{"product_id":"fx1s-30mr-es-ul","title":"Mitsubishi FX1S-30MR-ES\/UL | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX1S-30MR-ES\/UL\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX1S-30MR-ES\/UL\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program repetitive operation system with interruption function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput\/output control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBatch processing system (when END instruction is executed), Input\/output refresh instruction and pulse catch function are provided.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgramming language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay symbol system + step-ladder system (SFC notation possible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Max. memory capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 steps Up to 2000 steps, including comment and file registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Built-in memory capacity\/type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000-step EEPROM (memory backup not required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Writing function during running\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvided (Program can be modified while the PLC is running.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassword protection provided (with entry code function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eReal-time clock - Clock function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 1980 to 2079 (with correction for leap year), 2- or 4-digit year, accuracy 45 seconds\/month at 25 °C *Precaution for clock function The current time of the built-in clock is backed up by a high-capacity capacitor (built-in). The large-capacity capacitor (built-in) fully charges in 30 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e・Sequence instructions: 27 ・Step-ladder instructions: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApplied instructions: 85 kinds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 to 0.7 μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 μs to several hundred μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points or less (in accordance with the input specification) Extension is impossible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 points or less (in accordance with the output specification) Extension is impossible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Total number of points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 points or less (in accordance with the I\/O specification) Extension is impossible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Input relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X017 16 points (octal) Extension is impossible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Output relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY000 to Y015 14 points (octal) Extension is impossible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM0 to M383 384 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For keeping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM384 to M511 128 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8000 to M8255 256 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - Initial state\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS0 to S9 10 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For keeping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll points held during power failure (S0 to S127) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT0 to T62 63 points (0.1 to 3,276.7 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 10 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen M8028 is turned ON, T32 to T62 (31 points) can be changed to a 10ms timer (0.01 to 327. 67 sec.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 1 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT63 1 point (0.001 to 32.767 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - Others\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable as analog timers VR1: D8030, VR2: D8031 2 points (0 to 255)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC0 to C15 16 points (Counting from 0 to 32,767)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up (keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC16 to C31 16 points (Counting from 0 to 32,767) (EEPROM keep) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD0 to D127 128 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for keeping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD128 to D255 128 points (EEPROM keep) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - File register (keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD1000 to D2499 1500 points (Settable in file register in 500-point units.) (EEPROM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD8000 to D8255 256 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV0 to V7, Z0 to Z7: 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - For branching of JUMP and CALL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP0 to P63 64 points (For CJ instructions and CALL instructions, P63 jumps to END instruction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - Input interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI00□ to I50□: 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Nesting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[For master control] N0 to N7: 8 points (For MC instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Decimal number (K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: -32,768 to +32,767 32 bits: -2,147,483,648 to +2,147,483,647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Hexadecimal number (H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 100 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable supply voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFrequency rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation can be continued upon occurrence of instantaneous power failure for 10 ms or less.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable instantaneous power failure time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A max. 5 ms or less\/100 V AC, 25 A max. 5 ms or less\/200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 W Includes input current (7 or 5 mA per point).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003e24 V DC service power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms X000 to X017 (up to the main unit built-in number) have built-in digital filters, which can be changed to 0 to 15 ms in 1 ms increments using the application D8020. When 0 is specified, X000 and X001 are 10 μs, and X002 to X017 are 50 μs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOFF input sensitivity current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact input Sink: NPN open collector transistor Source: PNP open collector transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput response time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal form\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED is lit when input is on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput circuit insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 14 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication of input operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC 30 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A or less\/1 output point 8 A or less\/COM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 2 mA (reference value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Resistance load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e－\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Inductive load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e－\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMin. load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOpen circuit leakage current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eResponse time - OFF→ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen power is applied to relay coil, LED is lit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -20 to 70°C (-4 to 158 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 to 85%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform dielectric withstand voltage test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 1.5 kV AC for 1 min Between 24 V DC service power supply connected to input terminal (24 V DC) and ground \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform insulation resistance test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester Between 24 V DC service power supply connected to input t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eStored program repetitive operation system with interruption function\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137199296765,"sku":"FX1S-30MR-ES\/UL","price":63.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/FX1S-30MR-ES-UL.jpg?v=1742537750","url":"https:\/\/shly-plc.com\/products\/fx1s-30mr-es-ul","provider":"Lianyou PLC","version":"1.0","type":"link"}