN-rail power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003ePhoenix Contact DIN-rail power supply variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eTripping characteristic\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eBreaking capacity Icu\/Ics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e1019990\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (IEC 60947-2)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-1019976-miniature-circuit-breaker\"\u003e1019976\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (IEC 60947-2)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-1019979-miniature-circuit-breaker\"\u003e1019979\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (IEC 60947-2)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-1019983-miniature-circuit-breaker\"\u003e1019983\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (IEC 60947-2)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 1019990 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the 50 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Phoenix Contact 1019990\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePhoenix Contact 1019990\u003c\/strong\u003e — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 1019990; verify the catalog number against your bill of materials before requesting a quotation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e — Check this value against the nameplate of the installed unit before ordering.\u003c\/li\u003e\n\u003cli\u003eRated torque: \u003cstrong\u003e2 Nm\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e-25...+60 °C (IEC 60068-2-1)\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eWeight: \u003cstrong\u003e120,800 g\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDatasheets and compliance documents are available on request; quote the full catalog number when enquiring.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about 1019990\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under enclosure rating for catalog number 1019990?\u003c\/p\u003e\n\u003cp\u003eFor 1019990, enclosure rating is given as IP20 (IEC 60529). Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering 1019990, which tripping characteristic entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe tripping characteristic entry quoted above is B \/ C \/ D (IEC 60947-2). Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the terminal wire size data for 1019990?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Phoenix Contact 1019990 as 1 mm² ... 35 mm². Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the 1019990 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number 1019990 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 1019990 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 1019990 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":71131079540989,"sku":"1019990","price":348.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1019990.webp?v=1794986775","url":"https:\/\/shly-plc.com\/products\/phoenix-contact-1019990-miniature-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}