{"product_id":"allen-bradley-2080-l50e-48qbb","title":"Allen-Bradley 2080-L50E-48QBB Micro850 48 I\/O ENet\/IP Controller","description":"\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eAllen-Bradley · 2080-L50E\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e2080-L50E-48QBB\u003c\/b\u003e is an Allen-Bradley 2080-L50E-48QBB — Micro850 48 I\/O ENet\/IP Controller. Official specification values published for this catalog number: Turn-on time, max 0.1 ms；Turn-off time, max 1.0 ms；Surge current, per point (1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F).\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eTurn-on time, max\u003c\/span\u003e\u003cstrong\u003e0.1 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTurn-off time, max\u003c\/span\u003e\u003cstrong\u003e1.0 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSurge current, per point\u003c\/span\u003e\u003cstrong\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eResponse time, max\u003c\/span\u003e\u003cstrong\u003e10 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge current, per point\u003c\/th\u003e\n\u003ctd\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage, min\u003c\/th\u003e\n\u003ctd\u003e10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage, max\u003c\/th\u003e\n\u003ctd\u003e26.4V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOn-state voltage drop\u003c\/th\u003e\n\u003ctd\u003e1V @ max load current \/ 2.5V @ max surge current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad current, min\u003c\/th\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad current, max\u003c\/th\u003e\n\u003ctd\u003e1.0 A @ 30 °C (86 °F) \/ 0.3 A @ 65 °C (149 °F) (standard operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage category\u003c\/th\u003e\n\u003ctd\u003e24V sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOn-state voltage, nom\u003c\/th\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOn-state voltage range\u003c\/th\u003e\n\u003ctd\u003e16.8…26.4V DC @ 65 °C (149 °F) \/ 16.8…30.0V DC @ 30 °C (86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOn-state current, min\u003c\/th\u003e\n\u003ctd\u003e5.0 mA @ 16.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOn-state current, max\u003c\/th\u003e\n\u003ctd\u003e12.0 mA @ 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOff-state voltage, min\u003c\/th\u003e\n\u003ctd\u003e4V AC @ 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOff-state voltage, max\u003c\/th\u003e\n\u003ctd\u003e5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput group to backplane isolation\u003c\/th\u003e\n\u003ctd\u003eVerified by one of the following dielectric tests: \/ • 720V DC for 2 s \/ • 50V DC working voltage (IEC Class 2 reinforced insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIEC input compatibility\u003c\/th\u003e\n\u003ctd\u003eType 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply voltage range\u003c\/th\u003e\n\u003ctd\u003e21.4…26.4V DC Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption, max\u003c\/th\u003e\n\u003ctd\u003e11 W – Without plug-in modules and expansion I\/O modules \/ 33 W – With plug-in modules and expansion I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput circuit type\u003c\/th\u003e\n\u003ctd\u003e24V DC source \/ (standard and high-speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure type rating\u003c\/th\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal screw torque\u003c\/th\u003e\n\u003ctd\u003e0.4…0.5 N•m (3.5…4.4 lb•in) using a 0.6 x 3.5 mm screwdriver. \/ Use a handheld screwdriver to hold down the screws at the side.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight, approx.\u003c\/th\u003e\n\u003ctd\u003e0.725 kg (1.60 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (HxWxD)\u003c\/th\u003e\n\u003ctd\u003e90 x 238 x 80 mm (3.54 x 9.37 x 3.15 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTurn-on time, max\u003c\/th\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTurn-off time, max\u003c\/th\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time, max\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency, rate\u003c\/th\u003e\n\u003ctd\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating frequency, nom\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNorth American temp code\u003c\/th\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation-stripping length\u003c\/th\u003e\n\u003ctd\u003e7 mm (0.28 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of I\/O\u003c\/th\u003e\n\u003ctd\u003e48 (28 inputs, 20 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eNot published by the manufacturer — 待原厂规格书核定\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues above are copied verbatim from the manufacturer product page (\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.2080-l50e-48qbb.html\"\u003ehttps:\/\/www.rockwellautomation.com\/en-us\/products\/details.2080-l50e-48qbb.html\u003c\/a\u003e) or the manufacturer technical data publication. Fields listed with the value 待原厂规格书核定 are not published by the manufacturer for this catalog number: the field name is kept, no value is estimated, and the original manufacturer data sheet is required before use.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eAllen-Bradley 2080-L50E variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:22%\"\u003eTurn-on time, max\u003c\/th\u003e\n\u003cth style=\"width:22%\"\u003eTurn-off time, max\u003c\/th\u003e\n\u003cth style=\"width:22%\"\u003eSurge current, per point\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2080-L50E-24QBB\u003c\/td\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003ctd\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e2080-L50E-48QBB\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003ctd\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2080-L50E-48QWB\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSee Relay Contacts Ratings - Micro850 Controllers on page 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2080-L50E-48AWB\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSee Relay Contacts Ratings - Micro850 Controllers on page 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2080-L50E-24AWB\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSee Relay Contacts Ratings - Micro850 Controllers on page 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2080-L50E-48QVB\u003c\/td\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003ctd\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSelection notes for Allen-Bradley 2080-L50E-48QBB\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn-on time, max: \u003cstrong\u003e0.1 ms\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eTurn-off time, max: \u003cstrong\u003e1.0 ms\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eSurge current, per point: \u003cstrong\u003e(1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F)\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eResponse time, max: \u003cstrong\u003e10 ms\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003eOutput voltage, min: \u003cstrong\u003e10V DC\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\u003ch3\u003eCommon questions about 2080-L50E-48QBB\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-L50E-48QBB?\u003c\/p\u003e\n\u003cp\u003eFor 2080-L50E-48QBB The official manufacturer data sheet publishes turn-on time, max = 0.1 ms. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-L50E-48QBB?\u003c\/p\u003e\n\u003cp\u003eFor 2080-L50E-48QBB The official manufacturer data sheet publishes turn-off time, max = 1.0 ms. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-L50E-48QBB?\u003c\/p\u003e\n\u003cp\u003eFor 2080-L50E-48QBB The official manufacturer data sheet publishes surge current, per point = (1) \/ 4.0 A every 1 s @ 30 °C (86 °F); every 2 s @ 65 °C (149 °F). Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 2080-L50E-48QBB?\u003c\/p\u003e\n\u003cp\u003eFor 2080-L50E-48QBB The official manufacturer data sheet publishes response time, max = 10 ms. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 2080-L50E-48QBB before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 2080-L50E-48QBB and the specification values above against the nameplate of the installed unit, and confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46223592620285,"sku":"2080-L50E-48QBB","price":536.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/2080-L50E-48QBB.webp?v=1793771290","url":"https:\/\/shly-plc.com\/products\/allen-bradley-2080-l50e-48qbb","provider":"SHLY-PLC","version":"1.0","type":"link"}