{"product_id":"fx3u-4lc","title":"Mitsubishi FX3U-4LC | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX3U-4LC\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX3U-4LC\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX5U, FX5UC, FX3U (V2.20 and later), FX3UC (V2.20 or later) [Connecting to the FX5U, FX5UC CPU module] FX5-CNV-BUS or FX5-CNV-BUSC is required to connect to the FX5U\/FX5UC CPU module. Select one of the modules according to the system configuration. [Connecting to the connector-type PLC] The FX2NC-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 points (Taken from either the input or output points of the PLC.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - No. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Input type - Thermocouple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK, J, R, S, E, T, B, N (JIS C 1602-1995), PLII, W5Re\/W26Re, U, L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Input type - Resistance temperature detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-wire Pt100 JIS C 1604-1997 3-wire JPt100 JIS C 1604-1981 2-wire or 3-wire Pt1000 JIS C 1604-1997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Input type - Micro voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 mV DC, 0 to 100 mV DC A different input can be selected for each channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Measurement precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C When K type thermocouple Input range 500℃ or more, ±(0.3% of input value)±1 digit Ambient temperature: 0 to 55°C When K type thermocouple input range 500°C or more, ±(0.7% of input value)±1 digit Measurement accuracy differs depending on the type of input, and the input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Cold contact temperature compensation error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.0°C (When ambient temperature is 0 to 55°C) However, within ± 2.0°C while input value is -150 to -100°C \/ within ± 3.0°C while input value is -200 to -150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Sampling period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ms\/4ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Input impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MΩ or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Current detector (CT) input (Number of input points)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Current detector (CT) input (Measurement precision)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarger one between ±5% of input value and ±2 A (Excluding precision of current detector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Current detector (CT) input (Current detector)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCTL-12-S36-8, CTL-12-S56-10, CTL-6-P-H (manufactured by U.R.D. Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Current detector (CT) input (Sampling period)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Control operation period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ms\/4ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-position control, PID control, Heating\/cooling PID control, Cascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - K\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 1300°C\/-100 to 2400°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 1200°C\/-100 to 2100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 400°C\/-300 to 700°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1700°C\/0 to 3200°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1700°C\/0 to 3200°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 1000°C\/0 to 1800°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1800°C\/0 to 3000°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1300°C\/0 to 2300°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - PLII\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1200°C\/0 to 2300°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - U\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 600°C\/-300 to 700°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 900°C\/0 to 1600°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - W5Re\/W26Re\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2300°C\/0 to 3000°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - Micro voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 mV DC, 0 to 100 mV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - Pt100 (3-wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 600°C\/-300 to 1100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - JPt100 (3-wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200 to 500°C\/-300 to 900°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Temperature measuring range - Pt1000 (2-wire\/3-wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200.0 to 650.0°C\/-328 to 1184°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Heater disconnection detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm is detected by buffer memory (Variable within range from 0.0 to 100.0 A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Self-diagnostics function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustment data check, input value check, watch dog timer check.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTemperature sensor\/Temperature control - Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in EEPROM (Number of times of overwrite: 100,000 times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNPN open collector transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated load voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum load voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum load current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLeak current in OFF status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 V (when energized with 100 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. voltage drop when ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 100.0 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl output cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 24 V DC +20% -15% 50 mA It is necessary to connect a 24 V DC power supply to the terminal block.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC 160 mA The power is internally supplied from the 5 V DC power supply unit of the main unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX5U, FX5UC, FX3U (V2.20 and later), FX3UC (V2.20 or later) [Connecting to the FX5U, FX5UC CPU module] FX5-CNV-BUS or FX5-CNV-BUSC is required to connect to the FX5U\/FX5UC CPU module. Select one of th\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137198412029,"sku":"FX3U-4LC","price":234.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/232805_11054f7f-a43d-441b-9652-39278077bd88.jpg?v=1742537721","url":"https:\/\/shly-plc.com\/products\/fx3u-4lc","provider":"Lianyou PLC","version":"1.0","type":"link"}