{"product_id":"allen-bradley-1762-ir4","title":"Allen-Bradley 1762-IR4 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eMicroLogix 4 Point Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1762 MicroLogix 1200 System, MicroLogix 4 Point Module\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e Progmable Logic Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 87\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Isolation:\u003c\/strong\u003e Isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Status Indication:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Interfaces:\u003c\/strong\u003e resistance thermom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 4 point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e 0¡­55 ¡ãC (32¡­131 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Type:\u003c\/strong\u003e 4 Channel, RTD\/Resistance Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy drift:\u003c\/strong\u003e At 0...55 ¡ãC ¡À0.026 ¡ãC\/¡ãC (0.026 ¡ãF\/¡ãF) for Pt 385, ¡À0.007 ?\/¡ãC (0.012 ?\/¡ãF) for 150 ? range, ¡À0.023 ¡ãC\/¡ãC (0.023 ¡ãF\/¡ãF) for Pt 3916, ¡À0.023 ?\/¡ãC (0.041 ?\/¡ãF) for 500 ? range, ¡À0.012 ¡ãC\/¡ãC (0.012 ¡ãF\/¡ãF) for Ni, ¡À0.043 ?\/¡ãC (0.077 ?\/¡ãF) for 1,000 ? range,\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D converter type:\u003c\/strong\u003e Delta-Sigma\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue inputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue outputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus current draw:\u003c\/strong\u003e 50mA @ 24V DC, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable impedance:\u003c\/strong\u003e Maximum @ 25 ? (operating with \u0026gt;25 ? will reduce accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel diagnostics:\u003c\/strong\u003e Over or under range or open circuit condition by bit reporting for analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to channel isolation:\u003c\/strong\u003e ¡À10V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode rejection:\u003c\/strong\u003e \u0026gt;110 dB at 60 Hz (with 10 or 60 Hz filter)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted immunity:\u003c\/strong\u003e IEC 1000-4-6: 10 V\/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation current source:\u003c\/strong\u003e 0.5 mA and 1.0 mA selectable per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast transient burst:\u003c\/strong\u003e IEC1000-4-4: 2kV @ 5kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous environment class:\u003c\/strong\u003e Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat dissipation:\u003c\/strong\u003e 1.5 total W (the W per point, plus the minimum W, with all points enabled)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output group to system isolation:\u003c\/strong\u003e 30V AC\/30V DC working voltage type test: 500V AC or 707V DC @ 1min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput channel configuration:\u003c\/strong\u003e Via configuration software screen or the user prog (by writing a unique bit pattern into the module¡¯s configuration file)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, current:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e \u0026gt;10 M?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistance thermometer:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistor:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal, configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, thermocouple:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput type:\u003c\/strong\u003e 604 ? Nickel-Iron 518\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, voltage:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule power LED:\u003c\/strong\u003e ON: indicates power is applied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-linearity:\u003c\/strong\u003e ¡À0.05% (in % full scale)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal mode rejection ratio:\u003c\/strong\u003e 70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of analogue inputs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-circuit detection time:\u003c\/strong\u003e 6 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, current:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, voltage:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload at input terminals:\u003c\/strong\u003e Maximum @ ¡À35V DC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply distance rating:\u003c\/strong\u003e 6 (the module may not be more than 6 modules away from the system power supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated and conducted emissions:\u003c\/strong\u003e EN50081-2: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated immunity:\u003c\/strong\u003e IEC 61000-4-3: 10 V\/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended cable:\u003c\/strong\u003e Belden 8761 (shielded)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ¡À0.2 ? for other resistances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Input filter and configuration dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight, approx:\u003c\/strong\u003e 260 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge immunity:\u003c\/strong\u003e IEC1000-4-5: 1kV galvanic gun\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical accuracy:\u003c\/strong\u003e At 25 ¡ã C (77 ¡ãF) ambient with module operating temperature at 25 ¡ãC (77 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical overall accuracy:\u003c\/strong\u003e ¡À0.5 ¡ãC (¡ãF) for Pt 385\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate time:\u003c\/strong\u003e Input filter and configuration dependent (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47841290715389,"sku":"1762-IR4","price":372.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1762-IR4.jpg?v=1785382965","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1762-ir4","provider":"Lianyou PLC","version":"1.0","type":"link"}