{"product_id":"fx1n-24mr-es-ul","title":"Mitsubishi FX1N-24MR-ES\/UL | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX1N-24MR-ES\/UL\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX1N-24MR-ES\/UL\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program repetitive operation system with interruption function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput\/output control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBatch processing system (when END instruction is executed), Input\/output refresh instruction and pulse catch function are provided.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgramming language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay symbol system + step-ladder system (SFC notation possible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Max. memory capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8000 steps Up to 8000 steps, including comment and file registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Built-in memory capacity\/type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8000 EEPROM (memory backup not required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Memory cassette (Memory board)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX1N-EEPROM-8L (8000 steps EEPROM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Writing function during running\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvided (Program can be modified while the PLC is running.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram memory - Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassword protection provided (with entry code function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eReal-time clock - Clock function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 1980 to 2079 (with correction for leap year), 2- or 4-digit year, accuracy within ±45 seconds\/month at 25°C *Precaution for clock function The current time of the built-in clock is backed up by a high-capacity capacitor (built-in). The large-capacity capacitor (built-in) fully charges in 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e・Sequence instructions: 27 ・Step-ladder instructions: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eKinds of instructions - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApplied instructions: 89 kinds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Basic instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 to 0.7 μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Applied instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 μs to several hundred μs\/instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 points or less (Extension combined number) Note that the total for I\/O is 128 points or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - No. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 points or less (Extension combined number) Note that the total for I\/O is 128 points or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Remote I\/O number of points (CC-Link)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 points or less including mounted I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input\/output points - Total number of points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 points or less (Extension combined number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Input relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX000 to X177 128 points (octal) Extension-combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Input\/output relay - Output relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY000 to Y177 128 points (octal) Extension-combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM0 to M383 384 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For keeping (EEPROM keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM384 to M511 128 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For keeping (capacitor keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM512 to M1535 1024 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping device may not hold its sta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Auxiliary relay - For special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8000 to M8255 256 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - Initial state (EEPROM keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS0 to S9 10 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For keeping (EEPROM keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS10 to S127 118 points * Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - State - For keeping (capacitor keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS128 to S999 872 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping device may not hold its state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT0 to T199 200 points (0.1 to 3,276.7 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 10 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT200 to T245: 46 points (0.01 to 327.67 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 1 ms accumulating type (capacitor keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT246 to T249 4 points (0.001 to 32.767 sec) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping device ma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - 100 ms accumulating type (capacitor keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT250 to T255 6 points (0.1 to 3,276.7 sec) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping device may\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Timer (on delay) - Others\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable as analog timers VR1: D8030, VR2: D8031 2 points (0 to 255)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC0 to C15 16 points (Counting from 0 to 32,767)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bits up (EEPROM keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC16 to C31 16 points (Counting from 0 to 32,767) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 16 bit up\/down (capacitor keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC32 to C199 168 points (Counting from 0 to 32,767) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping de\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 32 bits up or down\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC200 to C219 20 points (Counting from -2,147,483,648 to +2,147,483,647)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Counter - 32 bit up\/down (capacitor keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC220 to C234 15 points (Counting from -2,147,483,648 to +2,147,483,647) *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for general\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD0 to D127 128 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - For 16 bits keep (EEPROM keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD128 to D255 128 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The PLC power must be on for at least 5 minutes to accurately keep the data in the EEPROM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bit for keeping (capacitor keeping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD256 to D7999 7744 points *Precaution for keeping area The keeping area and non-keeping area are fixed. (Cannot be changed with parameter) The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The capacitor keeping device may not hold its sta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - File register (keep)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD1000 to D7999 Maximum 7000 points (Can be set as file registers in units of 500 points from D1000 in the program area (EEPROM) using parameters.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for special\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD8000 to D8255 256 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Data register (32 bits when paired) - 16 bits for index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV0 to V7, Z0 to Z7: 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - For branching of JUMP and CALL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP0 to P127 128 points (For CJ instructions and CALL instructions, P63 jumps to END instruction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Pointer - Input interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI00□ to I50□: 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDevice - Nesting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[For master control] N0 to N7: 8 points (For MC instructions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Decimal number (K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: -32,768 to +32,767 32 bits: -2,147,483,648 to +2,147,483,647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant - Hexadecimal number (H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 100 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable supply voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFrequency rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation can be continued upon occurrence of instantaneous power failure for 10 ms or less.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAllowable instantaneous power failure time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A max. 5 ms or less\/100 V AC, 50 A max. 5 ms or less\/200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W Includes input current (7 or 5 mA per point).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA This is irrelevant for the connection of extension blocks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003e24 V DC service power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 14 points (16) The value in parentheses is the number of occupied points. The difference in the number of valid points is an empty number.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput impedance - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X000 to X007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON input sensitivity current - X010 or more\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms X000 to X007 have built-in digital filters, which can be changed to 0 to 15 ms in 1 ms increments using the application D8020. When 0 is specified, X000 and X001 are 10 μs, and X002 to X017 are 50 μs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOFF input sensitivity current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact input Sink: NPN open collector transistor Source: PNP open collector transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput response time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput signal form\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED is lit when input is on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput circuit insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 10 points (16) The value in parentheses is the number of occupied points. The difference in the number of valid points is an empty number.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication of input operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC 30 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A or less\/1 output point 8 A or less\/COM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 2 mA (reference value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Resistance load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e－\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Inductive load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e－\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMin. load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOpen circuit leakage current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eResponse time - OFF→ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen power is applied to relay coil, LED is lit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131°F) when operating and -20 to 70°C (-4 to 158°F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 to 85%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform dielectric withstand voltage test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 1.5 kV AC for 1 min Between 24 V DC service power supply connected to input terminal (24 V DC) and ground \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePerform insulation resistance test at the following voltage between each terminals and the main unit ground terminal. Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester Between 24 V DC service power supply connected to input t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eStored program repetitive operation system with interruption function\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137199526141,"sku":"FX1N-24MR-ES\/UL","price":70.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/fx-1n-24_1.jpg?v=1742537757","url":"https:\/\/shly-plc.com\/products\/fx1n-24mr-es-ul","provider":"Lianyou PLC","version":"1.0","type":"link"}