{"product_id":"fx3u-32mt-es-a","title":"Mitsubishi FX3U-32MT\/ES-A | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX3U-32MT\/ES-A\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX3U-32MT\/ES\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program repetitive operation system (dedicated LSI) with interruption function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput\/output control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBatch processing system (when END instruction is executed), Input\/output refresh instruction and pulse catch function are provided.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgramming language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay symbol system + step-ladder system (SFC notation possible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Max. memory capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64000 steps Up to 64000 steps, including comment and file registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Built-in memory capacity\/type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64000-step (Symbolic information can be stored. Supported in Ver. 3.00 or later.)\/RAM (backed up by built-in lithium battery) Battery life: Approx. 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Memory cassette (Option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[Ver. 3.00 or later] ・FX3U-FLROM-1M (2000\/4000\/8000\/16000\/32000\/64000 steps, loader function, symbolic information can be stored in the dedicated area (1300 kB).) [Ver. 2.20] ・FX3U-FLROM-64L (2000\/4000\/8000\/16000\/32000\/64000 steps, loader function) ・FX3U-FLROM-64 (2000\/4000\/8000\/16000\/32000\/64000 st\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Writing function during running\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvided (Program can be modified while the PLC is running.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassword protection provided (with entry code function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eReal-time clock - Clock function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 1980 to 2079 (with correction for leap year) 2- or 4-digit year, accuracy within ±45 seconds\/month at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[Ver. 2.30 or later] ・Sequence instructions: 29 ・Step-ladder instructions: 2 [Former than Ver. 2.30] ・Sequence instructions: 27 ・Step-ladder instructions: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e219 kinds 498 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.065 μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.642 μs to several hundred μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(1) 248 points or less (Extension combined number) (1)+(2) total number of points is 256 or less.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(2) 248 points or less (Extension combined number) (1)+(2) total number of points is 256 or less.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Remote I\/O number of points - AnyWireASLINK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(3) 128 points or less *The total number of remote I\/O points in CC-Link and AnyWireASLINK must be 256 points or less.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Remote I\/O number of points - AS-i\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(3) 248 points or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Total number of points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(1)+(2)+(3) total number of points is 384 or less. (Extension combined number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Input relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X367: 248 points (octal) Extension combined number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Output relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY000 to Y367: 248 points (octal) Extension combined number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM0 to M499: 500 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For keeping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM500 to M1023: 524 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For keeping (battery backup fixed area)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM1024 to M7679: 6656 points This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8000 to M8511: 512 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - Initial state\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS0 to S9: 10 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS10 to S499: 490 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For keeping 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS500 to S899: 400 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For annunciator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS900 to S999: 100 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For keeping 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1000 to S4095: 3096 points This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT0 to T191: 192 points (0.1 to 3,276.7 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms (for subroutine\/interruption subroutine)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT192 to T199: 8 points (0.1 to 3,276.7 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 10 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT200 to T245: 46 points (0.01 to 327.67 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 1 ms accumulating type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT246 to T249: 4 points (0.001 to 32.767 sec) This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms accumulating type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT250 to T255: 6 points (0.1 to 3,276.7 sec) This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 1 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT256 to T511: 256 points (0.001 to 32.767 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC0 to C99: 100 points (Counting from 0 to 32,767) The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up (keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100 to C199: 100 points (Counting from 0 to 32,767) The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 32 bits up or down\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC200 to C219: 20 points (Counting from -2,147,483,648 to +2,147,483,647) The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 32 bits up or down (keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC220 to C234: 15 points (Counting from -2,147,483,648 to +2,147,483,647) The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD0 to D199: 200 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for keeping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD200 to D511: 312 points The retentive status can be changed by parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for keeping (File register)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD512 to D7999: 7488 points (D1000 and later can be set as file register points in 500-point units) This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD8000 to D8511: 512 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV0 to V7, Z0 to Z7: 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Extension register\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[16 bits] R0 to R32767: 32768 points This retentive status is a battery backup fixed area. The area characteristics cannot be changed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Extension file register\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[16 bits] ER0 to ER32767: 32768 points Usable only when memory cassette is mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - For branching of JUMP and CALL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP0 to P4095: 4096 points (For CJ instructions and CALL instructions, P63 jumps to END instruction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - Input interruption and input delay interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI00□ to I50□: 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - Timer interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI6□□ to I8□□: 3 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - Counter interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI010 to I060: 6 points (For HSCS instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Nesting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[For master control] N0 to N7: 8 points (For MC instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Decimal number (K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: -32,768 to +32,767 32 bits: -2,147,483,648 to +2,147,483,647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Hexadecimal number (H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Real number (E)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 bits: -1.0 × 2 128 to -1.0 × 2 -126 , 0, 1.0 × 2 -126 to 1.0 × 2 128 Decimal-point and exponential notations are possible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 100 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable supply voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFrequency rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation can be continued upon occurrence of instantaneous power failure for 10 ms or less. When the supply voltage is 200 V AC, the time can be change to 10 to 100 ms by editing the user program.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable instantaneous power failure time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V 3.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A max. 5 ms or less\/100 V AC, 65 A max. 5 ms or less\/200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 W These power consumption values are maximum values which apply to the main unit's 24 V DC service power supply when there are input\/output extension blocks and special function units\/blocks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003e24 V DC service power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA or less The power supply is not for external use. The current capacity specified above is for the input\/output extension blocks, special function blocks, special adapters and expansion boards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003e5 V DC built-in power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X005: 3.9 kΩ X006, X007: 3.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X005: 6 mA\/24 V DC X006, X007: 7 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X005: 3.5 mA or more X006, X007: 4.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms X000 to X017 (up to the main unit built-in number) have built-in digital filters, which can be changed to 0 to 60 ms in 1 ms increments using the application instructions or D8020. The following is applied when 0 is set. X000 to X005: 5μs X006, X007: 50μs X010 to X017: 200μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOFF input sensitivity current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact input Sink: NPN open collector transistor Source: PNP open collector transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput response time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal form\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED is lit when input is on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication of input operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput circuit configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor\/sink output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A or less\/1 output point The total load current per common terminal should be the following value. 1 output point\/common terminal: 0.5 A or less 4 output points\/common terminal: 0.8 A or less 8 output points\/common terminal: 1.6 A or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e－\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Resistance load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or less\/30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Inductive load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMin. load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY000 to Y002: 5 μs or less\/10 mA or more (5-24 V DC) Y003 or more: 0.2 ms or less\/200 mA or more (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOpen circuit leakage current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY000 to Y002: 5 μs or less\/10 mA or more (5-24 V DC) Y003 or more: 0.2 ms or less\/200 mA or more (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eResponse time - OFF→ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen photocoupler is driven, LED on panel is lit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003e  - Built-in pulse output and positioning function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 3 independent axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of control axes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSequence program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible main units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e・Pulse Y Output (PLSY) ・Acceleration\/Deceleration Setup (PLSR) Pulse output form: Pulse train (The direction is controlled with the sequence.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePulse output instruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e・ABS Absolute current value read ([D]ABS) ・DOG Search Zero Return [DSZR] ・Zero Return [ZRN] (no DOG search function) Decelerates when near-point DOG is ON, Stops when near-point DOG is OFF. (This is different from the zero return operation by counting the zero point signal.) ・Variable speed pulse ou\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform dielectric withstand voltage test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 1.5 kV AC for 1 min Between 24 V DC service power supply connected to input terminal (24 V DC) and ground \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform insulation resistance test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester Between 24 V DC service power supply connected to input t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eStored program repetitive operation system (dedicated LSI) with interruption function\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137196708093,"sku":"FX3U-32MT\/ES-A","price":97.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/206143.jpg?v=1742537661","url":"https:\/\/shly-plc.com\/products\/fx3u-32mt-es-a","provider":"Lianyou PLC","version":"1.0","type":"link"}