{"product_id":"controllogix-devicenet-comms-module","title":"Allen-Bradley 1756-DNB - ControlLogix DeviceNet Comms Module","description":"\u003cp\u003e\u003cstrong\u003eControlLogix DeviceNet Comms Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eDeviceNet Bridge\/Scanner Module\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication rate:\u003c\/strong\u003e 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 400mA @ 5.1V DC, 0mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet connector torque:\u003c\/strong\u003e 0.56 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet current draw:\u003c\/strong\u003e 60mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet port:\u003c\/strong\u003e 1 DeviceNet open-style 5- or 10-pin linear plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet power:\u003c\/strong\u003e To comply with the CE low voltage directive (LVD), the DeviceNet network must be powered from a source compliant with the safety extra low voltage (SELV) or protected extra low voltage (PELV). To comply with UL restrictions, the DeviceNet network must be\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet voltage range:\u003c\/strong\u003e 11...25V DC CL 2\/SELV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e ¡À3kV @ 5kHz on DeviceNet ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e CISPR 11: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type rating:\u003c\/strong\u003e None (open-style)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIO link master:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 50V (continuous), basic insulation type, DeviceNet network to backplane, Type tested at 853V AC @ 60s, No isolation between USB and backplane,\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule location:\u003c\/strong\u003e Chassis based, any slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of nodes, max:\u003c\/strong\u003e 64 nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e 3.5 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e 10 V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V\/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V\/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard Bluetooth:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard GPRS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard GSM:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard UMTS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard Wi-Fi 802.11:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 G, Non operating: 50 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot width:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for ASI:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for AS-Interface Safety at Work:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for CAN:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Data-Highway:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for DeviceNet:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for DeviceNet Safety:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for EtherNet\/IP:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Foundation Fieldbus:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for INTERBUS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for INTERBUS-Safety:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for KNX:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for LON:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Modbus:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for other bus systems:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFIBUS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFINET CBA:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFINET IO:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFIsafe:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SafetyBUS p:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SERCOS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SUCONET:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for TCP\/IP:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e ¡À2 kV line-earth (CM) on ControlNet ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal dissipation:\u003c\/strong\u003e 11.9 btu\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring category:\u003c\/strong\u003e 1 - On DeviceNet ports, 3 - On USB ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith optical interface:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith potential separation:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e E\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46335265308925,"sku":"1756-DNB","price":155.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1756-DNB_1000x1000_c7026d13-5b99-4441-8d06-71354d231815.jpg?v=1785381536","url":"https:\/\/shly-plc.com\/products\/controllogix-devicenet-comms-module","provider":"Lianyou PLC","version":"1.0","type":"link"}