{"product_id":"fr-e840-0380-4-60","title":"Mitsubishi FR-E840-0380-4-60 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FR-E840-0380-4-60\u003c\/h2\u003e\n\u003cp\u003eInverters-FREQROL FR-E840-0380-4-60\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 400 V class Standard model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840-0380-4-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInverter capacity (kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *2 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *2 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) *7 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.0 (38.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) *7 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *3 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *3 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Voltage *4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Regenerative braking - Brake transistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Regenerative braking - Maximum brake torque (ND reference) *5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input AC voltage and frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 480 V, 50\/60 Hz (537 to 679 VDC *9 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible AC voltage fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323 to 528 V, 50\/60 Hz (457 to 740 VDC *9 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible frequency fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *8 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *8 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *8 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *8 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *6 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *6 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *6 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *6 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective structure - IEC 60529\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCooling system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApprox. mass (kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft-PWM control\/High carrier frequency PWM control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable among V\/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM sensorless vector control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10 .)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015 Hz\/60 Hz at 0 to 10 V\/12 bits (terminals 2 and 4) 0.03 Hz\/60 Hz at 0 to 5 V\/11 bits or 0 to 20 mA\/11 bits (terminals 2 and 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 % or less of the set output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Voltage\/frequency characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase frequency can be set from 0 to 590 Hz. Constant-torque\/variable-torque pattern can be selected (with induction motor only).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Starting torque - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V\/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 200 % at 0.3 Hz (0.1K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control) 200 % at 0 Hz (0.1K to 3.7K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Starting torque - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe following is the specifications for the ND rating. 50 % (with a motor other than MM-GKR or EM-A) 200 % (with MM-GKR or EM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Torque boost\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual torque boost (induction motor only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Acceleration\/deceleration time setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration\/deceleration modes are available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Stall prevention operation level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation current : 0 to 200 % variable, with selectable availability of the function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Torque limit level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTorque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control *10 , PM sensorless vector control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Number of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Specification of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals 2 and 4 : 0 to 10 V\/0 to 5 V\/4 to 20 mA (0 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput using the operation panel. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX E kit is installed).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Start signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Number of input signal (Contact input)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Input terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-speed operation command, Middle-speed operation command, High-speed operation command, Output stop, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed using Pr.178 to Pr.184 (Input terminal function selection).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Operational function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum and minimum frequency settings, Multi-speed operation, Acceleration\/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotati\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Open collector output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Relay output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Output terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter running, Up to frequency, Fault The signal to be output can be changed using Pr.190 to Pr.192 (Output terminal function selection).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Analog output (AM type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V\/12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Protective function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Warning function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm *11 , Electronic thermal relay function pre-alarm, PU stop, Maintenance timer, Parameter write error, Operation panel lock *11 , Password locked *11 , Speed limit indication *11 , Stroke limit war\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C (The rated current must be reduced at a temperature above 50 °C.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 % RH or less (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Storage temperature *12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Altitude\/vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 3000 m *13 , 5.9 m\/s 2 or less at 10 to 55 Hz in X, Y, and Z directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 : Mitsubishi inverter protocol, MODBUS RTU, BACnet MS\/TP Option unit : CC-Link, DeviceNet, PROFIBUS-DPV0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137189433597,"sku":"FR-E840-0380-4-60","price":910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/587788.jpg?v=1742537433","url":"https:\/\/shly-plc.com\/products\/fr-e840-0380-4-60","provider":"Lianyou PLC","version":"1.0","type":"link"}