{"product_id":"honeywell-stg775-e1gs1a-1-a-ch0-11s-a-10a0-00-0000-pressure-transmitter","title":"Honeywell STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 Pressure Transmitter","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eHoneywell · Pressure transmitter\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eSTG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000\u003c\/b\u003e is a Honeywell industrial component with Supply voltage Pending confirmation from the official Honeywell data sheet; Enclosure rating Meets Type 4X \/ IP66 \/ IP67. All stainless-steel housing is optional.; Operating temperature Pending confirmation from the official Honeywell data sheet. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003eDE: 15 to 49.3 VDC; HART: 10.8 to 42.4 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eMeets Type 4X \/ IP66 \/ IP67. All stainless-steel housing is optional.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003cstrong\u003e-40 to +85 deg C (Operating), -55 to +120 deg C (Storage)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting\u003c\/span\u003e\u003cstrong\u003eMounting Bracket Carbon Steel (Zinc-plated) or 304 or 316 Stainless Steel, See Figures 3 \u0026amp; 4\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003eDE: 15 to 49.3 VDC; HART: 10.8 to 42.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication ports\u003c\/th\u003e\n\u003ctd\u003e4 to 20 mA, Honeywell DE, HART (v7.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eMounting Bracket Carbon Steel (Zinc-plated) or 304 or 316 Stainless Steel, See Figures 3 \u0026amp; 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eMeets Type 4X \/ IP66 \/ IP67. All stainless-steel housing is optional.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +85 deg C (Operating), -55 to +120 deg C (Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Honeywell Pressure transmitter specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eHoneywell Pressure transmitter variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eMounting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eSTG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-stg770-a1gc1a-1-a-adc-11s-a-00a0-00-0000-hmi-panel\"\u003eSTG770-A1GC1A-1-A-ADC-11S-A-00A0-00-0000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-stg770-a1gc1a-1-a-ahc-11s-a-50a0-00-0000-hmi-panel\"\u003eSTG770-A1GC1A-1-A-AHC-11S-A-50A0-00-0000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-stg770-e1gn1a-1-a-afb-16s-b-11a0-f7-0000-hmi-panel\"\u003eSTG770-E1GN1A-1-A-AFB-16S-B-11A0-F7-0000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePending confirmation from the official Honeywell data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 is the device-level element in a Honeywell industrial component installation. It receives the field signals and control supply listed above — Pending confirmation from the official Honeywell data sheet — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides Pending confirmation from the official Honeywell data sheet support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Honeywell STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHoneywell STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000\u003c\/strong\u003e — Operator panel for visualisation, parameter setting and alarm handling on a control cabinet door or console. The figures below are taken from the specification table on this page for catalog number STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication ports: \u003cstrong\u003e4 to 20 mA, Honeywell DE, HART (v7.0)\u003c\/strong\u003e — Check this value against the nameplate of the installed unit before ordering.\u003c\/li\u003e\n\u003cli\u003eResponse time: \u003cstrong\u003ePending confirmation from the official Honeywell data sheet\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eCertifications: \u003cstrong\u003ePending confirmation from the official Honeywell data sheet\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eSupply voltage: \u003cstrong\u003eDE: 15 to 49.3 VDC; HART: 10.8 to 42.4 VDC\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000, what does the specification table state about operating temperature?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists operating temperature = Pending confirmation from the official Honeywell data sheet for Honeywell STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under supply voltage for catalog number STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000?\u003c\/p\u003e\n\u003cp\u003eFor STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000, supply voltage is given as Pending confirmation from the official Honeywell data sheet. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000, which response time entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe response time entry quoted above is Pending confirmation from the official Honeywell data sheet. Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71134814077181,"sku":"STG775-E1GS1A-1-A-CH0-11S-A-10A0-00-0000","price":6552.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/65537f7db5a147feb686fa4cae4316a9_tplv-5jbd59dj06-image_3c6326ca-3412-4477-a572-d20861148daa.png?v=1789057592","url":"https:\/\/shly-plc.com\/products\/honeywell-stg775-e1gs1a-1-a-ch0-11s-a-10a0-00-0000-pressure-transmitter","provider":"SHLY-PLC","version":"1.0","type":"link"}