{"product_id":"honeywell-900cr1500-hmi-operator-interface","title":"Honeywell 900CR1500 HMI Panel","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eHoneywell · HMI panel\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e900CR1500\u003c\/b\u003e is a Honeywell HMI panel with Screen size Analog resistive; Supply voltage 24 V DC (IEC 60950-1); Enclosure rating IP65 (IEC 60529). It is used in machine operator panels, control cabinets, local HMI stations where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eScreen size\u003c\/span\u003e\u003cstrong\u003eAnalog resistive\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 60950-1)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP65 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth\u003eScreen size\u003c\/th\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5.17 kg (11.41 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mount \/ DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP65 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacklight life\u003c\/th\u003e\n\u003ctd\u003e50,000 h typical, field replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTouch type\u003c\/th\u003e\n\u003ctd\u003eresistive or projective capacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the Honeywell HMI panel specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eHoneywell HMI panel variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eScreen size\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eSupply voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e900CR1500\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-900cr10-00-hmi-operator-interface\"\u003e900CR10-00\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-sp3000-wr-temperature-sensor\"\u003eSP3000-WR\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-sps-r360d-nbms0101-smart-rotary-position-sensor\"\u003eSPS-R360D-NBMS0101\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe 900CR1500 is the device-level element in a Honeywell HMI panel installation. It receives the field signals and control supply listed above — 24 V DC (IEC 60950-1) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in machine operator panels, control cabinets, local HMI stations, where the unit is matched to the original catalog number and the enclosure provides Panel mount \/ DIN rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Honeywell 900CR1500\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHoneywell 900CR1500\u003c\/strong\u003e — Operator panel for visualisation, parameter setting and alarm handling on a control cabinet door or console. The figures below are taken from the specification table on this page for catalog number 900CR1500; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP65 (IEC 60529)\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eBacklight life: \u003cstrong\u003e50,000 h typical, field replaceable\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eTouch type: \u003cstrong\u003eresistive or projective capacitive\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0...+50 °C\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCross-check the ratings above with the installed device before confirming the order.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about 900CR1500\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering 900CR1500, which screen size entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe screen size entry quoted above is Analog resistive. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the enclosure rating data for 900CR1500?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Honeywell 900CR1500 as IP65 (IEC 60529). Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor 900CR1500, what does the specification table state about weight?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists weight = 5.17 kg (11.41 lbs) for Honeywell 900CR1500. Compare it with the nameplate of the installed unit before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for 900CR1500?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number 900CR1500, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Honeywell 900CR1500.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 900CR1500 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 900CR1500 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71134525096189,"sku":"900CR1500","price":5770.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/65537f7db5a147feb686fa4cae4316a9_tplv-5jbd59dj06-image_78ceb9ec-23b5-4b83-b43e-9f8dd3b6a152.png?v=1789056907","url":"https:\/\/shly-plc.com\/products\/honeywell-900cr1500-hmi-operator-interface","provider":"SHLY-PLC","version":"1.0","type":"link"}