{"product_id":"allen-bradley-1769-aentr","title":"Allen-Bradley 1769-AENTR | Communication \u0026 I\/O Module","description":"\u003cp\u003e\u003cstrong\u003e1769 Ethernet\/IP Adapter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1769 Network Adaptor,Ethernet,69-I\/O,24.0V DC, Dual Port\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 118mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e 2 Ethernet RJ45 Category 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 50V (continuous), basic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 500mA @ 5.2V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 87 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e ¡À3kV @ 5kHz on communications ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e CISPR 11 (IEC 61000-6-4): Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type rating:\u003c\/strong\u003e None (open-style)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP communication rate:\u003c\/strong\u003e 10\/100 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIO link master:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 50V (continuous), basic insulation type, Tested at 710V DC @ 60s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogix communication connections:\u003c\/strong\u003e 128\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule location:\u003c\/strong\u003e DIN rail or panel mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting screw torque:\u003c\/strong\u003e 1.16 Nm (10 in-lb) - use M4 or #8 screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonoperating temperature:\u003c\/strong\u003e -40 to 85 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of HW-interfaces industrial Ethernet:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 2 Ethernet RJ45 Category 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e 10V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V\/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V\/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard Bluetooth:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard GPRS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard GSM:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard UMTS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio standard Wi-Fi 802.11:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 15 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot width:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for ASI:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for AS-Interface Safety at Work:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for CAN:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Data-Highway:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for DeviceNet:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for DeviceNet Safety:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for EtherNet\/IP:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Foundation Fieldbus:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for INTERBUS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for INTERBUS-Safety:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for KNX:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for LON:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for Modbus:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for other bus systems:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFIBUS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFINET CBA:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFINET IO:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for PROFIsafe:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SafetyBUS p:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SERCOS:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for SUCONET:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupporting protocol for TCP\/IP:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e ¡À2 kV line-earth (CM) on communication ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCP\/IP communication connections:\u003c\/strong\u003e 96\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of data transmission:\u003c\/strong\u003e Other\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight, approx:\u003c\/strong\u003e 0.28 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire category:\u003c\/strong\u003e 1 - on communication ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire size:\u003c\/strong\u003e Ethernet connections: RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO\/IEC 24702.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith optical interface:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith potential separation:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47841307197693,"sku":"1769-AENTR","price":492.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1769-AENTR.jpg?v=1785382995","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1769-aentr","provider":"Lianyou PLC","version":"1.0","type":"link"}