{"product_id":"delta-dvp16sp11r","title":"Delta DVP16SP11R Digital I\/O Module","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eDelta · Digital I\/O Modules\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eDVP16SP11R\u003c\/b\u003e is a Delta Digital I\/O Module. It is used in packaging machines, conveyor transfer cells, small process skids where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eDigital I\/O points\u003c\/span\u003e\u003cstrong\u003e16\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 61131-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital I\/O points\u003c\/th\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003cth\u003eDigital I\/O points\u003c\/th\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+55 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eProduct type and series follow the official Delta download-centre catalogue entry for this order number which classifies DVP16SP11R as \"Digital I\/O module, 16 DI\/DO\". Source: https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DVP16SP11R. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eDelta Digital I\/O Modules variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eDigital I\/O points\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eSupply voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eDVP16SP11R\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ca href=\"\/products\/delta-dvp16sp11rt\"\u003eDVP16SP11RT\u003c\/a\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ca href=\"\/products\/delta-dvp16spr\"\u003eDVP16SPR\u003c\/a\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ca href=\"\/products\/delta-dvp16sm\"\u003eDVP16SM\u003c\/a\u003e\n\u003ctd\u003e24 V DC (IEC 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe DVP16SP11R is the I\/O element in a Delta control installation. It terminates the field signals listed above and hands them to the controller, so field wiring and protective devices are sized to the ratings stated in the manufacturer documentation, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in packaging machines, conveyor transfer cells, small process skids, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Delta DVP16SP11R\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDelta DVP16SP11R\u003c\/strong\u003e — PLC \/ CPU module used as the device-level control core in an automation panel, handling logic, timing and communication tasks. The figures below are taken from the specification table on this page for catalog number DVP16SP11R; verify the catalog number against your bill of materials before requesting a quotation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0...+55 °C (IEC 60068-2-1)\u003c\/strong\u003e — Match it to the existing panel and upstream protection.\u003c\/li\u003e\n\u003cli\u003eCertifications: \u003cstrong\u003eCE, UL, cULus\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eTotal I\/O: \u003cstrong\u003e16\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about DVP16SP11R\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich official Delta document defines DVP16SP11R?\u003c\/p\u003e\n\u003cp\u003eThe official Delta download-centre catalogue entry for this order number classifies DVP16SP11R as \"Digital I\/O module, 16 DI\/DO\". The document and its official catalogue record are publicly retrievable at https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DVP16SP11R. Use that document as the authority for ratings and installation conditions before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat does the official Delta catalogue state about the point configuration of DVP16SP11R?\u003c\/p\u003e\n\u003cp\u003eThe official Delta download-centre record for DVP16SP11R describes this order number as \"Digital I\/O module, 16 DI\/DO\", so the specification table lists Digital I\/O points = 16. Source: https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DVP16SP11R\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering DVP16SP11R, which operating temperature entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe operating temperature entry quoted above is 0...+55 °C (IEC 60068-2-1). Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the supply voltage data for DVP16SP11R?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Delta DVP16SP11R as 24 V DC (IEC 61131-2). Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for DVP16SP11R?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number DVP16SP11R, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DVP16SP11R.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the DVP16SP11R replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number DVP16SP11R and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\u003c\/div\u003e","brand":"Delta","offers":[{"title":"New","offer_id":46136926273789,"sku":"DVP16SP11R","price":107.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/DVP16SP11R.jpg?v=1742528758","url":"https:\/\/shly-plc.com\/products\/delta-dvp16sp11r","provider":"SHLY-PLC","version":"1.0","type":"link"}