{"product_id":"allen-bradley-1762-iq8ow6","title":"Allen-Bradley 1762-IQ8OW6 | Relay \u0026 Timer","description":"\u003cp\u003e\u003cstrong\u003eMicroLogix 14 Point Digital Comb Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1762 MicroLogix 1200 System, 8 Point 24 VDC Sink\/Source Input\/6 Point VAC\/VDC Relay Output Combination Module\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e Progmable Logic Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 87\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003edigital combination modules:\u003c\/strong\u003e 8 Point 24V DC Sink\/Source Input\/6 Point VAC\/VDC Relay Output Combination Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Isolation:\u003c\/strong\u003e Isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Status Indication:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Interfaces:\u003c\/strong\u003e digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 14 point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 6 Point, Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e -20¡­65 ¡ãC (-4¡­149 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus current draw, max:\u003c\/strong\u003e 80mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e IEC 1000-4-6: 10V @ 0.15...80MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital inputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e IEC1000-4-4: 2kV @ 5kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous environment class:\u003c\/strong\u003e Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat dissipation, max:\u003c\/strong\u003e 5.0 W @ 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC input compatibility:\u003c\/strong\u003e Type 1+\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput group to backplane isolation:\u003c\/strong\u003e Verified by one of the following dielectric tests: 1200V AC @ 1s or 1697V DC @ 1s 75V DC working voltage (IEC Class 2 reinforced insulation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current, max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated groups:\u003c\/strong\u003e Group 1: inputs 0...3, Group 2: inputs 4¡­7, Group 3: output 0...5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Impedance:\u003c\/strong\u003e 3 k?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of commons:\u003c\/strong\u003e Input : 2, output : 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of digital inputs:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-state current:\u003c\/strong\u003e 1.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-state leakage current, max:\u003c\/strong\u003e 0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-state voltage, max:\u003c\/strong\u003e 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON-state current, max:\u003c\/strong\u003e 12.0mA @ 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-state current, min:\u003c\/strong\u003e 2.0mA @ 10V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-state current, nom:\u003c\/strong\u003e 8.0mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-state voltage, min:\u003c\/strong\u003e 10V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20 to 65 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 10...30V DC @ 30¡ãC (86 ¡ãF) 10...26.4V DC @ 65¡ãC (149 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply distance rating:\u003c\/strong\u003e 6 (the module may not be more than 6 modules away from the system power supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated and conducted emissions:\u003c\/strong\u003e EN50081-2: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e IEC1000-4-3: 10 V\/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection, outputs available:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal delay:\u003c\/strong\u003e On delay: 10.0 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature, min:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e IEC1000-4-5: 2 kV common mode, 1 kV differential mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime delay at signal exchange:\u003c\/strong\u003e 8 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of voltage (input voltage):\u003c\/strong\u003e DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operating: 10 to 500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis. Relay ops: 1.5G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage category:\u003c\/strong\u003e 24V DC sink\/source\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 280 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 40.4 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47841289928957,"sku":"1762-IQ8OW6","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1762-IQ8OW6.jpg?v=1785382950","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1762-iq8ow6","provider":"Lianyou PLC","version":"1.0","type":"link"}