{"product_id":"fx2n-2ad","title":"Mitsubishi FX2N-2AD | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX2N-2AD\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX2N-2AD\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX0N, FX1N, FX2N, FX3G, FX3U, FX2NC, FX3GC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the FX3GC\/FX3UC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 points (Taken from either the input or output points of the PLC.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V to 10 V DC, 0 V to 5 V DC(Input resistance 200kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mA to 20 mA DC (Input resistance 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Number of input channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.5 V, +15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2 mA, +60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Digital output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits, binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V to 10 V DC: 2.5 mV (10 V × 1\/4000) 0 V to 5 V DC: 1.25 mV (5 V × 1\/4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 μA (16 mA × 1\/4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% (±0.1 V) for 10 V full scale Same for 0 V to 5 V DC input (±0.1V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% (±0.16 mA) for 16 mA full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - A\/D conversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 ms\/1 channel(Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 5 V DC 20 mA (internal power supply from PLC main unit) 24 V DC ±10% 50 mA (internal power supply from PLC main unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX0N, FX1N, FX2N, FX3G, FX3U, FX2NC, FX3GC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the \u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137195790589,"sku":"FX2N-2AD","price":43.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/102869.jpg?v=1742537629","url":"https:\/\/shly-plc.com\/products\/fx2n-2ad","provider":"Lianyou PLC","version":"1.0","type":"link"}