{"product_id":"micro800-2-point-analog-output-plug-in","title":"Allen-Bradley 2080-OF2 - Micro800 2 Point Analog Output Plug-In","description":"\u003cp\u003e\u003cstrong\u003eMicro800 2 Point Analog Output Plug-In\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e2080 Micro800 System, 2-ch V\/I Analog Output Unipolar 0-10V\/0-20mA (non-isolated)\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Isolation:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Status Indication:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e -20¡­65 ¡ãC (-4¡­149 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue inputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue outputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitive load, max:\u003c\/strong\u003e 0.1 ¦ÌF @ voltage outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to channel isolation:\u003c\/strong\u003e Non-isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent load on voltage output, max:\u003c\/strong\u003e 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent range:\u003c\/strong\u003e 0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\/A Conversion rate (all channels), max:\u003c\/strong\u003e 2.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e IEC 61000-4-4: ¡À2kV @ 5kHz on shielded ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e CISPR 11 (IEC 61000-6-4): Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive load, max:\u003c\/strong\u003e 0.01 mH @ current outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, current:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput group to bus isolation:\u003c\/strong\u003e Non-isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistance thermometer:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistor:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal, configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, thermocouple:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, voltage:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad range on voltage output:\u003c\/strong\u003e \u0026gt; 1k ? @ 10V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting torque:\u003c\/strong\u003e 0.2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-linearity:\u003c\/strong\u003e ¡À0.1% @ in % full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonoperating temperature:\u003c\/strong\u003e -40...85 ¡ãC (-40...185 ¡ãF), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American temperature code:\u003c\/strong\u003e T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of analogue outputs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen and short-circuit protection:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20...65 ¡ãC (-4...149 ¡ãF): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput count range:\u003c\/strong\u003e 0 to 65535\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, current:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput error:\u003c\/strong\u003e Voltage: ¡À1.5% @ over full temperature range, -20...65¡ãC (-4...149¡ãF), Current: ¡À2.0% @ over full temperature range, -20...65¡ãC (-4...149¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput overvoltage protection:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, voltage:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall accuracy:\u003c\/strong\u003e Voltage terminal: ¡À1% full scale @ 25¡ãC, Current terminal: ¡À1% full scale @ 25¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e \u0026lt;60mA @ 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e IEC 61000-4-3: 10V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V\/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V\/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended maximum shielded cable length:\u003c\/strong\u003e 10 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ¡À0.1% @ in % full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistive load on current output:\u003c\/strong\u003e 0...500 ? (includes wire resistance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution of the analogue outputs:\u003c\/strong\u003e 12 bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL according to IEC 61508:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep response to 63%:\u003c\/strong\u003e 5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e IEC 61000-4-5: ¡À2 kV line-earth(CM) on shielded ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 65 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal screw torque:\u003c\/strong\u003e 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage ranges:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire size:\u003c\/strong\u003e Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 ¡ãC (194 ¡ãF) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 ¡ãC (194 ¡ãF) insulation maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46279546306813,"sku":"2080-OF2","price":120.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/2080-OF2--ISO.jpg?v=1785383366","url":"https:\/\/shly-plc.com\/products\/micro800-2-point-analog-output-plug-in","provider":"Lianyou PLC","version":"1.0","type":"link"}