{"product_id":"phoenix-contact-0914141-thermal-magnetic-circuit-breaker","title":"Phoenix Contact 0914141 Circuit Breaker","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003ePhoenix Contact · circuit breaker\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e0914141\u003c\/b\u003e is a Phoenix Contact circuit breaker with Rated current Ie 6 A; Tripping characteristic B \/ C \/ D (EN 60934 \/ UL 1077); Number of poles 1 \/ 2 \/ 3 \/ 4 (EN 60934 \/ UL 1077). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current Ie\u003c\/span\u003e\u003cstrong\u003e6 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTripping characteristic\u003c\/span\u003e\u003cstrong\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNumber of poles\u003c\/span\u003e\u003cstrong\u003e1 \/ 2 \/ 3 \/ 4 (EN 60934 \/ UL 1077)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRated operational voltage\u003c\/span\u003e\u003cstrong\u003e65 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current Ie\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd\u003e65 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand Uimp\u003c\/th\u003e\n\u003ctd\u003e4 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\/Ics\u003c\/th\u003e\n\u003ctd\u003e6 kA \/ 10 kA (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTripping characteristic\u003c\/th\u003e\n\u003ctd\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 3 \/ 4 (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e0.6 ... 0.8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e69.74 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal wire size\u003c\/th\u003e\n\u003ctd\u003e0.2 mm² ... 6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25...+60 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e240 h, 95 % RH, 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003ePhoenix Contact circuit breaker variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eTripping characteristic\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eBreaking capacity Icu\/Ics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e0914141\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e65 V DC\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-0914400-thermal-magnetic-circuit-breaker\"\u003e0914400\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-0914439-thermal-magnetic-circuit-breaker\"\u003e0914439\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/phoenix-contact-0914497-thermal-magnetic-circuit-breaker\"\u003e0914497\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003ctd\u003eB \/ C \/ D (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003ctd\u003e6 kA \/ 10 kA (EN 60934 \/ UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 0914141 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 65 V DC — and switches or conditions the load within the 6 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Phoenix Contact 0914141\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePhoenix Contact 0914141\u003c\/strong\u003e — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0914141; verify the catalog number against your bill of materials before requesting a quotation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: \u003cstrong\u003e69.74 g\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eCertifications: \u003cstrong\u003eCE, UL, cULus\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eNumber of poles: \u003cstrong\u003e1 \/ 2 \/ 3 \/ 4 (EN 60934 \/ UL 1077)\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cstrong\u003e35 mm DIN rail (IEC 60715)\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about 0914141\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under enclosure rating for catalog number 0914141?\u003c\/p\u003e\n\u003cp\u003eFor 0914141, enclosure rating is given as IP20 (IEC 60529). Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering 0914141, which humidity entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe humidity entry quoted above is 240 h, 95 % RH, 40 °C. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the rated insulation voltage Ui data for 0914141?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Phoenix Contact 0914141 as 440 V (IEC 60947-2). Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the 0914141 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number 0914141 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 0914141 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 0914141 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Phoenix Contact","offers":[{"title":"Default Title","offer_id":71131083211005,"sku":"0914141","price":296.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/0914141.webp?v=1794986672","url":"https:\/\/shly-plc.com\/products\/phoenix-contact-0914141-thermal-magnetic-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}