{"product_id":"delta-dop-b10s411","title":"Delta DOP-B10S411 HMI Panel","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eDelta · DOP-HMI 2D\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eDOP-B10S411\u003c\/b\u003e is a Delta HMI Panel. It is used in machine operator panels, control cabinets, local HMI stations where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003cstrong\u003e24 V DC (IEC 60950-1)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP65 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan\u003eMounting\u003c\/span\u003e\u003cstrong\u003ePanel \/ DIN rail\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel \/ DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP65 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTouch type\u003c\/th\u003e\n\u003ctd\u003eresistive or projective capacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0...+50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eProduct type and series follow the official Delta download-centre catalogue search for this model which lists DOP-B10S411 under the Delta product line; the product type published for this catalog number is \"HMI Panel\". Source: https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DOP-B10S411. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eDelta DOP-HMI 2D variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eSupply voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eDOP-B10S411\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/delta-dop-b10s615-hmi-panel\"\u003eDOP-B10S615\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/delta-dop-b10e515-hmi-panel\"\u003eDOP-B10E515\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/delta-dop-b10e615-hmi-panel\"\u003eDOP-B10E615\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (IEC 60950-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eBefore selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe DOP-B10S411 is the operator-panel element in a Delta control installation. It shows the machine state to the operator and returns the operator entries to the controller, so it is installed and commissioned against the controller documentation, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in machine operator panels, control cabinets, local HMI stations, where the unit is matched to the original catalog number and the enclosure provides Panel \/ DIN rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Delta DOP-B10S411\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDelta DOP-B10S411\u003c\/strong\u003e — Operator panel for visualisation, parameter setting and alarm handling on a control cabinet door or console. The figures below are taken from the specification table on this page for catalog number DOP-B10S411; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTouch type: \u003cstrong\u003eresistive or projective capacitive\u003c\/strong\u003e — Confirm the revision of the installed unit before a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eMounting: \u003cstrong\u003ePanel \/ DIN rail\u003c\/strong\u003e — Use it as the reference when cross-checking a current-production equivalent.\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e0...+50 °C\u003c\/strong\u003e — Verify it in the project documentation before confirming the order.\u003c\/li\u003e\n\u003cli\u003eSupply voltage: \u003cstrong\u003e24 V DC (IEC 60950-1)\u003c\/strong\u003e — Check this value against the nameplate of the installed unit before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a discontinued unit, match function and electrical ratings rather than the label alone.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about DOP-B10S411\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich official Delta document defines DOP-B10S411?\u003c\/p\u003e\n\u003cp\u003eThe official Delta download-centre catalogue search for this model lists DOP-B10S411 under the Delta product line, and the product type published for this catalog number is \"HMI Panel\". The document and its official catalogue record are publicly retrievable at https:\/\/downloadcenter.deltaww.com\/en-US\/DownloadCenter?q=DOP-B10S411. Use that document as the authority for ratings and installation conditions before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich value is published under mounting for catalog number DOP-B10S411?\u003c\/p\u003e\n\u003cp\u003eFor DOP-B10S411, mounting is given as Panel \/ DIN rail. Confirm this figure against the unit currently in the panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eBefore ordering DOP-B10S411, which enclosure rating entry should be checked?\u003c\/p\u003e\n\u003cp\u003eThe enclosure rating entry quoted above is IP65 (IEC 60529). Use the value as the reference when sourcing a current-production equivalent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhere can I find the touch type data for DOP-B10S411?\u003c\/p\u003e\n\u003cp\u003eIt is listed in the specification table for Delta DOP-B10S411 as resistive or projective capacitive. Check the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eCan the DOP-B10S411 replace the unit currently installed in my panel?\u003c\/p\u003e\n\u003cp\u003eCompare catalog number DOP-B10S411 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat should I include in an enquiry for DOP-B10S411?\u003c\/p\u003e\n\u003cp\u003eSend the full catalog number DOP-B10S411, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DOP-B10S411.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\u003c\/div\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":71124950253821,"sku":"DOP-B10S411","price":1108.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/new_delta_stock_1f67760f-c231-4328-9e18-99cc7d558ddf.png?v=1786637018","url":"https:\/\/shly-plc.com\/products\/delta-dop-b10s411","provider":"SHLY-PLC","version":"1.0","type":"link"}