{"product_id":"lkg5001v","title":"Keyence LK-G5001V | Industrial Automation Component","description":"\u003ch2\u003eKeyence LK-G5001V\u003c\/h2\u003e\n\u003cp\u003eMain controller: Built-in type, NPN LK-G5001V\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eModel\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eLK-G5001V *1 *2; Separate type\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eLK-G5001\/LK-HD500; Type\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eMain controller; Sensor head compatibility\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eCompatible; No. of connectable sensor heads\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e2; Display\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eMinimum display unit\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eLK-HD500\u003c\/td\u003e\n\u003ctd\u003e0.001 µm; Display range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eLK-HD500\u003c\/td\u003e\n\u003ctd\u003e±999.999 µm to ±9,999.99 mm (7 settings selectable); Display cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eLK-HD500\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 times\/sec.; Display interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eDisplay port\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eEither the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected; LED indicator\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eLASER ON; Terminal block\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eAnalog output voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003e±10 V output, Output impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ω; Analog current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003e4 to 20 mA, Maximum load resistance\u003c\/td\u003e\n\u003ctd\u003e350 Ω; No. of analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e2; TIMING 1 input\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNon-voltage input *3; RESET 1 input; Auto-zero 1 input; Laser control input\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNon-voltage input *4; Laser remote input\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNon-voltage input; Alarm output\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNPN open-collector output; General comparator output; Expansion connector\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eTIMING input\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNon-voltage input; RESET input; Auto-zero input; Program switching input; Binary selection input; Alarm output\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eNPN open-collector output; Comparator output; Binary output; RS-232C interface\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eBaud rate\u003c\/td\u003e\n\u003ctd\u003e9,600 to 115,200 bps Data length: 8 bits, Stop bit length: 1 bit, Parity: None\/even\/odd; USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUSB 2.0 Hi-Speed compliant *5; Ethernet interface\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e100Base-TX\/10Base-T *6; EtherNet\/IP™interface\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eCyclic communication (implicit messaging) Message communication (explicit messaging)\u003c\/td\u003e\n\u003ctd\u003eUCMM and Class3 Number of connections: 32 Complies with conformance test version CT14 *7; PLC-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eThe following PLCs are supported\u003c\/td\u003e\n\u003ctd\u003eMitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet\/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link; Head expansion unit connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUp to 10 head expansion units can be connected to one main controller; Expansion unit connector\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eEither of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected; Power supply\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003ePower supply voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e24 VDC ±10 %; Maximum current consumption\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e0.6 A or less with 1 head\/3.5 A or less with 12 heads; Environmental resistance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eAmbient temperature\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eWhen one or less head expansion unit is connected\u003c\/td\u003e\n\u003ctd\u003e0 to +50 °C 32 to 122 °F . When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F .; Relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e35 to 85 % RH (No condensation); Weight\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:bold;\"\u003eApprox. 600 g; *1 NPN open-collector output rating\u003c\/td\u003e\n\u003ctd\u003e50 mA max. (40 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. *2 Part of the input\/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables\/external devices. For details, refer to \"Precautions on wiring\" in the User's Manual. *3 This input is applied to all of the synchronized OUT. *4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.) When the laser class 2\/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited. *5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down. *6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units. *7 The EtherNet\/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed. EtherNet\/IP™ is supported by the latest controllers. For details on which controllers support EtherNet\/IP™ , contact your nearest KEYENCE office.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eLK-G5001V, Main controller: Built-in type, NPN in LK-G5000 series by KEYENCE America.\u003c\/p\u003e","brand":"Keyence","offers":[{"title":"New","offer_id":46137043583229,"sku":"LK-G5001V","price":498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/AS_4538_L.jpg?v=1742532891","url":"https:\/\/shly-plc.com\/products\/lkg5001v","provider":"Lianyou PLC","version":"1.0","type":"link"}