{"product_id":"controllogix-8-pt-a-o-i-or-v-hart-module","title":"Allen-Bradley 1756-OF8H - ControlLogix 8 Pt A\/O I or V HART Module","description":"\u003cp\u003e\u003cstrong\u003eControlLogix 8 Pt A\/O I or V HART Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eAnalog Output HART - Current\/Voltage 8 Pts (20 Pin)\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Module Health, In Calibration,Mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e None between channels (Single,Ended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e +\/- 10.4V, 0-20 mA, 4-20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Supports HART Protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue inputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue outputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrated accuracy:\u003c\/strong\u003e Voltage: Better than 0.1% of range @ 25 ¡ãC (77 ¡ãF) with HART disabled, Current: Better than 0.15% of range @ 25 ¡ãC (77 ¡ãF) with HART disabled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData format:\u003c\/strong\u003e Integer mode (left justified, 2 s complement) IEEE 32-bit floating point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e ¡À2kV @ 5kHz on signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e IEC 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type rating:\u003c\/strong\u003e None (open-style)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGain drift with temperature:\u003c\/strong\u003e Voltage: 20 ppm\/¡ãC, Current: 35 ppm\/¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput conversion method:\u003c\/strong\u003e Successive approximation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, current:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistance thermometer:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistor:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal, configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, thermocouple:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, voltage:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 50V (continuous), basic insulation type, output channels to backplane, No isolation between individual output channels type tested at 1500V AC @ 60s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad reactance:\u003c\/strong\u003e Voltage: 1 ¦ÌF, Current: 10 ¦ÌH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule error:\u003c\/strong\u003e Voltage: 0.15% of range, Current: 0.3% of range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule HART scan time:\u003c\/strong\u003e Analog: 12 ms, minimum, floating point, HART: typically 1 s per HART channel enabled. Estimate 10 s if all 8 channels have HART enabled, Pass through messages, handheld communicators, sary masters, communication errors, or configuration changes can s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule keying:\u003c\/strong\u003e Electronic, software configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonoperating temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American temperature code:\u003c\/strong\u003e T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffset drift:\u003c\/strong\u003e 100 ¦ÌV\/¡ãC, 200 nA\/¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen circuit detection time:\u003c\/strong\u003e Current output only (output must be set to \u0026lt;0.1 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 ¡ãC \u003cta\u003e\u003cli\u003e\n\u003cstrong\u003eOutput conversion method:\u003c\/strong\u003e R-Ladder DAC, monotonicity with no missing codes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, current:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput range:\u003c\/strong\u003e -10¡­10V, 0¡­20 mA, 4¡­20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e Eight voltage or current, one HART modem per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, voltage:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage protection:\u003c\/strong\u003e ¡À24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e 4.92 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e 10 V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V\/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V\/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 15...16 bit for all ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTB keying:\u003c\/strong\u003e User-defined mechanical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettling time:\u003c\/strong\u003e Current (no HART): \u0026lt;23 ms to 95% with resistive loads, current (with HART): \u0026lt;37 ms to 95% with resistive loads, voltage: \u0026lt;8.5 ms to 95% with resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 G, Non operating: 50 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot width:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e ¡À2kV line-earth (CM) on shielded ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal block torque specifications:\u003c\/strong\u003e 1756-TBNH: 1.36 Nm (12 in-lb.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal dissipation:\u003c\/strong\u003e 16.78 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal backplane power:\u003c\/strong\u003e 6.54 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw-\/spring clA connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage and current ratings:\u003c\/strong\u003e Backplane: 5.1V DC @ 230mA, 24V DC @ 230mA, Output voltage: -10...+10.4V, Output current: 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire category:\u003c\/strong\u003e 2 - on signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire size:\u003c\/strong\u003e 1756-TBNH: Single wire connection: 0.33...2.1 mm2 (22...14 AWG) solid or stranded copper wire, rated at 105 ¡ãC (221 ¡ãF) or greater, 1.2 mm (3\/64 in.) insulation maximum, 1756-TBNH: Double wire connection: 0.33...1.3 mm2 (22...16 AWG) solid or stranded cop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire type:\u003c\/strong\u003e Copper\u003c\/li\u003e\u003c\/ta\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46216458699005,"sku":"1756-OF8H","price":516.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1756-OF8HK_6cd59abe-6d14-4ca8-b026-442e5ebfcd81.jpg?v=1785380781","url":"https:\/\/shly-plc.com\/products\/controllogix-8-pt-a-o-i-or-v-hart-module","provider":"Lianyou PLC","version":"1.0","type":"link"}