{"product_id":"allen-bradley-2080-of2","title":"Allen-Bradley 2080-OF2 Micro800 2 Point Analog Output Plug-In","description":"\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eAllen-Bradley · 2080-OF2\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e2080-OF2\u003c\/b\u003e is an Allen-Bradley 2080-OF2 — Micro800 2 Point Analog Output Plug-In. Official specification values published for this catalog number: Operating temperature -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)；Mounting torque 0.2 nm；Shock IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003cstrong\u003e-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting torque\u003c\/span\u003e\u003cstrong\u003e0.2 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eShock\u003c\/span\u003e\u003cstrong\u003eIEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTerminal screw torque\u003c\/span\u003e\u003cstrong\u003e0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad range on voltage output\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 1k Ω @ 10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistive load on current output\u003c\/th\u003e\n\u003ctd\u003e0...500 Ω (includes wire resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue inputs configurable\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue outputs configurable\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel to channel isolation\u003c\/th\u003e\n\u003ctd\u003eNon-isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent load on voltage output, max\u003c\/th\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\/A Conversion rate (all channels), max\u003c\/th\u003e\n\u003ctd\u003e2.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput group to bus isolation\u003c\/th\u003e\n\u003ctd\u003eNon-isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput signal, configurable\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, current\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, resistance thermometer\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, resistor\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, thermocouple\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, voltage\u003c\/th\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analogue outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput count range\u003c\/th\u003e\n\u003ctd\u003e0 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput error\u003c\/th\u003e\n\u003ctd\u003eVoltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput overvoltage protection\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput signal configurable\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput, current\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput, voltage\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall accuracy\u003c\/th\u003e\n\u003ctd\u003eVoltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of the analogue outputs\u003c\/th\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of electric connection\u003c\/th\u003e\n\u003ctd\u003eScrew connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage ranges\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire size\u003c\/th\u003e\n\u003ctd\u003eSolid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Isolation\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;60mA @ 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting torque\u003c\/th\u003e\n\u003ctd\u003e0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal screw torque\u003c\/th\u003e\n\u003ctd\u003e0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock\u003c\/th\u003e\n\u003ctd\u003eIEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003eIEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSIL according to IEC 61508\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Rating\u003c\/th\u003e\n\u003ctd\u003e-20…65 °C (-4…149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConducted RF immunity\u003c\/th\u003e\n\u003ctd\u003eIEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEFT\/B immunity\u003c\/th\u003e\n\u003ctd\u003eIEC 61000-4-4: ±2kV @ 5kHz on shielded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eESD immunity\u003c\/th\u003e\n\u003ctd\u003eIEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eCISPR 11 (IEC 61000-6-4): Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNonoperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNorth American temperature code\u003c\/th\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude\u003c\/th\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRadiated RF immunity\u003c\/th\u003e\n\u003ctd\u003eIEC 61000-4-3: 10V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V\/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V\/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003eIEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge transient immunity\u003c\/th\u003e\n\u003ctd\u003eIEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurrounding air temperature, max\u003c\/th\u003e\n\u003ctd\u003e65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNon-linearity\u003c\/th\u003e\n\u003ctd\u003e±0.1% @ in % full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitive load, max\u003c\/th\u003e\n\u003ctd\u003e0.1 µF @ voltage outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInductive load, max\u003c\/th\u003e\n\u003ctd\u003e0.01 mH @ current outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpen and short-circuit protection\u003c\/th\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum shielded cable length\u003c\/th\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStep response to 63%\u003c\/th\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Status Indication\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eNot published by the manufacturer — 待原厂规格书核定\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O and communication\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues above are copied verbatim from the manufacturer product page (\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.2080-of2.html\"\u003ehttps:\/\/www.rockwellautomation.com\/en-us\/products\/details.2080-of2.html\u003c\/a\u003e) or the manufacturer technical data publication. Fields listed with the value 待原厂规格书核定 are not published by the manufacturer for this catalog number: the field name is kept, no value is estimated, and the original manufacturer data sheet is required before use.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Allen-Bradley 2080-OF2\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting torque: \u003cstrong\u003e0.2 nm\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eShock: \u003cstrong\u003eIEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eTerminal screw torque: \u003cstrong\u003e0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eVibration: \u003cstrong\u003eIEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eLoad range on voltage output: \u003cstrong\u003e\u0026gt; 1k Ω @ 10V DC\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\u003ch3\u003eCommon questions about 2080-OF2\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-OF2?\u003c\/p\u003e\n\u003cp\u003eFor 2080-OF2 The manufacturer product page publishes mounting torque = 0.2 nm. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-OF2?\u003c\/p\u003e\n\u003cp\u003eFor 2080-OF2 The manufacturer product page publishes shock = IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-OF2?\u003c\/p\u003e\n\u003cp\u003eFor 2080-OF2 The manufacturer product page publishes terminal screw torque = 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver). Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-OF2?\u003c\/p\u003e\n\u003cp\u003eFor 2080-OF2 The manufacturer product page publishes vibration = IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 2080-OF2 before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 2080-OF2 and the specification values above against the nameplate of the installed unit, and confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46279546306813,"sku":"2080-OF2","price":204.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/2080-OF2.jpg?v=1793772259","url":"https:\/\/shly-plc.com\/products\/allen-bradley-2080-of2","provider":"SHLY-PLC","version":"1.0","type":"link"}