{"product_id":"omron-e5accx4a5m000-new-digital-temperature-controller","title":"Omron E5ACCX4A5M000 New Product Digital Temperature Controller","description":"\u003cdiv style=\"max-width:100%;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;font-size:15px;line-height:1.6;overflow-wrap:anywhere;\"\u003e\n\u003ch1 style=\"font-size:22px;line-height:1.3;margin:0 0 12px;color:#1a1a1a;\"\u003eE5ACCX4A5M000 New Product Digital Temperature Controller | Omron\u003c\/h1\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003eOmron E5ACCX4A5M000\u003c\/strong\u003e is a new product digital temperature controller. The listed technical data shows a supply of MELSEC is a registered trademark of Mitsubishi Electric Corporation, communication via *1. For heater burnout alarms, the heater current will be measured, rated IP66, Rear case: IP20, Terminals: IP00, based on the manufacturer's datasheet. It is supplied by SHLY-PLC, an independent industrial-automation distributor: every unit is visually inspected and functionally checked before dispatch, held in ready stock and shipped worldwide for maintenance, spares and retrofit use. Share your application or existing part number and our team will confirm fitment and comparable in-stock alternatives.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D32030;color:#1a1a1a;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003ePower supply voltage 5 VDC:\u003c\/strong\u003e MELSEC is a registered trademark of Mitsubishi Electric Corporation..\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eNumber of outputs:\u003c\/strong\u003e 1 (only on models with a transfer output).\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eCRC-16 with Modbus:\u003c\/strong\u003e *4. The value is 35 ms for a control period of 0.1 s or 0.2 s..\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eDegree of protection Front panel:\u003c\/strong\u003e IP66, Rear case: IP20, Terminals: IP00.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eAmbient temperature:\u003c\/strong\u003e −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 120 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D32030;color:#1a1a1a;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp style=\"font-size:13px;color:#666666;margin:0 0 4px;\"\u003eTechnical parameters compiled from the manufacturer data sheet and reference documentation.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed;margin:6px 0 18px;font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#D32030;color:#ffffff;padding:7px 11px;text-align:left;vertical-align:top;word-break:break-word;font-weight:700;\"\u003eTechnical Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eType Designation\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eUSB-Serial Conversion Cable\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eWhen Digital Temperature Controllers are connected,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e±0.2 VDC (Supplied from USB-Serial Conversion\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003ecommunications support the copying.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003ePower Supply\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eHeater Burnout Alarms and SSR Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eBus power (Supplied from USB host\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003efrom the Digital Temperature Controller that is\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCommunications buffer 217 bytes\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eRelays (Reference Values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCurrent consumption 450 mA max.\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e*1. A Temperature Controller with version 1.1 or higher is required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePower supply voltage 5 VDC\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eMELSEC is a registered trademark of Mitsubishi Electric Corporation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eUse a high-power port for the USB port.\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eCT input (for heater Models with detection for single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eInputs \u0026amp; Outputs\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eAnalog input\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e0.01% to 99.99% FS (in units of 0.01% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e1 (only on models with a transfer output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e85% to 110% of rated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e1.6 W max. at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eSimple transfer output accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e±0.3% FS max.*2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eCommunication \u0026amp; Interfaces\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003efrom the Digital Temperature Controller that is\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCRC-16 with Modbus\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e*4. The value is 35 ms for a control period of 0.1 s or 0.2 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e*3. The value is 30 ms for a control period of 0.1 s or 0.2 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eProtocol\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e*1. For heater burnout alarms, the heater current will be measured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eBaud rate *\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e*1. For heater burnout alarms, the heater current will be measured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCharacter height\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003ePV: 10.5 mm, SV: 5.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eDegree of protection Front panel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eIP66, Rear case: IP20, Terminals: IP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eApprox. 120 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eEnvironmental\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eAmbient operating humidity 10% to 80%\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e50 Hz, 98 m\/s2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e−10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eCompliance, Approvals \u0026amp; Standards\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eConformed standards\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eEN 61010-1 (IEC 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eIndication accuracy Platinum resistance thermometer\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e20 MΩ min. (at 500 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eCompatibility \u0026amp; Cross-References\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eModel variants, options and firmware revisions can affect fitment. Before ordering the Omron E5ACCX4A5M000 new product digital temperature controller, share your existing part number or project requirements and our team will cross-reference comparable in-stock Omron units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D32030;color:#1a1a1a;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eIndustrial automation, machine building and process control applications.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eMaintenance, spares and retrofit use on installed production equipment.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eControl cabinets and automated cells requiring reliable industrial components.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eWorldwide replacement and upgrade projects across manufacturing industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D32030;color:#1a1a1a;\"\u003eWarranty\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e E5ACCX4A5M000 is stocked for prompt shipment; contact us for current quantity and lead time.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eInspection \u0026amp; testing:\u003c\/strong\u003e each unit is visually inspected and functionally checked before packing.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e in-stock orders placed before 14:00 ship the same business day; standard worldwide delivery is about 5-8 business days, express shipping is available, and orders over $500 ship free.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eWarranty \u0026amp; returns:\u003c\/strong\u003e covered by our supplier warranty and standard returns policy; contact our team for full terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"font-size:13px;line-height:1.5;color:#555555;background:#f7f7f8;border-left:3px solid #D32030;padding:9px 12px;margin:12px 0;\"\u003eIndependent supplier: Omron part E5ACCX4A5M000 is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/div\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #D32030;color:#1a1a1a;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What condition is the E5ACCX4A5M000 supplied in?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: Each E5ACCX4A5M000 is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: How quickly can the E5ACCX4A5M000 ship?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: Can you confirm compatibility or a replacement for the E5ACCX4A5M000?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.\u003c\/p\u003e\n\u003cp style=\"font-size:12px;color:#888888;text-align:center;margin:18px 0 4px;\"\u003eE5ACCX4A5M000 · Technical reference data · Independently supplied by SHLY-PLC\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"New","offer_id":46140183838973,"sku":"E5ACCX4A5M000","price":504.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/E5ACCX4A5M000.jpg?v=1742612333","url":"https:\/\/shly-plc.com\/products\/omron-e5accx4a5m000-new-digital-temperature-controller","provider":"SHLY-PLC","version":"1.0","type":"link"}