{"product_id":"allen-bradley-1769-if16vk","title":"Allen-Bradley 1769-IF16VK CompactLogix 16 Pt A\/I Voltage Module","description":"\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eAllen-Bradley · 1769-IF16VK\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e1769-IF16VK\u003c\/b\u003e is an Allen-Bradley 1769-IF16VK — CompactLogix 16 Pt A\/I Voltage Module. Official specification values published for this catalog number: Power supply 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4；c-UL C-UL certified (under CSA C22.2 No. 142) \/ UL 508 listed \/ Class I, Division 2 Group A,B,C,D Hazardous Locations (UL 1604, C-UL under CSA C22.2 No. 213)；voltage(3) \/ Rated working 30V AC\/30V DC.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003ePower supply\u003c\/span\u003e\u003cstrong\u003e1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ec-UL\u003c\/span\u003e\u003cstrong\u003eC-UL certified (under CSA C22.2 No. 142) \/ UL 508 listed \/ Class I, Division 2 Group A,B,C,D Hazardous Locations (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003evoltage(3) \/ Rated working\u003c\/span\u003e\u003cstrong\u003e30V AC\/30V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003erange(4) \/ Common mode voltage\u003c\/span\u003e\u003cstrong\u003e±10V DC max per channel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003evoltage(3) \/ Rated working\u003c\/th\u003e\n\u003ctd\u003e30V AC\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003erange(4) \/ Common mode voltage\u003c\/th\u003e\n\u003ctd\u003e±10V DC max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003erange(1) \/ Full scale\u003c\/th\u003e\n\u003ctd\u003e±10.5V \/ -0.5…10.5V \/ -0.5…5.25V \/ 0.5…5.25V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emax(7) \/ Overload at input terminals,\u003c\/th\u003e\n\u003ctd\u003e±30 mA continuous, ±7.6V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy drift with temperature\u003c\/th\u003e\n\u003ctd\u003e±0.03% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy(5)\u003c\/th\u003e\n\u003ctd\u003e±0.35% full scale @ 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent draw @ 24V\u003c\/th\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent draw @ 5.1V\u003c\/th\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput impedance\u003c\/th\u003e\n\u003ctd\u003eM \/ \u0026gt; 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput range\u003c\/th\u003e\n\u003ctd\u003e±10V \/ 0…10V \/ 0…5V \/ 1…5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput words\u003c\/th\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs\u003c\/th\u003e\n\u003ctd\u003e16 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation voltage\u003c\/th\u003e\n\u003ctd\u003e500V AC or 710V DC for 1 minute (qualification test), group to bus \/ 30V AC\/30V DC working voltage (IEC Class 2 reinforced insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput words\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply distance rating\u003c\/th\u003e\n\u003ctd\u003e8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommon mode voltage range(4)\u003c\/th\u003e\n\u003ctd\u003e±10V DC max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull scale range(1)\u003c\/th\u003e\n\u003ctd\u003e±10.5V ; -0.5…10.5V ; -0.5…5.25V ; 0.5…5.25V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload at input terminals, max(7)\u003c\/th\u003e\n\u003ctd\u003e±30 mA continuous, ±7.6V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated working voltage(3)\u003c\/th\u003e\n\u003ctd\u003e30V AC\/30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution (2)\u003c\/th\u003e\n\u003ctd\u003e16 bits (unipolar) ; 15 bits plus sign (bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (HxWxD), approx\u003c\/th\u003e\n\u003ctd\u003e118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) \/ Height with mounting tabs 138 mm (5.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure type rating\u003c\/th\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRetaining screw torque\u003c\/th\u003e\n\u003ctd\u003e0.46 Nm (4.1 lbin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlot width\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal screw torque\u003c\/th\u003e\n\u003ctd\u003e0.68 Nm (6 lbin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight, approx\u003c\/th\u003e\n\u003ctd\u003e281 g (0.62 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-40…85 °C (-40…185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emust be rated Class 2.\u003c\/th\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003e5 g @ 10…500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operating\u003c\/th\u003e\n\u003ctd\u003e0…60 °C (32…140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, nonoperating\u003c\/th\u003e\n\u003ctd\u003e-40…+85 °C (-40…+185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock, operating\u003c\/th\u003e\n\u003ctd\u003ePanel mount 30 g \/ DIN rail mount 20 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock, nonoperating\u003c\/th\u003e\n\u003ctd\u003ePanel mount 40 g \/ DIN rail mount 30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e5…95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ec-UL\u003c\/th\u003e\n\u003ctd\u003eC-UL certified (under CSA C22.2 No. 142) \/ UL 508 listed \/ Class I, Division 2 Group A,B,C,D Hazardous Locations (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransmitter \/ -\u003c\/th\u003e\n\u003ctd\u003e(22…14 AWG) solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor\/ \/ +\u003c\/th\u003e\n\u003ctd\u003e0.46 N•m (4.1 lb•in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIN+\u003c\/th\u003e\n\u003ctd\u003e500V AC or 710V DC for 1 minute (qualification test), \/ group to bus \/ 30V AC\/30V DC working voltage \/ (IEC Class II reinforced insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCOM\u003c\/th\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA and CE\u003c\/th\u003e\n\u003ctd\u003eUK Statutory Instrument 2016 No. 1091 and European Union 2014\/30\/EU EMC Directive, compliant with: \/ EN 61000-6-2; Industrial Immunity \/ EN 61000-6-4; Industrial Emissions \/ UK Statutory Instrument 2012 No. 3032 and European Union 2011\/65\/EU RoHS, compliant with: \/ EN IEC 63000; Technical documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommon mode rejection\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 60 dB @ 50 and 60 Hz with the 16 Hz filter selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration words\u003c\/th\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConverter type\u003c\/th\u003e\n\u003ctd\u003eSigma Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFilter Frequency\u003c\/th\u003e\n\u003ctd\u003eStep Response \/ Update per Input Point \/ Update per Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat dissipation, max\u003c\/th\u003e\n\u003ctd\u003e2.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule error\u003c\/th\u003e\n\u003ctd\u003e1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule location\u003c\/th\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNonlinearity\u003c\/th\u003e\n\u003ctd\u003e±0.03%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type code\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability(6)\u003c\/th\u003e\n\u003ctd\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacement door\u003c\/th\u003e\n\u003ctd\u003e1769-RD (2 per kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacement door label\u003c\/th\u003e\n\u003ctd\u003e1769-RL2 series B (2 per kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacement terminal block\u003c\/th\u003e\n\u003ctd\u003e1769-RTBN18 (1 per kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVendor ID code\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eNot published by the manufacturer — 待原厂规格书核定\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003e待原厂规格书核定\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues above are copied verbatim from the manufacturer product page (\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.1769-if16vk.html\"\u003ehttps:\/\/www.rockwellautomation.com\/en-us\/products\/details.1769-if16vk.html\u003c\/a\u003e) or the manufacturer technical data publication. Fields listed with the value 待原厂规格书核定 are not published by the manufacturer for this catalog number: the field name is kept, no value is estimated, and the original manufacturer data sheet is required before use.\u003c\/p\u003e\n\u003ch3\u003eSelection notes for Allen-Bradley 1769-IF16VK\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL: \u003cstrong\u003eC-UL certified (under CSA C22.2 No. 142) \/ UL 508 listed \/ Class I, Division 2 Group A,B,C,D Hazardous Locations (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003evoltage(3) \/ Rated working: \u003cstrong\u003e30V AC\/30V DC\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003erange(4) \/ Common mode voltage: \u003cstrong\u003e±10V DC max per channel\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003erange(1) \/ Full scale: \u003cstrong\u003e±10.5V \/ -0.5…10.5V \/ -0.5…5.25V \/ 0.5…5.25V\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003cli\u003emax(7) \/ Overload at input terminals,: \u003cstrong\u003e±30 mA continuous, ±7.6V DC\u003c\/strong\u003e — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable from stock with datasheet, certificates and a quotation on request.\u003c\/p\u003e\n\u003ch3\u003eCommon questions about 1769-IF16VK\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 1769-IF16VK?\u003c\/p\u003e\n\u003cp\u003eFor 1769-IF16VK The official manufacturer data sheet publishes c-ul = C-UL certified (under CSA C22.2 No. 142) \/ UL 508 listed \/ Class I, Division 2 Group A,B,C,D Hazardous Locations (UL 1604, C-UL under CSA C22.2 No. 213). Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 1769-IF16VK?\u003c\/p\u003e\n\u003cp\u003eFor 1769-IF16VK The official manufacturer data sheet publishes voltage(3) \/ rated working = 30V AC\/30V DC. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 1769-IF16VK?\u003c\/p\u003e\n\u003cp\u003eFor 1769-IF16VK The official manufacturer data sheet publishes range(4) \/ common mode voltage = ±10V DC max per channel. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat specification value does the manufacturer publish for 1769-IF16VK?\u003c\/p\u003e\n\u003cp\u003eFor 1769-IF16VK The official manufacturer data sheet publishes range(1) \/ full scale = ±10.5V \/ -0.5…10.5V \/ -0.5…5.25V \/ 0.5…5.25V. Confirm the revision of the installed unit if the catalog number has been superseded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow do I confirm compatibility of 1769-IF16VK before ordering?\u003c\/p\u003e\n\u003cp\u003eMatch the catalog number 1769-IF16VK and the specification values above against the nameplate of the installed unit, and confirm the firmware or hardware revision where a revision-sensitive part is involved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":70974155423997,"sku":"1769-IF16VK","price":662.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1769-IF16VK_ee17d11c-fe23-40b0-801b-fdb527c2bbd0.jpg?v=1792905713","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1769-if16vk","provider":"SHLY-PLC","version":"1.0","type":"link"}