{"product_id":"delta-drs-24v30w1nz","title":"Delta DRS-24V30W1NZ VFD Drive","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eDelta · Delta VFD AC drive\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eDRS-24V30W1NZ\u003c\/b\u003e is a Delta VFD Drive. It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eRated operational voltage\u003c\/span\u003e\u003cstrong\u003e1-phase 200-240 V \/ 3-phase 380-480 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOverload capacity\u003c\/span\u003e\u003cstrong\u003e150% for 60 s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFrequency\u003c\/span\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd\u003e1-phase 200-240 V \/ 3-phase 380-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e1-phase 200...240 V \/ 3-phase 380...480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003ctd\u003eV\/f, sensorless vector (IEC 61800-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload capacity\u003c\/th\u003e\n\u003ctd\u003e150% for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+40 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eProduct type and series follow the official Delta download-centre catalogue search for this model which lists DRS-24V30W1NZ under the Delta product line; the product type published for this catalog number is \"VFD Drive\". Source: https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DRS-24V30W1NZ. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eDelta Delta VFD AC drive variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eOverload capacity\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eRated operational voltage\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eDRS-24V30W1NZ\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e150% for 60 s\u003c\/td\u003e\n\u003ctd\u003e1-phase 200-240 V \/ 3-phase 380-480 V\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ca href=\"\/products\/delta-drs-24v50w1nz-vfd-drive\"\u003eDRS-24V50W1NZ\u003c\/a\u003e\n\u003ctd\u003e1-phase 200-240 V \/ 3-phase 380-480 V\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/delta-dtc2000c-temperature-controller\"\u003eDTC2000C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/delta-dtc2000l-temperature-controller\"\u003eDTC2000L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe DRS-24V30W1NZ is the drive element in a Delta motor installation. It supplies the motor with controlled power and carries the output frequency and overload behaviour, so the motor and the supply conductor are sized to the ratings stated in the manufacturer documentation, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Delta DRS-24V30W1NZ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDelta DRS-24V30W1NZ\u003c\/strong\u003e — Variable frequency drive for motor speed and torque control in pumps, fans, conveyors and general industrial machinery. The figures below are taken from the specification table on this page for catalog number DRS-24V30W1NZ; always cross-check the catalog number and hardware revision on the nameplate before placing an order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure rating: \u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e — Record it with the other nameplate data when sourcing a replacement.\u003c\/li\u003e\n\u003cli\u003eSupply voltage: \u003cstrong\u003e1-phase 200...240 V \/ 3-phase 380...480 V AC\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eOverload capacity: \u003cstrong\u003e150% for 60 s\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003cli\u003eFrequency: \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about DRS-24V30W1NZ\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich official Delta document defines DRS-24V30W1NZ?\u003c\/p\u003e\n\u003cp\u003eThe official Delta download-centre catalogue search for this model lists DRS-24V30W1NZ under the Delta product line, and the product type published for this catalog number is \"VFD Drive\". The document and its official catalogue record are publicly retrievable at https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DRS-24V30W1NZ. Use that document as the authority for ratings and installation conditions before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eFor DRS-24V30W1NZ, what does the specification table state about enclosure rating?\u003c\/p\u003e\n\u003cp\u003eThe specification table lists enclosure rating = IP20 (IEC 60529) for Delta DRS-24V30W1NZ. Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under supply voltage for catalog number DRS-24V30W1NZ?\u003c\/p\u003e\n\u003cp\u003eFor DRS-24V30W1NZ, supply voltage is given as 1-phase 200...240 V \/ 3-phase 380...480 V AC. Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering DRS-24V30W1NZ, which overload capacity entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe overload capacity entry quoted above is 150% for 60 s. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the DRS-24V30W1NZ replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number DRS-24V30W1NZ and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for DRS-24V30W1NZ?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number DRS-24V30W1NZ, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DRS-24V30W1NZ.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\u003c\/div\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":71124923908349,"sku":"DRS-24V30W1NZ","price":152.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/new_delta_stock_e461fe4b-d533-414e-9996-9a1c843ef7dc.png?v=1786637300","url":"https:\/\/shly-plc.com\/products\/delta-drs-24v30w1nz","provider":"SHLY-PLC","version":"1.0","type":"link"}