{"product_id":"allen-bradley-1762-if2of2-industrial-automation-component","title":"Allen-Bradley 1762-IF2OF2 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eMicroLogix 4 Point Analog Comb Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1762 MicroLogix 1200 System, 4 Channel Analog Combo Module\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e Progmable Logic Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 4-20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 87\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Isolation:\u003c\/strong\u003e Isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Ports:\u003c\/strong\u003e 4 Channel Analog Combo Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Status Indication:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Interfaces:\u003c\/strong\u003e analog combination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber Of Channels:\u003c\/strong\u003e 4 point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 2 Point, 0-10V, 4-20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e -20¡­65 ¡ãC (-4¡­149 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D converter type:\u003c\/strong\u003e Successive approximation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog normal operating range:\u003c\/strong\u003e Voltage: 0...10V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue inputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue outputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus current draw, max:\u003c\/strong\u003e 40mA @ 5V DC, 105mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel diagnostics:\u003c\/strong\u003e Over or under range or open circuit condition by bit reporting for analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode rejection:\u003c\/strong\u003e \u0026gt;55 dB at 50 and 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode voltage range:\u003c\/strong\u003e -27 to 27V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted immunity:\u003c\/strong\u003e IEC 1000-4-6: 10V @ 0.15...80MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent input protection:\u003c\/strong\u003e -32 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\/A converter type:\u003c\/strong\u003e Resistor string\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast transient burst:\u003c\/strong\u003e IEC1000-4-4: 2kV @ 5kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull scale analog ranges:\u003c\/strong\u003e Voltage: 0...10.5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale range:\u003c\/strong\u003e 10.5V DC @ 0...10V DC, 21.0mA @ 4...20mA, 20.0mA @ 4...20mA, 4.0mA @ 4...20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous environment class:\u003c\/strong\u003e Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput and output group to system isolation:\u003c\/strong\u003e 30V AC\/30V DC rated working voltage (N.E.C. Class 2 required) (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, current:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e Voltage Terminal: 200 K?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistance thermometer:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, resistor:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal, configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, thermocouple:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput update time:\u003c\/strong\u003e Typical: 2.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput, voltage:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad range on voltage output:\u003c\/strong\u003e \u0026gt;1K?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule power LED:\u003c\/strong\u003e On: indicates power is applied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-linearity:\u003c\/strong\u003e ¡À0.12% (in % full scale)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of inputs:\u003c\/strong\u003e 2 differential (unipolar)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of outputs:\u003c\/strong\u003e 2 single-ended (unipolar)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen and short-circuit protection:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -20 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, current:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput protection:\u003c\/strong\u003e -32 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ripple range:\u003c\/strong\u003e \u0026lt;¡À0.1% @ 0...500Hz (referred to output range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput update time:\u003c\/strong\u003e Typical: 4.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput, voltage:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated and conducted emissions:\u003c\/strong\u003e EN50081-2: Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated immunity:\u003c\/strong\u003e IEC1000-4-3: 10 V\/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAW\/Proportional data:\u003c\/strong\u003e 32,760 @ 0...10V DC, 32,760 @ 4...20 mA, 31,200 @ 4...20 mA, 6240 @ 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactive load, current output:\u003c\/strong\u003e \u0026lt;0.1 mH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactive load, voltage output:\u003c\/strong\u003e \u0026lt;1 ¦ÌF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended cable:\u003c\/strong\u003e Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer¡¯s recommendations.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e -0.12 to 0.12%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistive load on current output:\u003c\/strong\u003e 0...500 ? (includes wire resistance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution of the analogue inputs:\u003c\/strong\u003e 12 bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScaled-for-PID:\u003c\/strong\u003e 16,380 @ 0...10V DC, 16,380 @ 4...20 DC, 15,600 @ 4...20V DC, 3120 @ 4...20V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge immunity:\u003c\/strong\u003e IEC1000-4-5: 1kV galvanic gun\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical overall accuracy:\u003c\/strong\u003e ¡À1.17% full scale @ -20...65 ¡ãC (Only applicable to Series B I\/O modules.), ¡À0.5% full scale @ 25 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage input protection:\u003c\/strong\u003e -30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Shipping: 240 g (0.53 lbs.) approximately (with cartoon)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":70974149198077,"sku":"1762-IF2OF2","price":289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/99115443f06631978b556061bb69763b_8c6aa626-6d9c-41e2-999f-e9a0382cf983.jpg?v=1785384229","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1762-if2of2-industrial-automation-component","provider":"Lianyou PLC","version":"1.0","type":"link"}