{"product_id":"controllogix-8-pt-a-i-hart-isolated","title":"Allen-Bradley 1756-IF8IH - ControlLogix 8 Pt A\/I HART Isolated","description":"\u003cp\u003e\u003cstrong\u003eControlLogix 8 Pt A\/I HART Isolated\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIsolated Analog Input Module - 8-Channel HART\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Module Health, In Calibration,Mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 0-20mA, 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250V (continuous), reinforced,insulation type, inputs to,backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Supports HART Protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue inputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue outputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrated accuracy:\u003c\/strong\u003e 0.15...1.5% of full scale, filter dependent@ 25 ¡ãC with HART disabled, 1.5% of full scale with 250 Hz filter @ 25 ¡ãC with HART enabled, 0.5% of full scale with 100 Hz filter @ 25 ¡ãC with HART enabled, 0.2% of full scale with 50 Hz or 60 Hz filter @ 25 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode noise rejection:\u003c\/strong\u003e \u0026gt;90 dB @ 50\/60 Hz (10 Hz, 15 Hz or 20 Hz filters only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData format:\u003c\/strong\u003e 32-bit floating point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e ¡À2kV @ 5kHz on signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e IEC 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type rating:\u003c\/strong\u003e None (open-style)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGain drift with temperature:\u003c\/strong\u003e 20 ppm\/¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput conversion method:\u003c\/strong\u003e Sigma-Delta ADC (24-bit converter)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, current:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 250 ? ¡À5 ?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput offset drift with temperature:\u003c\/strong\u003e \u0026lt;=300 ¦ÌA\/¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput overvoltage protection:\u003c\/strong\u003e 28.8V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput range:\u003c\/strong\u003e 0...20 mA (0...20.58 mA), 4...20 mA (3.42...20.58 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistance thermometer:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistor:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e Eight current inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal, configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, thermocouple:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, voltage:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e 400mA @ 5V, 450mA @ 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 250V (continuous), Reinforced insulation type, inputs to backplane, Basic insulation type, input to input, and inputs to ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule error over full temperature range:\u003c\/strong\u003e 0.3% of range (all filters) with HART disabled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule keying:\u003c\/strong\u003e Electronic, software configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule scan time:\u003c\/strong\u003e 18...488 ms (filter dependent) for all channels - analog, minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonoperating temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal mode noise rejection:\u003c\/strong\u003e \u0026gt;90 dB @ 50 Hz and 60 Hz with 10 Hz filter, \u0026gt;74 dB @ 50 Hz and 60 Hz with 15 Hz filter, \u0026gt;33 dB @ 50 Hz and \u0026gt;90 dB @ 60 Hz with 20 Hz filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American temperature code:\u003c\/strong\u003e T5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen circuit detection time:\u003c\/strong\u003e 5 s (4...20 mA range only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 ¡ãC \u003cta\u003e\u003cli\u003e\n\u003cstrong\u003eOutput, current:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, voltage:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation within module:\u003c\/strong\u003e 4 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e 10 V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V\/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V\/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 to 21 bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTB keying:\u003c\/strong\u003e User-defined mechanical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 G, Non operating: 50 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot width:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e ¡À2 kV line-earth (CM) on shielded signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal block torque specifications:\u003c\/strong\u003e 1756-TBCH: 0.5 Nm (4.4 in-lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw-\/spring clA connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical module HART dynamic variables update time for all channels:\u003c\/strong\u003e 1 s typical if all channels are HART enabled Pass through messages, handheld communications, sary masters, communication errors, or configuration changes can significantly increase the update time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage and current ratings:\u003c\/strong\u003e Backplane: 210mA @ 5.1V DC, 110mA @ 24V DC, Input voltage range: 5...30V DC, Input current range: 0...20mA @ 4...20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire category:\u003c\/strong\u003e 2 - on signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire size:\u003c\/strong\u003e Single wire connection (1756-TBCH): 0.33...2.1 mm2 (22...14 AWG) solid or stranded shielded copper wire, rated at 105 ¡ãC (221 ¡ãF) or greater, 1.2 mm (3\/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm2 (22...14 AWG) solid or\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire type:\u003c\/strong\u003e Copper\u003c\/li\u003e\u003c\/ta\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46345214460157,"sku":"1756-IF8IH","price":1497.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1756-IF8IH_1000x1000_77c99c5f-8ffd-4561-8f53-93cf6a3bb243.jpg?v=1785381266","url":"https:\/\/shly-plc.com\/products\/controllogix-8-pt-a-i-hart-isolated","provider":"Lianyou PLC","version":"1.0","type":"link"}